• Title/Summary/Keyword: 규격서

Search Result 473, Processing Time 0.033 seconds

A study on the location of microphones in measurement considering the frequency characteristics of elevator noise in households (세대 내 승강기 소음 주파수특성을 고려한 측정 시 마이크로폰 위치에 관한 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.124-132
    • /
    • 2023
  • When the building becomes high, the number of households increases and they are adjacent to the elevator. So, frequency of use of elevators will increase. Elevator noise is bound to increase in the future. However, there are currently no legal standards for elevator noise or measurement and evaluation methods that can clearly measure elevator noise in Korea. Although some methods for measuring elevator noise are presented in KS F ISO 16032, this standard is not a standard established for elevator noise. It is a standard that integrates the overall measurement method of building equipment and equipment, and the position of the microphone is selected by the experimenter during measurement. Elevator noise is characterized by a low sound pressure level as the noise in the mid-low frequency band is important. However, even today, complaints from residents about elevator noise are increasing. In this study, the position of the microphone that can most sensitively pick up the elevator noise when measuring the elevator noise was studied. According to the distance from the wall and the height from the floor, a total of 9 microphone positions were measured and analyzed. As a result of the experiment, it was confirmed that the elevator noise has a very high influence in the 63 Hz band. The measured value at the center point was identified as a factor that lowered the overall elevator noise level value.

Reviewing the Operation of the Navy Safety Management System and Its Direction (해군 안전관리체계 운영에 대한 검토 및 발전 방향 고찰)

  • Jeongwoo Han;Kijae Kim;Wonyoung Lee;Kyoshik Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.859-868
    • /
    • 2023
  • Purpose: In order to enhance safety, the Korea Navy is making efforts to introduce a safety and health management system and to develop a risk assessment system, while safety accidents keeps occurring. A development plan was proposed through an inspection of the Safety Management System(SMS). Method: To diagnose the Korea Navy's safety management system, changes in the safety environment, documentation system, and safety and health management system operation were reviewed, points to be improved were found, and improvement directions were derived. Result: There is a need for an SMS standard that can present the Korea Navy's safety policy and safety management direction, and a safety program that provides guidelines for implementing it in a standardized manner. To this end, we were able to confirm the feasibility of linking the requirements of the US Navy's SMS and the international standard ISO 45001 standard together with the Korea Navy's safety management system. Conclusion: The Korea Navy's safety management system needs to clearly present safety policies and standards, and have public confidence and effectiveness in safety work through a standard program that can implement them, and for this, the development of a Navy SMS is necessary.

Recent Trends in Cryptanalysis Techniques for White-box Block Ciphers (화이트 박스 블록 암호에 대한 최신 암호분석 기술 동향 연구)

  • Chaerin Oh;Woosang Im;Hyunil Kim;Changho Seo
    • Smart Media Journal
    • /
    • v.12 no.9
    • /
    • pp.9-18
    • /
    • 2023
  • Black box cryptography is a cryptographic scheme based on a hardware encryption device, operating under the assumption that the device and the user can be trusted. However, with the increasing use of cryptographic algorithms on unreliable open platforms, the threats to black box cryptography systems have become even more significant. As a consequence, white box cryptography have been proposed to securely operate cryptographic algorithms on open platforms by hiding encryption keys during the encryption process, making it difficult for attackers to extract the keys. However, unlike traditional cryptography, white box-based encryption lacks established specifications, making challenging verify its structural security. To promote the safer utilization of white box cryptography, CHES organizes The WhibOx Contest periodically, which conducts safety analyses of various white box cryptographic techniques. Among these, the Differential Computation Analysis (DCA) attack proposed by Bos in 2016 is widely utilized in safety analyses and represents a powerful attack technique against robust white box block ciphers. Therefore, this paper analyzes the research trends in white box block ciphers and provides a summary of DCA attacks and relevant countermeasures. adhering to the format of a research paper.

Correction of positional change of frontal cephalometric landmarks caused by vertical head rotation (두부의 수직회전 시 정모두부방사선사진상의 계측점 변화와 이의 보정)

  • Kim, Mi-Young;Lee, Kyung-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.98-111
    • /
    • 2011
  • Objective: Superimposition of frontal cephalograms cannot be performed when the cephalograms are taken with different vertical head rotations. The purpose of the present study was to evaluate the validity of correcting the positional change of frontal cephalometric landmarks caused by vertical head rotation. Methods: In 30 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle. Geometric principles of radiography were used to calculate the possible vertical and horizontal landmark changes if the head should be rotated down $5^{\circ}$ about an ear rod axis. The calculated changes were then compared with cephalometric changes measured on frontal cephalogram actually taken with the head rotated down $5^{\circ}$. Results: When the frontal cephalograms were taken with the head rotated down $5^{\circ}$ about an ear rod axis, significant changes in the vertical position of the landmarks occurred, particularly in the landmarks located farther anteriorly from the ear rod axis. The comparison of calculated changes and real cephalometric changes showed that the differences were less than 0.4 mm in the vertical direction and less than 0.2 mm in the horizontal direction. The differences between calculated and real changes were smaller in the landmarks less affected by vertical head rotation. Conclusions: Even when frontal cephalograms are taken at different vertical head rotations, the concomitant changes in the position of the landmarks can be corrected through calculation using the geometric principle of radiography as long as frontal and lateral cephalograms are taken perpendicular to each other.

Research for Application of Interactive Data Broadcasting Service in DMB (DMB에서의 양방향 데어터방송 서비스도입에 관한 연구)

  • Kim, Jong-Geun;Choe, Seong-Jin;Lee, Seon-Hui
    • Broadcasting and Media Magazine
    • /
    • v.11 no.4
    • /
    • pp.104-117
    • /
    • 2006
  • In this Paper, we analyze the application of Interactive Data Broadcasting in DMB(Digital Multimedia Broadcasting) in the accordance with convergence of service and technology. With the acceleration of digital convergence in the Ubiquitous period substantial development of digital media technology and convergence of broadcasting and telecommunication industry are being witnessed. Consequently these results gave rise to newly combined-products such as DMB(Digital Multimedia Broadcasting), WCDMA(Wide-band code division multiple access), Wibro(Wireless Broadband Internet), IP-TV (Internet protocol TV) and HSDPA(High speed downlink packet access). The preparatory stage for the implementation of Interactive Data Broadcasting Service will be reached by the end of December, 2006. DMB is the first result of a successful convergence service between Broadcasting and Telecommunication in new media era. Multimedia technology and services are the core elements of DMB. The Data Broadcasting will not only offer various services of interactive information such News, Weather, Broadcasting Program etc, but also be linked with characteristic function of mobile phone such as calling and SMS(Short Message Service) via Return Channel.

Regional load deflection rate of multiloop edgewise archwire (Multiloop edgewise arch wire의 부위별 하중변형률)

  • Kim, Byoung-Ho;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.673-688
    • /
    • 1999
  • This study was conducted in order to analyze the mechanical characteristics of multiloop edgewise archwire (MEAW). The purposes were 1) to compare load deflection rate (LDR) of MEAW with that of various other arch wires in the individual interbracket span, 2) to compare the wire stiffness in the interbracket span with that in the multi-L-loop region (the span from distal border of the bracket of the lateral incisor to the mesial border of the buccal tube of the second molar), and 3) to verify the experimental results with theoretically derived formula. The single L-loops of five different horizontal lengths and multi-L-loops for the upper and lower arches were made out of .$016\times.022$ permachrome stainless steel wire. Straight segment of plain stainless steel, TMA and NiTi wire of the same dimension were prepared. The LDR was measured using Instron model 4466 with the load cell of 50N capacity at cross head speed of 1.0mm/min, and maximum deflection of 1.0mm. Five specimens were tested under each experimental condition. The wire stiffness number for each interbracket region and multi-L-loop region was calculated from the LDR and the interbracket spans. By dividing the theoretical model of multi-L-loop into 35 linear segments, the energy stored in each segment was obtained. Then the LDR and wire stiffness of single L-loop and multi-L-loop were calculated and compared. The findings were as follows : 1) The average LDR of MEAW in the individual interbracket region was 1/1.53 of that of the NiTi,1/2.47 of TMA and 1/5.16 of the plain stainless steel wire. 2) The wire stiffness of MEAW in the multi-L-loop region was 1.53 times larger than that in the interbracket region, and the LDR was almost twice as large as that of NiTi in that region. 3) According to the theoretically derived equation, the wire stiffness of the single L-loop was lower than that of multi-L-loop. The results of this study suggest that MEAW has the unique mechanical Property which could allow individual tooth movement and transmit elastic force effectively through the entire arch wire.

  • PDF

Flow Resistance and Modeling Rule of Fishing Nets -2. Flow Resistance of Bag Nets- (그물어구의 유수저항과 모형수칙 -2. 자루형 그물의 유수저항-)

  • KIM Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.2
    • /
    • pp.194-201
    • /
    • 1995
  • In order to make clear the resistance of bag nets, the resistance R of bag nets with wall area S designed in pyramid shape was measured in a circulating water tank with control of flow velocity v and the coefficient k in $R=kSv^2$ was investigated. The coefficient k showed no change In the nets designed in regular pyramid shape when their mouths were attached alternately to the circular and square frames, because their shape in water became a circular cone in the circular frame and equal to the cone with the exception of the vicinity of frame in the square one. On the other hand, a net designed in right pyramid shape and then attached to a rectangular frame showed an elliptic cone with the exception of the vicinity of frame in water, but produced no significant difference in value of k in comparison with that making a circular cone in water. In the nets making a circular cone in water, k was higher in nets with larger d/l, ratio of diameter d to length I of bars, and decreased as the ratio S/S_m$ of S to the area $S_m$ of net mouth was increased or as the attack angle 9 of net to the water flow was decreased. But the value of ks15m was almost constant in the region of S/S_m=1-4$ or $\theta=15-90^{\circ}$ and in creased linearly in S/S_m>4 or in $\theta<15^{\circ}$ However, these variation of k could be summarized by the equation obtained in the previous paper. That is, the coefficient $k(kg\;\cdot\;sec^2/m^4)$ of bag nets was expressed as $$k=160R_e\;^{-01}(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})^{1.6}$$ for the condition of $R_e<100$ and $$k=100(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})^{1.6}$$ for $R_e\geq100$, where $S_n$ is their total area projected to the plane perpendicular to the water flow and $R_e$ the Reynolds' number on which the representative size was taken by the value of $\lambda$ defined as $$\lambda={\frac{\pi d^2}{21\;sin\;2\varphi}$$ where If is the angle between two adjacent bars, d the diameter of bars, and 21 the mesh size. Conclusively, it is clarified that the coefficient k obtained in the previous paper agrees with the experimental results for bag nets.

  • PDF

Relationships between Texture and Physical Properties of Jurassic Unagsan and Cretaceous Sogrisan Granites (쥬라기 운악산 및 백악기 속리산 화강암류의 조직과 물성과의 관계)

  • Yun Hyun-Soo;Park Deok-Won;Hong Sei-Sun;Kim Ju-Yong;Yang Dong-Yoon;Chang Soobum
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.169-184
    • /
    • 2005
  • Unagsan and Sogrisan granites are widely distributed in the northern Gyeonggi massif and middle Ogcheon belt, respectively, and they show different petrologic characteristics as follows. The former has compact textures and light grey colors, and the latter has spotted miarolitic textures and pink colors. Most of the samples selected for tests are fresh and coarse-grained. And bored core samples were prepared so that they are vertical to the rift plane. The results of modal analysis show that Unagsan granite has significantly higher quartz and plagioclase contents (Qz+Pl) than Sogrisan granite. In contrast, alkali feldspar content (Af) of Sogrisan granite is much higher than that of Unagsan granite. Therefore, it is believed that the light grey colors of Unagsan granite are due to relatively high Qz+Pl, and the pink colors of Sogrisan granite are caused by higher Af. Fractures in Sogrisan granite have strongly perpendicular strike patterns and more dip values close to vertical compared with the fractures in Unagsan granite. Results of the fracture pattern analysis suggest that the Sogrisan granite has better potential to produce dimension stones than the Unagsan granite. However, miarolitic textures often found in the Sogrisan granite may be one of the factors reducing the granite quality. The Unagsan and Sogrisan granites have similar specific gravity values of 2.60 and 2.57, respectively. Absorption ratios and porosity values of Sogrisan granite are higher than those of Unagsan granite, and they shows linearly positive correlations. Compressive and tensile strengths of the Unagsan granite are generally higher than those of Sogrisan granite. These differences and variation trends found in physical properties of Unagsan and Sogrisan granite can be explained by the differences in the textures of Unagsan and Sogrisan granites, namely compact and miarolitic textures respectively. For Unagsan granite, compressive and tensile strengths are negatively correlated with porosity but for Sogrisan granite no specific correlations are found. This is probably due to the irregular dispersion patterns of miarolitic textures formed during the later stages of magmatic processes. Contrary to the trends found in absorption ratios, both granites have similar values of abrasive hardness, which can be explained by higher Qz+Af of the Sogrisan granite than those of the Unagsan granite and that quartz and alkali feldspar have relatively larger hardness values. For Sogrisan granite, compressive strength shows slightly positive correlations with Qz+Af+Pl and negative correlations with biotite and accessory mineral contents (Bt+Ac).

Alteration of Anaerobic Bacteria and S. mutans Count in Oral Cavity after Occlusal Stabilization Appliance Use (교합안정장치 사용에 따른 구강 내 혐기성 세균과 S. mutans의 변화)

  • Byun, Jin-Seok;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.375-381
    • /
    • 2007
  • Occlusal stabilization appliance is one of the most common treatment option for management of temporomandibular disorders. It acts in oral cavity for several hours per day, and usually it will take at least 6 months to 2 years of total wearing periods to take a treatment goal. In the oral cavity, occlusal stabilization appliance, unintentional manner, is able to acts as a reservoir of bacteria and protect bacteria from saliva and oxygen. This condition is so favorable to many bacteria such as S. mutans and other anaerobes, usually have been reported as causative factors of dental caries, periodontal disease and oral malodor. In this study, we investigated anaerobic bacteria and S. mutans count before and after occlusal stabilization appliance use to evaluate the possible role of occlusal stabilization appliance as protector of these bacteria. Four men(average 27.5 years) wore maxillary occlusal stabilization appliance at each night(average 9 hours) for 5 days. we swabbed saliva-plaque mixed sample at 3 different site(maxillary left 2nd molar, maxillary left central incisor, mandibular left 2nd molar) before and after occlusal stabilization appliance use. Each samples were plated in (1) anaerobic blood agar medium, (2) selective S. mutans medium(MS-MUTV) and incubated in anaerobic chamber($CO^2$ 10%, $37^{\circ}C$) for 72 hours. Each bacterial colony forming unit(CFU) were counted with naked eyes. From obtained data, we can conclude as follows: 1. There was some changes about anaerobic bacteria and S. mutans count in oral cavity after occlusal stabilization appliance use. 2. The number of anaerobic bacteria was significantly increased at maxillary 2nd molar(P=0.003), maxillary central incisor(P=0.020) after occlusal stabilization appliance use compared with before. 3. Occlusal stabilization appliance use itself had indirect effect to increase the number of anaerobic bacteria at other uncovered opponent tooth site. 4. The number of S. mutans was significantly increased at maxillary 2nd molar(P=0.043), maxillary central incisor (P=0.049) after occlusal stabilization appliance use compared with before. 5. Occlusal stabilization appliance use itself had not any effect on the number of S. mutans at other uncovered opponent tooth site.

The Comparison and Index Components in Quality of Salt-Fermented Anchovy Sauces (멸치 액젓의 품질 비교 및 품질 지표성분에 관한 연구)

  • Oh, Kwang-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.487-494
    • /
    • 1995
  • To assay the quality of anchovy sauce, 10 kinds of commercial anchovy sauce(CAS) were purchased from markets and traditional anchovy sauce(TAS) were prepared. And their physicochemical-microbial characteristics were compared. The compositions of CAS were as followed; pH $5.5{\sim}5.7$, salinity $21.0{\sim}23.2%$, VBN $92.8{\sim}305.4\;mg/100g$, total nitrogen $928.0{\sim}1870.9\;mg%$, amino-nitrogen $338.6{\sim}680.3\;mg%$, and acidity $11.58{\sim}24.58\;ml$. The CAS was lower in pH, smaller in contents of VBN, total-N, amino-N and larger in contents of moisture, salinity than TAS. In Hunter values, CAS was generally lower in L, b values whereas higher in a and ${\Delta}E$ values than TAS. Viable cell counts on 0% NaCl-medium of CAS and TAS were $6.4{\times}10^1{\sim}3.0{\times}10^5\;and\;8.7{\times}10^4$, and those on 2.5% NaCl-medium were $0.8{\times}10^2{\sim}2.2{\times}10^5\;and\;1.6{\times}10^4{\sim}4.5{\times}10^5$, respectively. These viable cell counts in CAS and TAS were gradually decreased according to storage time. In composition of extractives, total free amino acid contents of CAS and TAS were $5498.5{\sim}12123.8\;mg%$, 12797.9 mg%, and these contents were gradually decreased during storage. The major amino acids were found glutamic acid, alanine and leucine in CAS, and alanine, glutamic acid, leucine and valine in TAS. Also contents of hypoxanthine, TMAO, TMA in CAS and TAS were shown $86.4{\sim}161.2\;mg%,\;51.6{\sim}99.2\;mg%,\;23.2{\sim}42.9\;mg%$ and 103.7 mg%, 128.8 mg%, 55.8 mg%, respectively. We may conclude from the results of present experiments that parts of tested CAS were somewhat putrefied and there was a great difference in the quality compared with TAS, whereas TAS maintained good conditions for preserving the quality until storage 2 years.

  • PDF