• Title/Summary/Keyword: 귀반사

Search Result 21, Processing Time 0.034 seconds

Database Utilization for Ear Reflex Education (귀 반사 요법 교육을 위한 데이터베이스 활용)

  • Choung, Hye-myoung
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.07a
    • /
    • pp.323-324
    • /
    • 2015
  • 본 논문에서는 보완대체요법 중 귀 반사 요법을 컴퓨터를 활용하여 데이터베이스화하여 쉽게 교육하고 누구나 원하는 증상별 처치를 빠르게 검색하고 정확한 위치에 첨압 할 수 있으며 귀 반사 기본 자료, 인체상응 관계도, 첨압 관련 리포트 및 증상별 처치 리포트 등을 인쇄로도 가능하여 민간인들도 쉽게 활용할 수 있을 것으로 사료된다.

  • PDF

A Study of The Database System Design for The Ear Reflex Therapy Utilization

  • Choung, Hye-Myoung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.3
    • /
    • pp.43-50
    • /
    • 2020
  • In this paper, we propose an efficient dynamic workload balancing strategy which improves the performance of high-performance computing system. The key idea of this dynamic workload balancing strategy is to minimize execution time of each job and to maximize the system throughput by effectively using system resource such as CPU, memory. Also, this strategy dynamically allocates job by considering demanded memory size of executing job and workload status of each node. If an overload node occurs due to allocated job, the proposed scheme migrates job, executing in overload nodes, to another free nodes and reduces the waiting time and execution time of job by balancing workload of each node. Through simulation, we show that the proposed dynamic workload balancing strategy based on CPU, memory improves the performance of high-performance computing system compared to previous strategies.

A Study for the Norms of Audiometric Tests in Koreans (정상한국인의 청력검사치에 관한 연구)

  • 오혜경;서장수;이근해;김희남;김영명;권영화;서옥기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.1-38
    • /
    • 1981
  • Currently in the otologic field, there are various methods of special audiometric examinations, such as, tone decay, SISI, and impedance audiometry and only a few studies has been done in these fields sporadically in Korea. The purpose of this paper is to establish norms of various special audiometric tests, so we have performed the special audiometric tests on 100 male medical students in good physical condition and the follow results were obtained. 1. All cases showed over 90% of PB scores. The mean and its 2 S.D. were 98$\pm$4.9% in the right ear and 97$\pm$5.6% in the left ear. 2. The mean and its 2 S.D. of MCL(most comfortable level) were 45$\pm$15.4 dB in the right ear and 46$\pm$17.9 dB in the left ear, and its range was 12$\pm$12.2 dB in the right ear and 13$\pm$12.6 dB in the left ear. 3. The mean and its 2 S.D. of UCL (uncomfortable level) were 102$\pm$7.9 dB in the right ear and 102$\pm$7.9 dB in the left ear and about an half in cases showed over 106 dB of UCL. 4. In 95% of cases, SISIs(short increment sensitivity index) at 1, 000 Hz and 4000 Hz was below 45% in the right ear in both frequencies and below 55% and 75% in the left ear, respectively. 5. In 95% of cases, tone decays at 2, 000 Hz and 4, 000 Hz was below 10 dB in both ears. 6. The difference between SRT and PTA (speech reception threshold minus pure tone average) was 4$\pm$9.2 dB in the right ear and 4$\pm$10.0 dB in the left ear. 7. The dynamic range(uncomfortable level minus speech reception threshold) was 98$\pm$13.5 dB in the right ear and 99$\pm$13.5 dB in the left ear. We had trouble in estimating the dynamic range in about an half in cases, in which we couldn't estimate the UCL with our conventional audiometry. 8. The results of impedance audiometric tests were as follow: A. In the tympanogram, all cases were of A type with one exception of B type in the left ear. The mean and its 2 S.D. of its peak level were 22.8$\pm$32.94mm $H_2O$ in the right ear and 23.9$\pm$29. 81mm $H_2O$ in the left ear. B. The mean and its 2 S.D. of the compliance were 0.6$\pm$0.54cc in the right ear and 0.6$\pm$0.53cc in the left ear. C. The results of stapedial reflex: a. The mean and its 2 S.D. of the controlateral stapedial reflex at 500Hz, 1, 000Hz, 2, 000Hz, 4, 000Hz were 99$\pm$17.7 dB, 87$\pm$14.4 dB, 79$\pm$13.7 dB, 77$\pm$20.0 dB in the right ear and 99$\pm$15.9 dB, 88$\pm$13.9 dB, 79$\pm$13.7 dB, 77$\pm$21.3 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wasn't generated in 6 cases in the right ear and 11 cases in the left ear. b. The mean and its 2 S.D. of the ipsilateral stapedial reflex at 1, 000Hz, and 2, 000Hz were 89$\pm$16.3 dB, 82$\pm$15.9 dB in the right ear and 89$\pm$18.0 dB, 83$\pm$18.9 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wans't generated in 1 case in the right ear and 2 cases in the left ear. 9. Eustachian tube function using with impedance audiometry was malfunctioned in21 cases depending on the tested pressure and the range of peak level of tympanogram was 14$\pm$26.9mm $H_2O$(tested pressure:+250mm $H_2O$), 8$\pm$21.9mm $H_2O$ (tested pressure:-250mm $H_2O$) in the right ear and 11 cases depending on the tested pressure and the range of the peak level of tympanogram was 12$\pm$22.5mm $H_2O$ (tested pressure: +250 mm $H_2O$, 9$\pm$17.3mm $H_2O$(tested pressure: -250mm $H_2O$) in the left ear.

  • PDF

Relation between sound pressure level and auditory distance perception in anechoic room (무향실에 있어서의 음압레벨과 거리정위와의 관계)

  • Kim, Hae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1201-1206
    • /
    • 2009
  • According to a lot of investigations, distance perception is influenced by many important cues such as sound pressure level, reflections from the room surface, binaural difference (ITD and ILD), a kind of sound source, and head related transfer functions (HRTF). Two psychoacoustical experiments on auditory distance perception were conducted to examine the effectiveness of the sound pressure level loudness as one of the physical cues in the auditory distance perception under a constant loudspeaker's output level and a constant sound level at the subject's position in the absence of reflections in an anechoic room. Our experimental results showed that the perceived distance of sound image is closer than actual sound source distance with the constant loudspeaker's output level and the constant sound level. Futhermore, the perceived distance of a sound image with constant sound level increased when the actual distance increases up to approximately 2 m while the perceived distance saturated when the sound source distance exceed 2 m. On the other hand, when the condition of loudspeaker's output level was kept constantly, the perceived distance of sound image increased up to around 3m, longer than the conditions of constant sound level at the subject's position. We found that the change in the loudness as a function of distance plays an important role in the auditory distance perception in the absence of reflections..

위성통신용 수신기의 설계

  • 정우영;백정기;최부귀
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 1996.11a
    • /
    • pp.184-195
    • /
    • 1996
  • 본 논문에서는 게이트의 길이가 0.25㎛인 GaAs HEM를 이용하여 11.7㎓-12.2㎓ 대역 위성통신용 수신기를 설계하였다. 설계된 수신기의전체이득은 38㏈이상, 잡음지수 1.8㏈이하, 입출력단의 반사손실은 -10㏈이하를 보였다. 수신기는 저잡음증폭기(LNA), 중간주파수증폭기(IFA), 믹서, 국부발진기(LO)로 구성되어 있으며 LO 주파수와 IF 주파수는 각각 10.75㎓와 0.95㎓-1.45㎓이고 칩의 크기는 1.7㎜×2.5㎜이다.

  • PDF

위성통신용 수신기의 설계

  • 정우영;백정기;최부귀
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.1 no.1
    • /
    • pp.119-233
    • /
    • 1996
  • 본 논문에서는 게이트의 길이가 0.25$\mu\textrm{m}$dlsGaAs HEMT(High Electron Mobility Transistor)를 이용하여 11.7GHz-12.2GHz 대역 위성통신용 수신기를 설계하였다. 설계된 수신기의 전체이득은 38dB 이상, 잡음지수 1.8dB 이하, 입출력단의 반사손실은 -10dB 이하를 보였다. 수신기는 저잡음증폭기(LNA), 중간주파수증폭기(IFA) , 믹서(Mixer), 국부발진기(LO) 로 구성되어 있으며 LO 주파수와 IF 주파수는 각각 10.75GHz 와 0.95GHz-1.45GHz이고 칩의 크기는 1.7mm $\times$2.5mm이다.

  • PDF

위성통신용 수신기의 설계

  • 정우영;백정기;최부귀
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1996.10a
    • /
    • pp.184-195
    • /
    • 1996
  • 본 논문에서는 게이트의 길이가 0.25um인 GaAs HEMT를 이용하여 11.7GHz -12.2GHz 대역 위성통신용 수신기를 설계하였다. 설계된 수신기의 전체이득은 38dB 이상, 잡음지수 1.8dB 이하, 입출력단의 반사손실은 -10dB 이하를 보였다. 수신기는 저잡음증폭기(LNA), 중간주파수증폭기(IFA) , 믹서, 국부발진기(LO) 로 구성되어 있으며 LO 주파수와 IF 주파수는 각각 10.75GHz 와 0.95GHz-1.45GHz이고 칩의 크기는 1.7mm $\times$2.5mm이다.

Measurement and analysis of the near-field HRTFs for virtual audio enhancement (가상음장 재현을 위한 근거리 머리전달함수 측정 및 해석)

  • Shin Ki H.;Park Youngjin
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.335-338
    • /
    • 2004
  • 효과적인 가상음장 재현을 위한 머리전달함수(Head Related Transfer Function: HRTF) 측정 시도는 1994년에 이루어진 MIT의 Bill Gardner에 의한 KEMAR 머리전달 함수 측정 이후 이미 여러 차례에 걸쳐 이루어졌다. 그러나 대부분의 시도는 음원이 머리중심점에서 1 m 이 후에 위치한 원거리에 국한되었고 음원이 1 m나 그 이내에 위치한 근거리에서의 측정은 스피커에서 반사된 음파가 dummy head 나 피험자의 귀에 다시 들어가는 것을 막기 어려워 시도된바가 적으며 data 도 공개되지 않은 것이 현 실정이다. 음원이 머리중심점에서 1 m 보다 가까운 거리에 있는 경우 머리전달함수의 특성은 고도와 방위뿐만 아니라 거리에도 영향을 받는 것으로 알려져 있으며, 이를 알아보기 위해 무향실에 B&K HATS (Head and Torso Simulator)를 설치하고 단극음원에 가까우며 반사가 적은 스피커를 따로 제작하여 근거리 머리 전달함수를 측정하였고 이를 분석하였다.

  • PDF

A Study on the Antenna PIM Measurement in Anechoic Chamber (전자파무반사실에서의 안테나 PIM 측정에 관한 연구)

  • 김진태;조인귀;정명영;최태구
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1167-1174
    • /
    • 2001
  • Antenna PIM(Passive Intermodulation) level measurement results are rarely credited due to the external signal receiving characteristics of antenna, and seriously affected by the external PIM sources such as anechoic chamber absorber and antenna tower. In this paper, antenna PIM model for the Reflect PIM measurement method is presented. Through the null point phenomena of the PIM level obtained by antenna PIM model simulations and experimental results, we concluded that antenna PIM level measurements are greatly affected by the PIM level generated on the anechoic chamber absorber and the path differences of PIM signal reflected to the antenna.

  • PDF

Change Analysis of Intensity and Speed According to Stimulating the Lungs Reflex Point Based on Auricular Acupuncture (이침요법(耳針療法) 기반의 폐 반사점 자극에 따른 음성 크기 및 속도 변화 분석)

  • Seo, Youn-Taek;Yoo, Hwang-Jun;Cho, Dong-Uk;Ka, Min-Kyoung;Kim, Bong-Hyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.900-903
    • /
    • 2012
  • 현대사회의 의료 시술 중 부작용이 거의 없으며 배우기 쉬워 일상적으로 널리 사용되고 있는 의료형태를 대체의학이라 한다. 많은 선진국에서 미래형 의료 서비스로 대체의학에 관한 연구를 활발히 진행하고 있다. 대체의학은 종류가 많지만 그 중 귀에 몸의 각 부위가 상응하는 반사점이 있으며 이를 자극하여 치료하는 형태를 이침요법(耳針療法)이라 한다. 본 논문에서는 이러한 이침요법(耳針療法)을 사용하여 폐에 상응하는 이혈 반사점을 자극하였을 때 음성의 변화를 분석하는 실험을 수행하였다. 이를 위해 폐 이혈(耳穴) 자극 전과 후의 음성을 수집하고 기존 연구를 기반으로 폐와 연관성이 있는 음성분석 요소인 발화속도, Intensity 기술을 적용하여 변화 지표를 측정하고 이를 분석하여 이혈요법의 효과를 입증하는 연구를 수행하였다.