• 제목/요약/키워드: 권고

검색결과 1,709건 처리시간 0.027초

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • 제23권4호
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

The Evaluations of Phoria and AC/A Ratio by Watching 3D TV at Near (3D TV 근거리 시청에 따른 사위도와 조절성폭주비 평가)

  • Son, Jeong-Sik;Kim, Dong-Su;Kim, Jung-Ho;Kim, Jae-Do;Hamacher, Alaric;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제20권3호
    • /
    • pp.319-324
    • /
    • 2015
  • Purpose: This study was designed to evaluate the changes of phoria and calculated AC/A ratio, and their recovery time points by watching 3D television (3D TV). Methods: 50 subjects (male 30, female 20) of 20s to 40s ages who can watch 3D, were measured phoria using a Howell phoria card at 3 m for distance and 40 cm for near. The phoria was evaluated before watching 3D TV and every 10 minutes from starting of watching 3D TV for 30 minutes, and every 5 minutes after finishing of watching 3D TV for 30 minutes again. Results: For the distance phoria during and after watching 3D TV, it was increased to more exophoria $-0.98{\pm}1.37{\Delta}$ (prism diopters) after 10 minutes from starting of 3D TV watching (p=0.063) and increased to more exophoria $-1.00{\pm}1.28{\Delta}$ after 30 minutes (p=0.024), and started to decrease after finishing of watching 3D TV and recovered to the level of before 3D TV watching ($-0.78{\pm}1.11{\Delta}$) after 20 minutes (p=0.32) with comparing to phoria of before watching 3D TV ($-0.80{\pm}1.12{\Delta}$). For the near phoria, it was also increased to more exophoria $-5.71{\pm}4.45{\Delta}$ after 10 minutes from starting of watching 3D TV (p=0.000) and $-6.58{\pm}4.36{\Delta}$ after 30 minutes (p=0.000), and started to decrease after finishing of watching 3D TV and recovered to the level of before watching 3D TV after 20 minutes ($-4.34{\pm}3.67{\Delta}$) (p=0.32) with comparing to the phoria of before watching 3D TV ($-4.36{\pm}3.66{\Delta}$). AC/A ratio was decreased from $4.92{\pm}1.17{\Delta}/D$ for before 3D TV watching to $4.11{\pm}1.50{\Delta}/D$ for after 30 minutes from starting of watching 3D TV (p=0.000), and increased after the end of watching 3D TV and recovered to the level of before 3D TV watching ($4.93{\pm}1.18{\Delta}/D$) after 25 minutes (p=0.598). Conclusions: During watching 3D TV at near, it showed a tendency of convergence insufficiency by decrease of calculated AC/A ratio as result that exophoria at near was higher increased than exophoria at distance. However, the increased exophoria at both near and distance was recovered to the level of base line after 25 minutes from the end of watching 3D TV. Through this study, it seems to need rational proposals of advice for watching 3D TV.

The Precision Test Based on States of Bone Mineral Density (골밀도 상태에 따른 검사자의 재현성 평가)

  • Yoo, Jae-Sook;Kim, Eun-Hye;Kim, Ho-Seong;Shin, Sang-Ki;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제13권1호
    • /
    • pp.67-72
    • /
    • 2009
  • Purpose: ISCD (International Society for Clinical Densitometry) requests that users perform mandatory Precision test to raise their quality even though there is no recommendation about patient selection for the test. Thus, we investigated the effect on precision test by measuring reproducibility of 3 bone density groups (normal, osteopenia, osteoporosis). Materials and Methods: 4 users performed precision test with 420 patients (age: $57.8{\pm}9.02$) for BMD in Asan Medical Center (JAN-2008 ~ JUN-2008). In first group (A), 4 users selected 30 patient respectively regardless of bone density condition and measured 2 part (L-spine, femur) in twice. In second group (B), 4 users measured bone density of 10 patients respectively in the same manner of first group (A) users but dividing patient into 3 stages (normal, osteopenia, osteoporosis). In third group (C), 2 users measured 30 patients respectively in the same manner of first group (A) users considering bone density condition. We used GE Lunar Prodigy Advance (Encore. V11.4) and analyzed the result by comparing %CV to LSC using precision tool from ISCD. Check back was done using SPSS. Results: In group A, the %CV calculated by 4 users (a, b, c, d) were 1.16, 1.01, 1.19, 0.65 g/$cm^2$ in L-spine and 0.69, 0.58, 0.97, 0.47 g/$cm^2$ in femur. In group B, the %CV calculated by 4 users (a, b, c, d) were 1.01, 1.19, 0.83, 1.37 g/$cm^2$ in L-spine and 1.03, 0.54, 0.69, 0.58 g/$cm^2$ in femur. When comparing results (group A, B), we found no considerable differences. In group C, the user_1's %CV of normal, osteopenia and osteoporosis were 1.26, 0.94, 0.94 g/$cm^2$ in L-spine and 0.94, 0.79, 1.01 g/$cm^2$ in femur. And the user_2's %CV were 0.97, 0.83, 0.72 g/$cm^2$ L-spine and 0.65, 0.65, 1.05 g/$cm^2$ in femur. When analyzing the result, we figured out that the difference of reproducibility was almost not found but the differences of two users' several result values have effect on total reproducibility. Conclusions: Precision test is a important factor of bone density follow up. When Machine and user's reproducibility is getting better, it’s useful in clinics because of low range of deviation. Users have to check machine's reproducibility before the test and keep the same mind doing BMD test for patient. In precision test, the difference of measured value is usually found for ROI change caused by patient position. In case of osteoporosis patient, there is difficult to make initial ROI accurately more than normal and osteopenia patient due to lack of bone recognition even though ROI is made automatically by computer software. However, initial ROI is very important and users have to make coherent ROI because we use ROI Copy function in a follow up. In this study, we performed precision test considering bone density condition and found LSC value was stayed within 3%. There was no considerable difference. Thus, patient selection could be done regardless of bone density condition.

  • PDF

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • 제25권4호
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • 제32권3호
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • 제33권2호
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제12권3호
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

The Jurisdictional Precedent Analysis of Medical Dispute in Dental Field (치과임상영역에서 발생된 의료분쟁의 판례분석)

  • Kwon, Byung-Ki;Ahn, Hyoung-Joon;Kang, Jin-Kyu;Kim, Chong-Youl;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • 제31권4호
    • /
    • pp.283-296
    • /
    • 2006
  • Along with the development of scientific technologies, health care has been growing remarkably, and as the social life quality improves with increasing interest in health, the demand for medical service is rapidly increasing. However, medical accident and medical dispute also are rapidly increasing due to various factors such as, increasing sense of people's right, lack of understanding in the nature of medical practice, over expectation on medical technique, commercialize medical supply system, moral degeneracy and unawareness of medical jurisprudence by doctors, widespread trend of mutual distrust, and lack of systematized device for solution of medical dispute. This study analysed 30 cases of civil suit in the year between 1994 to 2004, which were selected among the medical dispute cases in dental field with the judgement collected from organizations related to dentistry and department of oral medicine, Yonsei university dental hospital. The following results were drawn from the analyses: 1. The distribution of year showed rapid increase of medical dispute after the year 2000. 2. In the types of medical dispute, suit associated with tooth extraction took 36.7% of all. 3. As for the cause of medical dispute, uncomfortable feeling and dissatisfaction with the treatment showed 36.7%, death and permanent damage showed 16.7% each. 4. Winning the suit, compulsory mediation and recommendation for settlement took 60.0% of judgement result for the plaintiff. 5. For the type of medical organization in relation to medical dispute, 60.0% was found to be the private dental clinics, and 30.0% was university dental hospitals. 6. For the level of trial, dispute that progressed above 2 or 3 trials was of 30.0%. 7. For the amount of claim for damage, the claim amounting between 50 million to 100 million won was of 36.7%, and that of more than 100 million won was 13.3%, and in case of the judgement amount, the amount ranging from 10 million to 30 million won was of 40.0%, and that of more than 100 million won was of 6.7%. 8. For the number of dentist involved in the suit, 26.7% was of 2 or more dentists. 9. For the amount of time spent until the judgement, 46.7% took 11 to 20 months, and 36.7% took 21 to 30 months. 10. For medical malpractice, 46.7% was judged to be guilty, and 70% of the cases had undergone medical judgement or verification of the case by specialists during the process of the suit. 11. In the lost cases of doctors(18 cases), 72.2% was due to violence of carefulness in practice and 16.7% was due to missing of explanation to patient. Medical disputes occurring in the field of dentistry are usually of relatively less risky cases. Hence, the importance of explanation to patient is emphasized, and since the levels of patient satisfaction are subjective, improvement of the relationship between the patient and the dentist and recovery of autonomy within the group dentist are essential in addition to the reduction of technical malpractice. Moreover, management measure against the medical dispute should be set up through complement of the current doctors and hospitals medical malpractice insurance which is being conducted irrationally, and establishment of system in which education as well as consultation for medical disputes lead by the group of dental clinicians and academic scholars are accessible.

Effectiveness of Smoking Prevention Program based on Social Influence Model in the Middle School Students (흡연예방교육에 의한 청소년들의 흡연에 대한 지식 및 태도변화와 흡연량의 감소 효과)

  • Roh, Won-Hwan;Kang, Pock-Soo;Kim, Sok-Beom;Lee, Kyeong-Soo
    • Journal of agricultural medicine and community health
    • /
    • 제26권1호
    • /
    • pp.37-56
    • /
    • 2001
  • This study was conducted to analyze the degree of changes in knowledge and attitude toward smoking and to examine the factors affecting knowledge and attitude for smoking after providing a smoking prevention program based on social influence model for a year to middle school students. Study population consists of 665 subjects of middle school students(aged 14 years) in Gumi city in Kyeongsangbukdo Province. Among them three-hundred sixty-seven students(intervention group) were educated to a smoking prevention program for 1 year from April 1999 to April 2000. School-based four-class program to prevent smoking was developed. The program provides instruction about short and long-term negative physiologic and social consequences of smoking and also discussed the health hazards of smoking, social pressure to smoke, peer norms regarding tobacco use, and refusal skill. A 45-item self-administered structured questionnaire was designed to evaluate the change of knowledge, attitude, smoking rate and the amount of smoking. The instrument was comprised of 11 knowledge items, thirteen attitude item and demographic items. Each scales were created by summing responses to each items within each scales and high scores on the knowledge, attitude, and smoking behavioral intention scales indicated positive responses. Based on the changes before and after the implementation of smoking prevention program between intervention and control group, the change of scores on knowledge were significantly different between the control group and the intervention group(p<0.05) and the change of scores on the attitude toward smoking was significantly different between intervention and control group. The change of smoking rate were not showing a significant difference between two groups but the amount of smoking were significantly reduced in intervention group than control group. In multiple regression analysis on changes of knowledge about smoking, the variables of smoking prevention program education, previous knowledge on smoking and students' school performance were selected the significant variables. In multiple regression to analysis of the factors influencing changes in attitude toward smoking, the variables of smoking prevention program education, previous knowledge on smoking were shown to be significant. The smoking prevention program was effective on change of knowledge and attitude of middle school students. In considering that the policy should be needed to extent of implementation of school-based health education curricula based on social influence model and it would contribute to reduce smoking of students.

  • PDF