• Title/Summary/Keyword: 권고

Search Result 1,709, Processing Time 0.023 seconds

Estimation of the Possible Age for Using Various Types of Inhaler by In-Check Inspiratory Flow Meter(TM) (In-Check Inspiratory Flow Meter(TM)를 사용하여 추정한 다양한 흡입기구의 사용 가능한 연령)

  • Jung, Kyung Hyun;Kim, Sun Ye;Lee, Jun Ho;Kim, Kye Sung;Jang, Yook;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.192-198
    • /
    • 2002
  • Purpose : It is important to select and use kinds of Inhaler appropriate to the age of the patient and severity of symptoms. Several kinds of Inhaler have been developed and recommended according to each inhaler's resistance and usage method. We evaluated the usable age of 4 inhalers (turbulent flow inhalers, multi unit dose inhalers, breath actuated MDI, and autohalers) by measuring peak inspiratory flow(PIF) using $In-Check^{(TM)}$ Inspiratory Flow Meter. Methods : Ninety three patients aged from 3 to 7 years(mean $57{\pm}12.9$ mo.) who had admitted to CHA hospital from July 2000 to April 2001 were enrolled. Study patients were divided into 4 groups according to age : 3-4 years of age(group A, n=31), 4-5 years of age(group B, n=32), 5-6 years of age(group C, n=18), and 6-7 years of age(group D, n=12). Results : Out of total 93 patients, 23(71%), 27(84%), 17(94%) patients of each group A, B, C and all 12 patients of group D could use the 4 types of inhaler through adequated education. In all four groups, height, body weight and age were significantly correlated(P<0.05). Usable age, height and weight of children who can use turbulent flow inhaler(TFI) were each 8 year 7 month old, 144 cm, 32.0 kg, and those of multi unit dose inhaler(MUD) were 2 year 10 month old, 92 cm, 12.0 kg. Also that of breath-actuated MDI were 1 yr 8 months, 83 cm, 8.5 kg and that of autohaler were 2 yr 8 months, 91 cm, 11.0 kg Conclusion : We concluded that the ability to use inhalers correlated with height, weight and age of the patients. Multi unit dose inhalers, Breath actuated MDI and Autohaler are useful after 3 years of age through adequate education.

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Comparison of Treatment Planning on Dosimetric Differences Between 192Ir Sources for High-Dose Rate Brachytherapy (고선량률 근접치료에서 이리듐-192 선원의 선량특성 차이에 관한 치료계획 비교)

  • Yang, Oh-Nam;Shin, Seong Soo;Ahn, Woo Sang;Kim, Dae-Yong;Kwon, Kyung-Tae;Lim, Cheong-Hwan;Lee, Sang Ho;Choi, Wonsik
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.163-170
    • /
    • 2016
  • To evaluate whether the difference in geometrical characteristics between high-dose-rate (HDR) $^{192}Ir$ sources would influence the dose distributions of intracavitary brachytherapy. Two types of microSelectron HDR $^{192}Ir$ sources (classic and new models) were selected in this study. Two-dimensional (2D) treatment plans for classic and new sources were generated by using PLATO treatment planning system. We compared the point A, point B, and bladder and rectum reference points based on ICRU 38 recommendation. The radial dose function of the new source agrees with that of the classic source except difference of up to 2.6% at the nearest radial distance. The differences of anisotropy functions agree within 2% for r=1, 3, and 5 cm and $20^{\circ}$ < ${\theta}$ < $165^{\circ}$. The largest discrepancies of anisotropy functions reached up to 27% for ${\theta}$ < $20^{\circ}$ at r=0.25 cm and were up to 13%, 10%, and 7% at r=1, 3, and 5 cm for ${\theta}$ > $170^{\circ}$, respectively. There were no significant differences in doses of point A, point B, and bladder point for the treatment plans between the new and classic sources. For the ICRU rectum point, the percent dose difference was on average 0.65% and up to 1.0%. The dose discrepancies between two treatment plans are mainly affected due to the geometrical difference of the source and the sealed capsule.

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Indoor air quality(IAQ) in workplace and residential environments has been concern of people. Recently, Ministry of Environment in Korea has recognized the potential risk on the healthy effect related to indoor air pollution at home. Therefore, the purpose of this study was performed to measure the indoor air pollutants of IAQ at different homes and investigate to compare the perception of IAQ recognition at home from questionnaire survey in Seoul. We estimated the IAQ of selected 6 homes based on site region and housing type. The indoor air pollutants and parameters such as temperature, relative humidity, respirable suspended particulate matter($PM_{10}$), formaldehyde(HCHO), total bacteria counts, carbon monooxide(CO) and carbon dioxide($CO_2$) were monitored for summer and winter. In monitoring results, the respirable suspended particulate matter(($PM_{10}$) and indoor airborne bacteria level of home 5 and 6 were higher than the standard of the public $150{\;}{\mu}g/m^3$ and $500{\;}{\mu}g/m^3$, the level formaldehyde(HCHO) was exceed 0.1 ppm of the standard of Korea at all monitored homes. In statistics analysis, we could find a correlation between the building age and the concentration of CO, TBC were significant at 0.01 level and Relative Humidity was significant at 0.05 level for summer. Finally, the important air pollutants of IAQ in home were HCHO and total bacteria counts(TBC). And we performed a questionnaire survey of 500 people about their awareness for the importance of IAQ in our home during same period. In results, all most response of occupant has recognized the importance of IAQ at home. Therefore, it can be concluded that the IAQ of selected 6 home studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems, and the occupants need to be effort to reduce the exposure of sources to undesirable pollutants.

An Evaluation of the Private Security Industry Regulations in Queensland : A Critique (호주 민간시큐리티 산업의 비판적 고찰 : 퀸즐랜드주를 중심으로)

  • Kim, Dae-Woon;Jung, Yook-Sang
    • Korean Security Journal
    • /
    • no.44
    • /
    • pp.7-35
    • /
    • 2015
  • The objective of this article is to inform and document the contemporary development of the private security industry in Queensland Australia, a premier holiday destination that provide entertainment for the larger region. The purpose of this review is to examine the comtemporary development of mandated licensing regimes regulating the industry, and the necessary reform agenda. The overall aim is threefold: first, to chart the main outcomes of the two-wave of reforms since the mid-'90s; second, to examine the effectiveness of changes in modes of regulation; and third, to identify the criteria that can be considered a best practice based on Button(2012) and Prenzler and Sarre's(2014) criteria. The survey of the Queensland regulatory regime has demonstrated that, despite the federal-guided reforms, there remain key areas where further initiatives remain pending, markedly case-by-case utilisation of more proactive strategies such as on-site alcohol/drug testing, psychological evaluations, and checks on close associates; lack of binding training arrangement for technical services providers; and targeted auditing of licensed premises and the vicinity of venues by the Office of Fair Trading, a licensing authority. The study has highlighted the need for more determined responses and active engagements in these priority areas. This study of the development of the licensing regimes in Queensland Australia provides useful insights for other jurisdictions including South Korea on how to better manage licensing system, including the measures required to assure an adequate level of professional competence in the industry. It should be noted that implementing a consistency in delivery mode and assessment in training was the strategic imperative for the Australian authority to intervene in the industry as part of stimulating police-private partnerships. Of particular note, competency elements have conventionally been given a low priority in South Korea, as exemplified through the lack of government-sponsored certificate; this is an area South Korean policymakers must assume an active role in implementing accredited scheme, via consulting transnational templates, including Australian qualifications framework.

  • PDF

The Effects of Dental Hygiene Students' Self-efficacy and Smoking Knowledge on Their Perception on Guidance for Antismoking (치위생과 학생들의 자기효능감과 흡연지식이 금연지도 인식도에 미치는 영향)

  • Ji, Min-Gyeong
    • Journal of dental hygiene science
    • /
    • v.9 no.1
    • /
    • pp.25-34
    • /
    • 2009
  • The present study purposed to survey dental hygiene students who will play important roles in guidance and to utilize the data as basic information for setting the direction of dental hygienists' efficient guidance for antismoking and developing antismoking education programs. For this purpose, a survey was conducted with 400 students at the Department of Dental Hygiene in Daejeon, Jollabuk-do and Jollanam-do during the period from May 19 to June 14 in 2008, and drew conclusions as follows: As to correlations among self-efficacy, smoking knowledge, and perception on guidance for antismoking, positive correlation was observed between self-efficacy and smoking knowledge (r=0.102), between self-efficacy and perception on guidance for antismoking (r=0.272), and between smoking knowledge and perception on guidance for antismoking (r=0.352). As to factors affecting perception on guidance for antismoking, the effect was high in order of perception on smoking, smoking knowledge, and self-efficacy. That is, perception on guidance for antismoking was more positive in those who thought that smoking must not be allowed, those with high smoking knowledge, and those with high self-efficacy. For dental hygienists' clinical activities for efficient prevention of smoking and guidance for antismoking, it is necessary to develop curriculums containing various practical contents.

  • PDF

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

A Definition of Korean Heat Waves and Their Spatio-temporal Patterns (우리나라에 적합한 열파의 정의와 그 시.공간적 발생패턴)

  • Choi, Gwang-Yong
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.5 s.116
    • /
    • pp.527-544
    • /
    • 2006
  • This study provides a definition of heat waves, which indicate the conditions of strong sultriness in summer, appropriate to Korea and intends to clarify long term(1973-2006) averaged spatial and temporal patterns of annual frequency of heat waves with respect to their intensity. Based on examination of the Korean mortality rate changes due to increase of apparent temperature under hot and humid summer conditions, three consecutive days with at least $32.5^{\circ}C,\;35.5^{\circ}C,\;38.5^{\circ}C,\;and\;41.5^{\circ}C$ of daily maximum Heat Index are defined as the Hot Spell(HS), the Heat Wave(HW), the Strong Heat Wave(SHW), and the Extreme Heat Wave(EHW), respectively. The annual frequency of all categories of heat waves is relatively low in high-elevated regions or on islands adjacent to seas. In contrast, the maximum annual frequency of heat waves during the study period as well as annual average frequency are highest in interior, low-elevated regions along major rivers in South Korea, particularly during the Changma Break period(between late July and mid-August). There is no obvious increasing or decreasing trend in the annual total frequency of all categories of heat waves for the study period However, the maximum annual frequencies of HS days at each weather station were recorded mainly in the 1970s, while most of maximum frequency records of both the HW and the SHW at individual weather stations were observed in the 1990s. It is also revealed that when heat waves occur in South Korea high humidity as well as high temperature contributes to increasing the heat wave intensity by $4.3-9.5^{\circ}C$. These results provide a useful basis to help develop a heat wave warning system appropriate to Korea.

Relation Between Degree of Consistency of Elementary Students' Preconceptions on the Brightness of Electric Bulb and Their Cognitive Conflict (전구의 밝기에 대한 초등학생들의 사전개념 일관성 정도와 인지갈등 정도와의 관계)

  • Jung Mee-young;Kim Kung-suk;Kwon Jaesoo
    • Journal of Korean Elementary Science Education
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2005
  • This study was to investigate the elementary students' preconception on the brightness of electric bulb and degree of consistency on their preconceptions. Participants were 160 students of fifth graders in Seoul area. They had already teamed about the brightness of series circuit and parallel circuit of batteries. After they solved six problems in the same context, we provided them a pair of circuit which was an anomalous situation. And then they conducted CCLT (Cognitive Conflict Level Test). Elementary school students showed various preconceptions when they explained the light of bulb of two Simple electric Circuits. Many Students Consistently Showed the Scientific misconceptions like 'the light of bulb of two simple electric circuits was that the more batteries and the fewer bulbs were brighter.' The level of consistency that students presented scientific misconceptions was grouped all of four, such as 'high, middle, low, and nothing.' Therefore the higher scientific achievement they have, the higher consistency they have. As the students had high consistency level, they revealed high cognitive conflict level significantly. This high consistency will help them to change their preconception on the brightness of electric bulb and their cognitive conflict.

  • PDF