• Title/Summary/Keyword: 굴곡각

Search Result 242, Processing Time 0.036 seconds

Biomechanical Alterations in the Lower limb Joints during the Punching Motion of Elderly Women after 12-Weeks of Taekwonaerobics Training (여성노인의 태권에어로빅스 12주 훈련 후 몸통지르기 동작시 하지관절의 생체역학적 변화)

  • Yoo, Sil
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.637-645
    • /
    • 2009
  • The purpose of this study was to investigate the biomechanical alterations in the punching motion of 10 elderly women after 12 weeks of taekwonaerobics training. Seven infrared cameras(Qualisys MCU-240) and 2 force platforms(Kistler-9286AA) were used to acquire raw data. The results were as follows. First, the minimum joint angles of the lower limbs had a statistically significant difference between both the dorsiflexion/plantar flexion(1eft, $p=0.001^*$) and the inversion/eversion(both, $p=0.009^*$, $p=0.04^*$) from the ankle angle. There were differences in abduction/adduction(left, $p=0.04^*$) from the knee angle, as well as internal/external rotation(both, $p=0.07^*$, $p=0.02^*$) from the hip angle. Second, the maximum resultant joint moments of the lower limbs had statistically significant differences in the inversion/eversion moment from the ankle joint(both, $p=0.05^*$, $p=0.05^*$), the abduction/adduction moment(left, $p=0.08^*$) from the knee joint, and the internal/external rotation moment(right, $p=0.09^*$) from the hip joint. Third, the maximum resultant joint powers of the lower limbs had a statistically significant difference both in flexion/extension joint powers(both, $p=0.05^*$, $p=0.01^*$) and in abduction/adduction(both, $p=0.02^*$, $p=0.00^*$) from the hip joint, as well as abduction/adduction(left, $p=0.00^*$) from the knee joint, In conclusion, the elderly women were somewhat changed after 12 weeks of taekwonaerobics training.

Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator (Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석)

  • 이문규;김종민;김동민;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.363-367
    • /
    • 2003
  • Contact area and pressure are important factors which directly influence a life of knee implants. Since implant's mechanical functions should be experimentally evaluated for clinical use, many studies using a knee simulator and a pressure sensor system have been conducted. However it has not been reported that the contact pressure's distribution of a knee implant motion was estimated in real-time during a gate cycle. Therefore. the objective of this study was to analyze the contact pressure distribution for the motion of a joint using the knee simulator and I-scan sensor system. For this purpose, we developed a force-controlled dynamic knee simulator to evaluate the mechanical performance of artificial knee joint. This simulator includes a function of a soft tissue and has a 4-degree-of-freedom to represent an axial compressive load and a flexion angle. As axial compressive force and a flexion angle of the femoral component can be controlled by PC program. The pressure is also measured from I-scan system and simulator to visualize the pressure distribution on the joint contact surfaces under loading condition during walking cycle. The compressive loading curve was the major cause for the contact pressure distribution and its center move in a cycle as to a flexion angie. In conclusion, this system can be used to evaluate to the geometric interaction of femoral and tibial design due to a measured mechanical function such as a contact pressure, contact area and a motion of a loading center.

Anatomical Direct Reduction of Bony Mallet Finger Using Modified-Intrafocal Pinning Technique (변형-내초점 핀 고정술을 이용한 골성 망치 수지의 해부학적 직접 정복)

  • Kang, Sang-Woo;Park, Ji-Kang;Jung, Ho-Seung;Cha, Jung-Kwon;Kim, Kook-Jong
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.248-253
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the clinical results of anatomic reduction of bony mallet finger using modified-intrafocal pinning technique. Methods: From March 2014 to October 2017, 18 patients with bony mallet finger were treated with modified-intrafocal pinning technique. Kirschner-wire was used to directly reduction the bony fragment, and extension block pinning and distal interphalangeal joint fixation were additionally performed to minimize the loss of reduction. Postoperative pain, range of motion, and radiological evaluation were performed. Duration of bone healing, functional recovery and complication rate were evaluated and Crawford's criteria was used to determine functional outcome after surgery. Results: Bone union was achieved in all cases after a postoperative mean of 6 weeks (5-7 weeks). An average of $2.8^{\circ}$ ($0^{\circ}-10^{\circ}$) extension loss occurred in all patients. All patients showed satisfactory joint congruency and reformation of the joint surface, the mean flexion angle of the distal interphalangeal joint at the final follow-up was $72.2^{\circ}$ ($70^{\circ}-75^{\circ}$). According to Crawford's classification, 12 patients (66.7%) were excellent and 6 patients (33.3%) were good. Conclusion: Modified-intrafocal pinning technique is a method of obtaining anatomical bone healing by directly reduction and fixation of the bony fragment. Combined with other conventional percutaneous pinning procedures, it is expected that good results can be obtained if applied to appropriate indications.

Giant Cell Tumor of Tendon Sheath in Hand (Comparative Studies Between Single and Multifocal Lesions) (수부 건초에서 발생한 거대 세포종 (단발성 및 다발성 거대 세포종의 비교))

  • Rhee, Seung-Koo;Kang, Yong-Koo;Bahk, Won-Jong;Yang, Sung-Chul;Shin, Yun-Hack
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.52-60
    • /
    • 2003
  • Purpose: To analyse their end results and also to differentiate the single or multiple giant cell tumor(GCT) of tendon sheath in hand. Materials & Methods: Total 21 cases with GCT of tendon sheath in hand were treated surgically and analyzed their end results with clinically, radiologically and pathologically to allowed for average 16 months after surgical excision. Results: The finger flexor tendons, especially on index and ring finger, involving distal interphalangeal joint and mid-phalanges in fourth decades (average age of 47 years old) were frequently involved, and the mass was not exceed than 2 cm in size, fixed on tendon sheath with rubbery hard tenderness but rare bony involvements except 4 cases of bony erosion and cortical perforation. The three cases with multiple GCT of hand was also combined with familial hypercholesterolemia, and are commonly involved the extensor tendons as well as achilles tendons bilaterally, treated with partial excision because of multiplicity. Average 16 months after surgical excision for single GCT cases was followed and showed the recurrence in 3 cases(3/18,16.7%), treated with wide excision. The single and multifocal GCT are similar in pathologic changes but different soft tissue tumors in their pathogenesis, treatment and prognosis. Conclusion: Incomplete excision of GCT of tendon sheath in hand are thought to be the cause of recurrence, especially in cases with incomplete lesional excision, in multilobular and bony involvement etc. So careful wide excision is necessary to prevent the recurrence.

  • PDF

Clinicopathological Characteristics of Superficially Spreading Early Gastric Cancer (표층 확장형 조기위암의 임상병리학적 특성)

  • Kwon, Sung-Joon;Kim, Hyoung-Ju
    • Journal of Gastric Cancer
    • /
    • v.5 no.4 s.20
    • /
    • pp.288-294
    • /
    • 2005
  • Purpose: Superficially spreading (SS) early gastric cancer (EGC) is characterized by wide horizontal extension without deep vertical invasion. It is a relatively rare form of EGC, and it's clinicopathological (C-P) characteristics are not evident. This study aimed to clarify their C-P characteristics. Materials and Methods: We defined SS EGC as invading less than the submucosal layer that measured more than 60 mm in diameter or wider than $5{\times}5cm \;(25cm^2)$ in width. The C-P characteristics and prognosis were compared between 69 patients with SS EGC and 319 patients with the common type EGC (EGC except SS type). Results: For SS EGC lymph node metastases, Lauren's diffuse type, lymphatic invasion were significantly higher than in common type EGC. In patients with SS EGC, all of the metastatic lymph nodes were anatomically distributed within the paragastric region, with fewer along the left gastric artery and common hepatic artery. In 6 cases of SS EGC with resection marqins less than 10 mm, there was no death during the follow-up period (4 to 13 years after operation) if margins were not involved. Age (>58 yrs), tumor site (upper 1/3), lymph node metastasis, submucosal invasion were statistically significant poor prognostic factor in univariate survival analysis. In multivariate survival analysis, age and lymph node metastasis were independent prognostic factors. However, tumor diameter or width was not a significant prognostic factor. Conclusion: Although SS EGC has histologically distinct properties, gastrectomy with free surgical margins and appropriate lymph node dissection $(D1+{\beta})$ could be a suitable treatment.

  • PDF

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF

The Effect of Sling Exercise on Muscular Strength and Range of Motion in Female Patients who Received Total Knee Replacement (슬링 운동이 무릎관절 전치환술을 시행한 여성 환자의 근력과 관절가동범위에 미치는 영향)

  • Bae, Chang-Hwan;Jung, Yeon-Woo;Lee, Dong-Woo;Cho, Sung-Hyoun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4395-4403
    • /
    • 2014
  • The purpose of study was to compare the effectiveness of sling exercise on the muscle strength and range of motion in female patients who received a total knee replacement. The participants were allocated randomly into 2 groups: sling exercise group (n=15) and control group (n=15). The subjects were evaluated using the Biodex system for the muscle strength test and a goniometer for the range of motion test. The data was analyzed using a paired t-test and independent t-test to determine the statistical significance. As a result, the sling exercise group before and after intervention showed a statistical significance difference in the flexion angle, quadriceps femoris, and hamstring muscle strength. The control group before and after the intervention revealed a statistically significant increase in the flexion & extension angle, quadriceps femoris, and hamstring muscle strength. Muscle strength test and flexion range of motion test in the sling exercise group showed statistical significance differences compared to the control group (p<.05). Therefore, the sling exercise group has a positive influence on the muscle strength and ROM in patients with a total knee replacement.

Shear behavior at the interface between particle and non-crushing surface by using PFC (PFC를 이용한 입자와 비파쇄 평면과의 접촉면에서의 전단 거동)

  • Kim, Eun-Kyung;Lee, Jeong-Hark;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.293-308
    • /
    • 2012
  • The shear behavior at the particle/surface interface such as rock joint can determine the mechanical behavior of whole structure. Therefore, a fundamental understanding of the mechanisms governing its behavior and accurately estimation of the interface strength is essential. In this paper, PFC, a numerical analysis program of discrete element method was used to investigate the effects of the surface roughness on interface strength. The surface roughness was characterized by smooth, intermediate, and rough surface, respectively. In order to investigate the effects of particle shape and crushing on particle/surface interface behavior, one ball, clump, and cluster models were created and their results were compared. The shape of particle was characterized by circle, triangle, square, and rectangle, respectively. The results showed that as the surface roughness increases, interface strength and friction angle increase and the void ratio increases. The one ball model with smooth surface shows lower interface strength and friction angle than the clump model with irregular surface. In addition, a cluster model has less interface strength and friction angle than the clump model. The failure envelope of the cluster model shows non-linear characteristic. From these findings, it is verified that the surface roughness and particle shape effect on the particle/surface interface shear behavior.

A Study on Muscle Architectural and Tissue Compliance of Biceps Brachii in Stroke Patient Based on Elbow Joint Angle (뇌졸중 환자에서 주관절 각도 변화에 따른 상완이두근의 근구조 및 탄성 변화에 관한 연구)

  • Bae, Sea-Hyun;Jeong, Chan-Joo;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5867-5874
    • /
    • 2012
  • The aim of this study was to find on muscle architectural and tissue compliance of biceps brachii in stroke patient based on elbow joint angle. The subjects of this study were twelve hemiplegic adults after stroke with passive range of motion in the elbow from $10^{\circ}$ to $90^{\circ}$ and Modified Ashworth Scale score 1 to 3 were recruited. Ultrasonography and Myotonometer was used to measure biceps brachii muscle pennation angle, fascicle length, and tissue compliance at the rest condition and pennation angle, fascicle length, and tissue compliance of the biceps brachii muscle were measured in the affected and unaffected sides of people after stroke at 9 different elbow angles ranging from $10^{\circ}$ to $90^{\circ}$ at the rest condition. The results of this study, comparisons found that the pennation angles of the affected biceps brachii muscle were significantly larger(p<.05) than the unaffected muscle in the most extended positions($<40^{\circ}$), whereas the affected fascicle lengths were significantly shorter(p<.05) than the unaffected muscle in most flexed positions($>20^{\circ}$), and the affected tissue compliance were significantly lower(p<.05) than the unaffected muscle in most extended positions($<50^{\circ}$) Therefore, pennation angles, fascicle lengths, and tissue compliance were found to be joint-angle-dependent in both the affected and unaffected sides at the rest condition. Suggest that, the results data can be used as a muscle architectural changes and clinical treatment research in stroke patients.

Role of Sand Shoal in the Intertidal Flat Sedimentation, Gomso Bay, Southwestern Korea (서해 곰소만 조간대 퇴적작용에서 모래톱의 역할)

  • Lee, In-Tae;Chun, Seung Soo
    • Journal of the Korean earth science society
    • /
    • v.22 no.2
    • /
    • pp.120-129
    • /
    • 2001
  • A sand shoal (1300 m long and 400 m wide) with an orientation of north-south is formed on the lower tidal flat of Gomso Bay, southwestern coast of Korea. Surface bedforms, sedimentary structures, sedimentation rate, grain size distribution and can-corer sediments have been measured and analysed along the sand shoal proper zone B and its offshore zone A and onshore zone C during the period of 14 months. These three zones can be differentiated based on sedimentological characteristics: A zone - fine sand (3${\varphi}$ mean), linguoid-type ripples, 70 mm/month in sedimentation rate and no bioturbation, B zone - medium sand (2.5${\varphi}$ mean), dunes (4${\sim}$5 m in wavelength), 30 mm/month in sedimentation rate and no bioturbation, and C zone - coarse silt (5${\varphi}$ mean), sinuous-type ripples, 10 mm/month in sedimentation rate and well-developed bioturbation. These characteristics indicate that the zone C represents a relatively low-energy regime environment whereas the zone A corresponds to a relatively high-energy environment. The zone B would play an important role for a barrier to dissipate the approaching wave energy, resulting in maintaining of low-energy conditions in the inner part of Gomso-Bay intertidal flat behind.

  • PDF