Study on the evaluation of sound level testing results of power transformer in IEC standard (변압기 소음측정 결과 산출에 대한 국제표준 동향 고찰)

  • Kim, Sun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.437-438
    • /
    • 2015
  • 전력용 변압기 시험의 여러항목 중 소음은 변압기 자체의 설계 및 함께 사용되는 냉각장치들 관련 고려되는 항목들 중 하나로서 특히 그 설치장소와 관련이 되는 값이다. 전력용 변압기의 소음측정에 관한 표준으로서는 IEC 60076-10 및 IEC 60076-10-1이 있다. IEC TC14 기술위원회는 최근 IEC의 전력용변압기 표준들 중 IEC 60076-10 소음측정 및 IEC 60076-10-1 소음측정지침의 개정안을 완료하였으며 곧 발효할 예정이다. 본 글에서는 IEC 표준의 개정안의 내용에 대하여 고찰을 하였다.

  • PDF

Development of a Techniques of the Performance Test for a Radiation Protection Devices and it's International Standards (방사선 방호용 계측기 성능평가 기술 개발 및 국제 표준)

  • Choi, Kil-Oung;Won, Sung-Ho;Kim, Jung-Ho;Hah, Suck-Ho;Yi, Chul-Young;Kim, Hyun-Moon;Lee, Min-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • International Standardization in all technical area is gaining its momentum as its impact and implication over global trade is directly linked. The worldwide competition to secure a dominant position in the standardization process is ever growing over the years. In 2005, the International Technical Committee on Nuclear Instrumentation, which is a subunit of International Electro-technical Commission (IEC), was held in Korea under the auspices of MOST (Ministry of Science and Technology). Korea has adopted its Rule and Regulation as the National Standard. As a part of a link to National Mid-and Long-term Atomic Energy R&D Program of MOST, the technical development of a performance test for the radiation monitors was carried out under mechanical environment and electromagnetic immunity conditions. The characteristics of the radiation fields were also evaluated under the conditions and introduced to a techniques of performance test for the radiation protection instrumentation adopted IEC61526 standards and it's results was analyzed. We would like to share the experience gained in these efforts, failure as well as success, and to discuss the problems encountered and serious consideration to be taken into account in the future endeavor.

자동차 전자파

  • 성현수;신승현;문진동;한종철
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.4
    • /
    • pp.83-93
    • /
    • 1994
  • 1886년 고트리브 다이믈러와 칼 벤즈가 가솔린 자동차를 개발한 이후 100여년이 지난 지금 자동차는 비약적으로 진보, 발전하여 현대 산업사회와 개인의 생활에 있어 산업운송수단과 이동수단으 로서 필요불가결하게 되어 밀접한 관계를 갖고 있다. 우리나라 자동차 공업의 역사는 자동차가 사회적, 경제적 효용에 따라 그 생산과 보유대수가 날이 갈수록 증가 일로에 있으며, 자동차의 생산대수는 전세 계에서 년간 약 50,606천대('94년)로서 중요한 국가 기간 산업으로 자리하고 있다. 한편 전기, 전자공업의 발전에 따른 자동차의 Car Electronics가 많이 채용되게 됨에 따라 현재의 자 동차에는 대부분이 전자제어 System으로 구성되어 있다. 최근에는 Micro Processor를 이용한 전자부품이 많이 사용되어 전자파에 대한 문제가 다양하게 발생 하고 있다. 예를 들면 미국 캘리포니아주에서 전자점화제어장치와 연료분사 장치를 설치한 구미의 자동 차가 주행중 28MHz, 28W의 아마추어 무선을 탑제한 자동차가 통과할 때 엔진이 고르지 못한 보고가 있 었고, 화학섬유로된 옷을 착용한 전자부품이 다른 부품에 영향을 주는 사례가 맣아지고 있다. 따라서 자동차에는 여러가지의 전장품, 전자기기를 탑재하기 때문에 자동차 자체에서 발생하는 것과 외부로 부터 받는 전자장해 EMI(Electromagnetic Interference), EMS(Electromagnetic Susceptibility) 가 문제로 되어 자동차 및 부품 maker에 의한 EMC(Electromagnetic Compatibility) 평가의 중요성이 고조되고 있다. 차제무전기, 차제무전기, Car-Radio는잡음방해를 많이 받기도 하지만, 잡음원이 되기 도 한다. 또한 Engine 제어, 차속제어, Brake 제어등에 이용되는 전자제품은 방해에 의한 오동작 또는 파괴가 발생하여 주행기능, 안전성에 문제가 야기되지 않도록 해야 한다. 이러한 전자기 환경은 모두 RF(Radio Frequence)와 자동차에서의 전자파 장해 문제의 원이 될 수 있다. 자동차 및 그 부품의 전자기 방해에 관한 규격화는 1987년부터 괄목할 만하게 진행되어 이에 따른 규제 움직임이 IEC(International Electrotechnical Commission: 국제전기기술위원회) 산하의 하부기 구인 CISPR(International Special Committeeon Radio Interference: 국제 무선 장해 특별위원회)가 전자기 방해파에 대한 측정법 통일안을 제안 하였고, ISO(International Standardization Organiza- tion: 국제표준화 기구) 가운데 TC 22/SC3가 자동차의 전장품에 대한 장해를 논의히고 있다. 특히, 자동차의 EMC에 관한 국가 규격은 국제 규격에서 저술한 바와 같이 특별히 규정된 것이 없고 VDE(Verband Deutscher Elektrotechniker: 서독전기기술 협회)와 SAE(Society of Automotive Engi- neers: 자동차 기술자 협회)에서 비교적 활발하고 Jaso(Japanese Automobile Standards Organization: 일본 자동차 표준협회)에서 많이 진행중에 있다. 본 고에서는 자동차의 전자제어에 따른 잡음 발생 요인과 전자파 간섭 관련 자동차 규격과 시험평가 방법에 대해 간단히 소개 하였다.

  • PDF

The effect of electromagnetic of the electrostatic discharge device with the high-voltage air discharge (고전압 기중방전을 갖는 정전 방전장치의 전자기 영향)

  • Kim, Myoung-Seok;Oh, Joon-Sick;Han, Gyu-Hwan;Park, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1482-1483
    • /
    • 2006
  • 고전압 방전시험 장치는 국제전기기술위원회 규격(IEC 61000-4-2)에서 규정하고 있는 콘덴서 방식을 사용하며, 매우 짧은 시간에 방전함으로서 펄스 형태의 방전전류가 통전된다. 이러한 정전기적인 방전에 의해 전자기기에 고장을 발생시키며 이를 검증하는 방법으로 정전기 내성시험법이 있다. 본 논문에서는 첫째로 방전장치가 발생하는 잡음 전계량을 측정하였고, 둘째로 방전장치를 시험시료에 근접하는 방법에 따른 시험시료에 미치는 영향을 실험을 통해 검증하였고, 셋째로 근접방법에 따른 정전유도 현상이 시험시료에 미치는 영향을 실험적으로 검증하였다. 이러한 세 가지 현상을 바탕으로 시험시료가 고전압 방전장치를 근접 방전하여 방전을 유발시켰을 때의 전자파의 영향에 내성을 갖고 있는지를 검증하는 새로운 시험방법을 제안하였다.

  • PDF

Development of Device Management and Safety Diagnosis Manual for Electrical Stimulating Swallowing-Assist Equipments (전기적 자극방식 삼킴 보조 치료기의 장비관리/안전진단 매뉴얼 개발)

  • Heo, S.Y.;Choi, B.G.;Rhee, G.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • In Republic of Korea, there are considerable vulnerability in electrical stimulating swallowing-assist equipments even though they are professional medical equipments and have high penetration rate with heavy frequency of use. Therefore, in this article, we developed Device Management and Safety Diagnosis Manual for Electrical Stimulating Swallowing-Assist Equipments system. For achieving this, we collected and analysed international standard data from international organizations like International Electrotechnical Commission(IEC). After literature reviews, we build maintenance worksheet and equipment procedure manual for electrical stimulating swallowing-assist equipments according to evidences we collected. These manual and protocol would be used as standard process and contribute to sustain accuracy, effectiveness of the devices, also decrease failure rate and assist to save medical documents.

  • PDF

Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

Light Pollution of Outdoor Lighting in Coastal Area - Focused on Busan City - (해안가 야간경관조명의 빛공해 평가 - 부산시를 중심으로 -)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.18-26
    • /
    • 2010
  • Outdoor lighting has become a necessary essential part of society for safety and comfortable space. However, inappropriate outdoor lighting leads to energy waste and poor landscape. Outdoor lighting is a very important social element, which enables us to conduct various activities at night in a safe, efficient and comfort way. River Thames in UK, Venice in Italy and Sydney in Australia is a good example of the coastal area. This paper aims to evaluate the light pollution of outdoor lighting in coastal area in Busan city. The Radiant Imaging ProMetric-1400 was used to measure the luminance of Gwangalli Beach, Marine City and Haeundae Beach. Compare to the CIE recommendation level the luminance of the all outdoor lighting were about 2~20 times higher. Outdoor lighting of the building facade luminance level and color should be particularly limited.

Calculation of the Electromagnetic Fields Distribution around the Human Body and Study of Transmission Loss Related with the Human Body Communication (인체 통신에 따른 인체 주변에서의 전기장 분포 계산 및 전송 손실 연구)

  • Ju, Young-Jun;Gimm, Youn-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.251-257
    • /
    • 2012
  • Human body communication means transmitting and receiving data through human body medium or through free space along with the human body skin. Electric field distribution around the human body between the transmitter and the receiver were calculated at five different frequencies with 5 MHz interval between 10 MHz and 30 MHz. Commercial electromagnetic simulation tool was used for the calculation of E-field distributions applying the Korean standard male model including 29 different kinds of human tissues. After calculating specific absorption rate(SAR) values on back of the hand, it was compared with International Commission on Non-Ionizing Radiation Protection(ICNIRP) human protection guideline. While conductivities(${\sigma}$) and relative permittivities(${\varepsilon}_r$) of the human tissues for each frequency were input as the analyzing parameters, electric field intensities near both hands were integrated along the integral line between the nearby electrodes for the calculation of the transmitting and receiving voltages whose ratio was defined as channel loss. The calculated channel losses were about ($75{\pm}1$) dB and showed nearly flat response all through the evaluated frequencies.