• 제목/요약/키워드: 국소의치

검색결과 299건 처리시간 0.026초

골내 임프란트를 이용한 고정성 국소의치 하에서 변위 및 응력에 관한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF STRESSES AND DEFLECTIONS INDUCED BY FIXED PARTIAL DENTURE USING ENDOSTEAL IMPLANT)

  • 최수호;정재헌
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.233-248
    • /
    • 1991
  • The purpose of this study was to qunatatively analyze the stress patterns induced in the abutment, superstructure, supporting bone and to determine the deflection of abutment and superstructure by appling occlusal force to natural teeth supported fixed prostheses and implant-supported fixed prostheses. The analysis has been conducted by using the two dimensional finite element method. The implant and natural tooth-supported bridge has a first molar pontic supported by mandibular second bicuspid and implant posterior retainer, which were rigidly(Model A) or flexible(Model B). The natural teeth-supported bridge has a first molar pontic supported by mandibular second bicuspid and second molar, which were rigidly splinted together(Model C). 63.5kg(Load P1) of localized load on central fossa of first molar pontic and 24kg(Load P2) of distributed load on each occlusal surface were applied respectively. 1. The coronal portion of premolar pontic and posterior abutment in fixed partial denture deflected inferiorly in order of Model B, Model C and Model A under Load P1 and Load P2. 2. Mesial displacement of the coronal portion of premolar showed in Model A, Model B and Model C under Load P1, but mesial displacement of that in Model B and distal displacement of that in Model A and Model C showed under Load P2. 3. Mesial displacement of the coronal portion of the pontic and distal displacement of the coronal portion of posterior abutment showed in Model A, Model B and Model C under Load P1 and Load P2. Displacement in the case of Model B was greater than that of Model A and Model C. 4. In the case Model A under Load P1 and Load P2, high stress apically was concentrated in the mesiocervical portion of the posterior abutment than in the disto-cervical portion of the premolar. 5. In the case of Model B under Load P1 and Load P2 high stress was concentrated in the case of the premolar than in that of posterior abutment and high stress especially was concentrated in the connected portion of pontic and posterior abutment. 6. In the case of Model C under Load P1 and Load P2, high stress was concentrated in the distal area of the cornal portion of premolar and the mesial area of the coronal portion of posterior abutment, and stress pattern was anteroposterially symmetric around the pontic. 7. Load P1 and Load P2 compared, stress magnitude was different but stress pattern was similar in Model A, Model B and Model C. 8. Under Load P1 and P2, stress magnitude in the mesial distal portion and the portion of root apex of the posterior abutment was in order of Model B, Model A and Model C.

  • PDF

유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구 (Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures)

  • 임순호
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

만성 치주염 환자에서 소수 잔존치와 임플란트를 이용한 전악 수복: 증례 보고 (Full mouth rehabilitation with a few remaining teeth and implants for a patient with chronic periodontitis: a case report)

  • 신은정;방몽숙;양홍서;박상원;임현필;윤귀덕
    • 구강회복응용과학지
    • /
    • 제31권3호
    • /
    • pp.253-261
    • /
    • 2015
  • 만성 치주염 환자 치료시 잔존치 발치 여부를 결정할 때 신중을 기해야 한다. 고정성 또는 가철성 국소의치 치료시 치주조건이 불량한 치아를 지대치로 사용하면 과부하로 조기실패가 우려되어 발치를 고려하지만, 임플란트 고정성 보철물의 경우 잔존치로 전달되는 기능하중을 감소시킬 수 있기 때문에 잔존치를 유지시키는 경우가 많다. 잔존치를 이용한 전악수복시 proprioceptive response를 보존할 수 있어 악간관계와 교합평면 결정시 도움이 될 뿐 아니라 환자의 보철물에 대한 적응이 쉽다. 본 증례의 환자는 치주질환에 의해 다수치 상실 및 대합치의 정출을 보였다. 동요도가 심해 예후가 좋지 않은 치아를 발거하고 소수 잔존치와 임플란트로 전악수복하여 적절한 기능적, 심미적 결과를 얻었다.

전반적인 치아의 마모로 인한 수직고경 감소와 과피개교합을 갖는 환자의 전악 수복 증례 (Full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to worn dentition)

  • 남기훈;박필규;김희경;강정경
    • 대한치과보철학회지
    • /
    • 제54권1호
    • /
    • pp.65-71
    • /
    • 2016
  • 치아 교합면의 점진적인 마모는 나이가 들면서 진행되는 정상적인 과정이다. 그러나 과도한 마모는 병적인 치수 상태, 교합 부조화, 기능 장애 및 심미적인 문제를 가져온다. 치아 수복을 위한 공간 확보, 심미성 증진, 또는 교합관계를 수정하기 위해서는 수직고경 변경을 고려하여야 하는데 환자의 심미적 요구와 술자의 기능적 목표를 최소침습적으로 달성하는 것을 충족시키는 범위 내에서 수직고경을 결정하고 새로운 수직고경에 대한 적응 평가를 함께 이루어야 한다. 그리고 과피개 교합 문제는 단순히 피개 교합의 정도에 국한된 문제라기 보다는 전후방적인 교합 문제를 복합적으로 지니고 있는 경우가 많다. 이러한 고려사항을 생각해 보았을 때 근본적인 문제 해결을 위해서는 악골 및 치아의 전후방적인 관계 개선과 더불어 결손부의 적절한 수복이 뒤따라야 한다. 본 증례는 67세 남자 환자로 다수 치아 마모와 구치부 상실된 환자로 수직고경의 증가를 동반하여 하악 무치악 부위는 가철성 국소의치, 상하악 유치악 부위는 고정성 보철물로 수복을 하였으며, 이에 기능적, 심미적으로 만족스러운 결과를 얻었기에 증례를 보고하고자 한다.

임플란트를 이용한 국소의치 수복 (Implants in conjunction with removable partial denture)

  • 김성균;유수연;박인필;이주희
    • 대한치과의사협회지
    • /
    • 제49권2호
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

CAD/CAM을 이용한 구치부 전부도재 고정성 국소의치 지르코니아 코어의 연결부 설계에 따른 파절강도 (FRACTURE STRENGTH BETWEEN DIFFERENT CONNECTOR DESIGNS OF ZIRCONIA CORE FOR POSTERIOR FIXED PARTIAL DENTURES MANUFACTURED WITH CAD/CAM SYSTEM)

  • 서준용;박인임;이근우
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.29-39
    • /
    • 2006
  • Statements of problem: Zirconia core is used for posterior fixed partial dentures because it's good mechanical properties. Stress is concentrated on connectors in fixed partial dentures, so the proper design of connector areas is needed for adequate mechanical long-term properties of any prosthesis. The area of connector is critical, but tooth size and surrounding soft tissue limit the connector design. Purpose: The purpose of this study is to compare fracture strengths between different connector designs of zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system and determining the optimal connector design satisfying strength and hygiene. Material and method: The following four groups of 40 posterior fixed partial denture specimens(each group 10) were fabricated as followed; group 1 vertical height of connector is 3mm (control group, all groups have the same condition); group 2, lingual vertical 1mm reinforcement on connector; group 3, lingual vertical 2mm reinforcing on connector and group 4, lingual vertical 3mm reinforcing on connector. Specimens were subjected to compressive loading on the central fossa of pontic by instron. SEM was used to identify the initial crack and characterize the fracture mode. Results: The results were as follows: 1. The mean fracture load of the non-lingual reinforcing group was 1212N and the lingual vertical 1mm reinforcing group was 1510N, the lingual vertical 2mm reinforcing group was 1882N, the lingual vertical 3mm reinforcing group was 1980N. 2. The reinforcing groups were statistically significant compared to non-reinforcing groups(P<0.001). 3. There were 2, 3mm reinforcing groups that were statistically significant compared to 1mm reinforcing groups(P<0.001), and the 3mm reinforcing group was not statistically significant compared to 2mm reinforcing groups(P>0.05) 4. Fractures were initiated in gingival embrasures of connectors and processed to the loading site. Conclusion: In this study, lingual reinforcement of connector for improved strength of zirconia based fixed partial denture is nessasary. And long-term study for clinical application is required

하악 편측 유리단 국소의치의 직접유지장치 형태에 따른 3차원적 광탄성 응력분석 연구 (THREE-DIMENSIONAL PHOTOELATIC STRESS ANALYSIS OF CLASP RETAINERS INFLUENCED BY VARIOUS DESIGNS ON UNILATERAL FREE-END REMOVABLE PARTIAL DENTURES)

  • 김병무;유광희
    • 대한치과보철학회지
    • /
    • 제32권4호
    • /
    • pp.526-552
    • /
    • 1994
  • The extent and direction of movement of removable partial dentures during function are influenced by the nature of the supporting structures and and the design of the prosthesis. Since forces are transmitted to the abutment teeth through occlusal rests, guide planes and direct retainers during functional movements, proper design based on the avaialble research data will maintain the health of abutment teeth and their supporting structures. The purpose of this in vitro study is evaluating stress distribution clinically around the abutment teeth prepared following 4-type clasping systems for unilateral free-end removable partial dentures. Three-Dimensional Photoelastic Stress Analysis method was used because it shows a visual display of stresses of the simulated abutment teeth and residual ridges and reveals stress concentration that can be read at any given points in terms of direction and magnitude. For this study, the author fabricated 4 mandibular photoelastic epoxy models missing left 1st and End molar. Epoxy models were duplicated and 4 unilateral removable partial dentures were construe- ted in accordance with 4-type direct retainers. Unilateral free-end removable partial dentures were positioned on their own models. 6kg force was loaded on the every removable partial dentures of the epoxy model on the central fossa of mandibular left 1st molar vertically by the loading device. After the stress was frozen in a stress freezing furnace, 6 specimens of 6-mm thickness were made from every epoxy model and examined with the circular polariscope. The results were as follows : 1. Generally I-bar clasp revealed the most favorable stress distribution around the abutment teeth. 2. At the end portion of the free-end ridge, Back action clasp showed the highest stress concentration at the bucco-lingual and top portions of the residual alveolar ridge. 3. At the distal area of the abutment teeth, Akers clasp and Roach clasp showed higher stress concentration bucco-lingually and apically than the others. 4. To the abutment tooth, I-bar clasp showed the least stress distribution bucco-lingually but the others showed irregular stress distribution. 5. At the mesial area of the abutment teeth, the order of effective stress distribution was I-bar clasp, Back-action clasp, Akers clasp and Roach clasp. There was big difference of stress distribution between them. 6. At the right 2nd premolar and 1st molar, the stress concentration of Akers clasp was a little high but that of I-bar clasp was low.

  • PDF

상악골 절제술을 받은 부분 무치악 환자에서 생역학을 고려해 제작한 구개 폐색장치를 이용한 보철 수복 증례 (Prosthetic rehabilitation by obturator considering the biomechanics in partially edentulous patient after maxillectomy)

  • 이강신;박주미;안승근;서재민;박연희;이정진
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.281-293
    • /
    • 2021
  • 상악골 절제술을 받은 환자는 구개부의 결손으로 인해 연하, 저작, 발음 기능이 심각하게 손상되는데, 식사 시 비강과 코를 통한 누출이 있게 되고, 치아 및 치조제의 소실로 저작이 어려워지며, 구강과 비강이 분리되지 않아 과비음이 발생하는 등 삶의 질이 현저히 저하된다. 결손부를 보철적으로 재건하기 위해서는 폐색장치의 무게를 최대한 줄여 중력에 의한 탈락을 최소화하고, 폐색장치의 bulb를 결손부 내로 적절히 연장시켜 부가적인 유지, 안정을 얻도록 해야 한다. 본 증례는 종양의 재발로 인해 추가적인 상악골 절제를 받은 부분 무치악 환자에서 가철성 국소의치의 기본적인 설계 원칙을 적용하여 금속 구조물을 디자인하고, 기능 인상을 통해 유지, 안정, 지지를 향상시킨 폐색장치를 제작하였다. 환자는 개선된 안모 및 저작, 연하, 발음 기능 향상에 만족하였고, 경과관찰 기간 동안 안정적인 교합 및 구강위생관리를 보여 이를 보고하는 바이다.

치아 상실과 심한 마모를 보이는 골다공증 환자에서의 완전구강 회복 증례 (Full mouth rehabilitation in osteoporosis patient with loss of teeth and excessive wear)

  • 김현탁;김명주;임영준;권호범
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.63-70
    • /
    • 2022
  • 구치부 치아 상실을 동반한 치아 마모는 불규칙한 교합평면, 과도한 전치부 마모와 같은 특징적인 양상을 보인다. 적절한 구치부 지지를 부여하고 조화로운 전방유도와 교합평면을 설정하는 치료 방법이 추천된다. 본 증례 보고의 환자는 치아의 병적인 마모가 관찰되고 하악 구치부 치아가 상실되었다. 또한, 골다공증 병력과 Ibandronate 주사 치료와 관련된 골괴사증의 위험성을 인지하고 수술적 치료를 거부하였다. 본 증례에서는 마모된 잔존치를 수복 공간 확보를 위해 수직 고경 거상을 동반한 완전구강회복술로 수복하고, 하악 무치악부는 양측성 후방연장 국소의치로 수복하였다. 면밀한 진단을 통해 수복 계획을 수립하고, 이를 바탕으로 지대치 형성 후 임시 보철물 상태로 적응 기간을 거쳐 최종 보철물 제작하였다. 심미적, 기능적으로 만족할 만한 결과를 얻을 수 있었고, 구강 위생관리 및 교합 안정성을 확인하기 위해 정기적으로 내원하도록 하였다.

내부연결 임플란트의 보철 수복 후 성공률에 미치는 위험요소에 관한 10년간의 후향적 연구 (A 10-year retrospective study on the risk factors affecting the success rate of internal connection implants after prosthetic restoration)

  • 이서인;김민정
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.113-124
    • /
    • 2023
  • 목적: 본 연구의 목적은 임플란트 보철물의 종류 및 특성과 생존율 분석을 통해 성공률을 높이는데 도움이 되는 데에 있다. 대상 및 방법: 원광대학교 치과대학 산본치과병원에서 2011~2020년에 식립한 임플란트 중 한 명의 보철전문의에 의해 수복된 사례에 대하여 그 특성과 실패에 대한 상관관계 등을 조사하였다. 실패의 원인은 골유착 실패, 임플란트주위염, 고정체 파절, 지대주 파절, 나사 파절, 나사 풀림, 보철물 파절, 보철물 유지력 상실 등으로 분류했다. 보철방식, 캔틸레버 여부, 식립 위치 등과 임플란트 실패와의 연관성을 분석했다. 결과 분석은 SPSS ver 25.0 (IBM, Chicago, IL, USA)을 이용하여 Chi-square test, Kaplan-Meier 생존분석 등을 통하여 도출했다. 결과: 총 2587개의 임플란트가 식립되었으며, 그 중 1141개의 임플란트가 단일관(Single Crown)으로, 1446개의 임플란트가 고정성 국소의치(Fixed Partial Denture)로 수복되었고 누적생존율은 88.1%이었다. SC의 성공률은 86.2% (984개), FPD의 성공률은 89.6% (1295개)로 통계적으로 유의한 차이를 보였으며 그 중 유의한 차이가 있었던 요인은 지대주 파절, 나사 파절, 나사 풀림 등이었다 (P < .05). 결론: 10년간의 추적조사 결과 생물학적인 요인보다는 생역학적인 요인으로 인한 실패가 더 많이 발생했고 임플란트의 성공률은 보철방식 별로 상이했으며 영향을 미치는 요인도 상이했다. 추후 임플란트의 성공에 관한 추가적인 연구가 더 필요할 것이다.