  • When restoration for partially edentulous patients, abutments are not always in favorable positions for making removable partial dentures. Because of these situations, patients are sometimes unsatisfied with the stability and support of their removable partial prostheses. In this regard, removable partial denture using a few implant surveyed crown prostheses can be a good alternative. It can be expected to increase stability and support of removable partial dentures by strategically placing a small number of implants and restoring with implant-supported surveyed crowns. In these cases, the patients who had unilateral residual teeth on mandible were treated with two implant surveyed crowns in the tactical place to have bilateral distribution. After definitive removable partial prosthesis, the patients showed satisfaction with the masticatory function and comfort of using removable dentures.

Diagnosis and treatment planning for removable partial denture: diagnostic cast analysis and abutment teeth selection (가철성 국소의치의 진단 및 치료계획: 진단모형 분석과 지대치 선정)

  • Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.45-52
    • /
    • 2014
  • Diagnosis and treatment planning is initial step to fabricate removable partial denture, and one of most important factor influencing the prognosis. Partial edentulous patients have various condition of remaining teeth and oral mucosa. Therefore, for the proper diagnosis and treatment planning for each patient, getting many informations from patients during initial examination and fabricating accurate diagnostic cast are required. Especially, because the use of various diagnostic tools and surveying of diagnostic cast will be a guide for the abutment teeth selection, oral preparation and design of partial denture, dentist should understand and be able to apply this procedure during diagnosis.

Initial Placement of Removable Partial Dentures (가철성 국소의치의 장착)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.299-307
    • /
    • 2013
  • The overall objective of fitting removable partial dentures at initial placement is to ensure that the patient is given the best possible start with the new prostheses. This may be achieved by checking that: (1) final inspection of the prosthesis, (2) seating of the RPD framework, (3) evaluation of denture base adaptation, (4) assessment of denture base peripheral extensions, (5) occlusal adjustment, (6) remounting the prosthesis, and (7) instructions to the patient.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

The Fabrication of Accurate Removable Partial Denture by Analyzing the Failed Cases (실패 증례 분석을 통한 국소의치 제작 시 주의사항)

  • Lee, Ji-Young;Lee, Kyoung-Lok;Heo, Yu-Ri;Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.280-289
    • /
    • 2013
  • Removable partial denture for oral function recovery of partial edentulous patients is a complicated treatment because the dentist should consider both hard tissue and soft tissue. Removable partial denture produced without consideration of precise design for each component and rotation of denture may cause fracture, deformation or loss of abutment teeth. In case of failure to achieve a proper denture, the reason of failure should be analyzed and the result must be applied to later RPD cases. Finding the solutions through the failed denture cases will help patients use their dentures more comfortably and keep their sound residual teeth and tissue longer.

Fabricating retrofit crowns to an existing removable partial denture by CAD-CAM: a case report (CAD-CAM을 이용한 RPD 지대치의 retrofit crown 제작 증례)

  • Hyuksoon Lee;Seong-A Kim;Joo-Hyuk Bang;Sung Yong Kim;Hee-Won Jang;Keun-Woo Lee;Yong-Sang Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.140-145
    • /
    • 2024
  • Removable partial denture wearers are exposed to the risks that remaining teeth get damaged by caries, attritions, erosion, and fracture. In the case of damaged abutment tooth which should fit to Removable partial denture (RPD), the fabrication of surveyed crown is followed by the making of RPD. However, making new denture takes a long time, and needs several processes and costs. Also, patients should get used to new denture. If other abutment teeth and edentulous ridges provide the existing denture with support, retention, and stability, use of existing denture is considered clinically acceptable. In this situation, fabricating retrofit crowns to an existing removable partial denture makes patient use existing denture, cuts costs, and reduces discomfort. In this case, severely worn teeth were restored using monolithic zirconia crown which fit to an existing removable partial denture by CAD-CAM. Moreover, support, retention, and stability of the denture were improved, and both doctor and patient were satisfied with the result.

A clinical case of hybrid telescopic double crown using friction pin with an isolated few remaining teeth (고립된 소수 잔존치 환자에서 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관 국소의치의 임상증례)

  • Sohn, Sang-Hyuk;Cho, Jin-Hyun;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.80-86
    • /
    • 2016
  • A few authors have reported good clinical results using double crown removable partial denture (RPD) with a few remaining teeth. Hybrid telescopic double crown is a good indication for a patient with poor periodontal condition and/or few remaining teeth after extraction, especially located in cross-arch position. In this case, there was a poor periodontal condition with teeth mobility. Several teeth with poor prognosis were extracted. Remaining anterior teeth was restored with fixed prostheses and edentulism was restored with Kennedy class I removable partial denture in maxilla. In mandible, it was hard to restore with clasp removable partial prostheses because of bilaterally isolated remaining teeth so that hybrid double crown removable partial denture with friction pin was suitable for this case. The objective of this report is to discuss the characteristics and the utility of hybrid double crown prostheses using a few remaining teeth in mandible.

The fabrication of abutment crowns for existing removable partial denture using CAD/CAM: A clinical report (CAD/CAM을 이용하여 기존 국소의치에 맞는 지대치 보철물 제작 증례)

  • Chae, Min-Jeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.490-494
    • /
    • 2019
  • Abutment teeth supporting removable partial denture could be faced a number of problems including development of dental caries. If the existing removable partial denture is in clinically acceptable state and the patient does not want to replace the existing removable partial denture, then a new prosthesis for abutment teeth need to be made. The procedure of fabricating a new prosthesis of abutment teeth for existing removable partial denture is complicate and technically challenging. To fabricate the abutment crown, the original cast of patient obtained before any complication to the abutment teeth is required. The original cast should also contain teeth other than the abutment teeth as a reference point. Once the cast is prepared, CAD/CAM could be used to produce retrofitting prosthesis effortlessly and efficiently. This clinical report presents fabricating a crown to fit existing removable partial denture using CAD/CAM for a patient with post and core failure and dislodged prosthesis. The prosthesis had high stability with minimum adjustment yielding satisfying result.

Valplast$^{(R)}$ flexible removable partial denture for a patient with medically compromised conditions : a clinical report (전신적 질환자 및 예후가 불량한 환자에서 Valplast$^{(R)}$ 탄성 국소의치의 적용)

  • Choi, Bohm;Kim, Seong-Hun;Lee, Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.295-300
    • /
    • 2009
  • Statement of problem: As the number of elders is growing with the advancement of medicine, partially or fully edentulous patients have increased. Medically compromised conditions are common in the older population so that it should be taken into account in prosthetic treatment planning as well as their economic conditions. In the older patients, removable prosthesis has been preferred to implant prosthesis. However, cast metal based removable partial dentures also has several limitations. Purpose: In this report, we present several cases of Valplast$^{(R)}$ flexible denture which were fabricated in patients who had medically compromised conditions or whose remaining teeth showed a relatively poor prognosis. Results & Conclusion: This article describes an alternative treatment for a partially edentulous patient with mouth opening limitation, after cancer surgery, compromised general condition and questionable remaining teeth. In these patients, Valplast$^{(R)}$ flexible denture was used because of its unique characteristics and the results were all satisfactory. Patients had 1-2 check-up and there were no postoperative pain or fracture of denture up to now.

Postinsertion Adjustment Procedures of Removable Partial Dentures (가철성 국소의치의 조정)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.384-390
    • /
    • 2013
  • Postinsertion problems tend to be minimized when a sequential insertion procedure is followed. However, problems may occur as the result of one or any combination of comfort, function, esthetics, and phonetic difficulties. Following the insertion of a partial denture, an appointment for review in approximately 7 days should be made for the patient. At the review visit, the patient should be questioned concerning any problems that have been experienced when wearing the denture. A thorough examination should then be carried out of the oral tissues and the denture, in the course of which signs of tissue damage may be observed. A diagnosis is then made of the cause of all the problems revealed in the history and examination procedures. Appropriate treatment should then be applied to resolve these problems.