• Title/Summary/Keyword: 국소열전달계수

Search Result 45, Processing Time 0.035 seconds

A Study on the Mass Transfer from a Square Cylinder Using Naphthalene Sublimation Technique (나프탈렌승화법을 이용한 사각관 주위에서의 물질전달에 관한 연구)

  • 유성연
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1300-1310
    • /
    • 1990
  • Naphthalene sublimation technique is employed to investigate the mass transfer processes from a square cylinder at various Reynolds numbers and various angles of attack. Distribution of the local mass transfer coefficients on each face of the cylinder changes dramatically with the angle of attack. Such variation of local mass transfer rates closely connected with the complex flow phenomena such as stagnation, acceleration, separation, reattachment and vortex shedding. The average Sherwood number has a minimum value at 12.deg.-13.deg., and a maximum value at a=20.deg.-25.deg. A comparison of present mass transfer measurement with other heat transfer measurements, using the heat/mass transfer analogy, shows good agreement in average transfer rates, same trend but notable differences in local values. Therefore, naphthalene sublimation technique can be adopted to explore heat transfer processes in the complex flow situations, which is considered to be hardly possible with the conventional heat transfer measurements.

Heat Transfer Characteristics of Plate-fin Heat Exchanger Using LNG FPSO Liquefaction Process (LNG FPSO 액화공정에 적용되는 플레이트 핀 열교환기의 열전달 특성)

  • Yoo, Sun-Il;Kim, Hyun-Woo;Jung, Young-Kwon;Yoon, Jung-In;Park, Seung-Ha;Kim, Chang-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.798-805
    • /
    • 2010
  • There are no domestic researches of plate fin heat exchanger in the field of cryogenic such as LNG FPSO liquefaction plant. In this study, condensing heat transfer characteristics of nitrogen according to three kinds of fin type in the plate fin heat exchanger were analyzed through simulation and experiment to secure independent technologies. In the simulation, nitrogen was condensed at 69bar and $-140^{\circ}C$ in serrated and wavy fin of plate-fin heat exchanger. The serrated fin shows the highest value of local heat transfer coefficient, followed by wavy and plain fin. The experimental results were shown errors less than 12% comparing with the simulation results.

핵연료 봉다발에서의 국소열전달 특성 해석

  • 이중섭;정장환;오광석;김선철;유성연
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.391-396
    • /
    • 1996
  • 내부부수로, 벽면부수로, 모서리부수로를 포함하는 가압경수로형 원자로의 핵연료집합체를 모의하는 3$\times$3 봉다발을 모델로 수치해석을 통해 봉다발 주변의 유동특성을 알아보고 각 봉에서의 원주방향 위치에 따른 국소열전달 특성에 관해 고찰하였다. 봉다발에서 열전달계수의 분포는 벽면영향으로 인한 각 부수로에서의 유속분포와 밀접한 관계가 있으며 내부부수로에 인접한 봉에서 가장 높았고, 그 다음이 벽면부수로, 모서리부수로에 인접한 봉에서는 가장 작게 나타났다. 현재 핵연료의 열수력 설계시에 적용하고 있는 부수고 내의 모든 열수력학적 변수가 일정하다고 가정하는 부수로 해석방법은 봉다발내의 실제 열전달 현상과는 상당한 차이가 있음을 보여주었다.

  • PDF

The effect of wall heat conduction on local convection heat transfer from a cylinder in cross flow of air (원형 실린더 주위의 공기로 국소 대류 열전달에 대한 열전도의 영향)

  • 이승홍;이억수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.440-448
    • /
    • 1998
  • This paper considers the influence of circumferential wall heat conduction for the case of forced convection around a circular cylinder in cross flow of air. Keeping uniform heat generation from the inner surface of the cylinder in radial direction, heat is transferred by wall conduction in the circumferential direction due to the asymmetric nature of the temperature distribution of the cylinder and by convection around the perimeter of the cylinder. The wall conduction depends on conductivity of the cylinder and size of the cylinder radius and thickness and affects the local convective heat transfer rate significantly for geometrically similar surfaces and flow conditions. A nondimensional conjugation parameter K. (=k$_t$R/k$_w$b) has been used to characterize the effect of the circumferntial wall heat conduction. The small values of conjugation parameter K are found to be associated with large effect of wall conduction on the local convective heat transfer rate.

  • PDF

Numerical Study of Laminar Flow and Heat Transfer in Curved Pipe Flow (곡관에서의 층류 유동 및 열전달에 관한 수치해석 연구)

  • Kang, Changwoo;Yang, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.941-951
    • /
    • 2013
  • A three dimensional numerical simulation of laminar flow and heat transfer in fully developed curved pipe flow has been performed to study the effects of Dean number and pipe curvature on the flow and temperature fields under the thermal boundary condition of axially uniform wall heat flux. The Reynolds number under consideration ranges from 100 to 4000, and the Prandtl number is 0.71. The curvature ratios are 0.01, 0.025, 0.05 and 0.1. The axial velocity and temperature profiles and the local Nusselt number obtained from the present study are in good agreement with the previous numerical and experimental results currently available. To show the effects of pipe curvature on the flow and heat transfer, the resistance coefficients and heat transfer coefficients are computed and compared with the results of the previous theoretical and experimental studies. The averaged Nusselt number is correlated with Dean and Prandtl numbers. Furthermore, the critical Reynolds number for transition to turbulent flow is observed to depend upon the curvature ratio.

Flow and Heat Transfer Characteristics on Oblique Impingement Surface by Single Axisymmetric Jet (단일 축대칭제트에 의한 경사충돌면에서 유동 및 열전달 특성)

  • 이창호;황상동;조형희;정학재
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.34-40
    • /
    • 1999
  • An experimental study has been conducted to determine the effects of inclined impinging jet on the local heat transfer coefficients. A single jet with nozzle diameter of 24.6 mm was tested for Reynolds numbers from 10,000 to 70,000 and nozzle-to-plate spacings of 2~6 jet diameters. The angle of inclination of the impingement surface relative to the horizontal surface was varied from $0^{\cire}$ (normal impingement) to $60^{\cire}$. The results indicate that the point of maximum heat transfer is moved up from the geometrical stagnation point of inclined surface by Coanda effect. The local heat transfer coefficients on the minor jet region decrease more rapidly than on the major jet region, thus creating an imbalance in the cooling capabilities on the two sides.

  • PDF

Measurement of Local Heat Transfer Coefficients and Numerical Analysis in the Flow Passage of Disc Brake with Spirally Grooved Surfaces (나선형 홈을 가진 브레이크 유로 내에서의 국소 열전달 측정 및 열 유동 해석)

  • Lee, D.H.;Park, S.B.;Lim, C.Y.;Kim, H.S.;Lee, K.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.104-111
    • /
    • 2006
  • A ventilated disc brake having spirally fluted surface has been proposed to improve the thermal judder by way of heat transfer enhancement. The local heat transfer coefficients were measured in the flow passage of disc brake. These measured local heat transfer data were utilized to do the finite element numerical analysis which predicts the maximum temperatures on the disc brake. The results show that the maximum temperatures on the disc surface with spirally fluted surface are approximately 26.6% lower than those without them.

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

Wall Heat Conduction and Convection Heat Transfer from a Cylinder in Cross Flow (원형 실린더 주위의 전도-대류 열전달)

  • 이상봉;이억수;김시영
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.1-8
    • /
    • 2001
  • With uniform heat generation within the wall of the cylinder placed in a cross flow, heat flows by conduction in the circumferential direction due to the asymmetric nature of the fluid flow around the perimeter of the cylinder. The circumferential heat flow affects the wall temperature distribution to such an extent that in some cases significantly different results may be obtained for geometrically similar surfaces. In the present investigation, the effects of circumferential wall heat conduction on local convective heat transfer is investigated for the case of forced convection around horizontal cylinder in cross flow of air. Two-dimensional temperature distribution $T_w$/(${\gamma}$,${\theta}$) is presented through the numerical analysis. The one-dimensional and two-dimensional solutions are in good agreement with experimental results of local heat transfer coefficients.

  • PDF

Heat Transfer Enhancement of Water Spray Cooling by the Surface Roughness Effect (표면거칠기 효과에 따른 스프레이 냉각의 열전달 향상 연구)

  • Lee, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.203-212
    • /
    • 2010
  • Water spray cooling has been widely used in a variety of industrial applications. The present study concentrated on quantitative measurements of the heat flux and heat transfer coefficient by water spray as it impinges on the rough surface of a hot steel plate at $900^{\circ}C$. A novel experimental technique was developed for a hightemperature heat flux gauge with a test block, cartridge heaters, and thermocouples that was used to measure the surface heat flux information on the hot steel plate for local heat flux measurements. The roles of the surface roughness on heat transfer are presented in this paper for well-characterized four rough surfaces with average rms roughness heights of $40-80{\mu}M$. The results show that the local heat transfer for rough surfaces is higher than that for a smooth surface. Heat transfer can be significantly increased by the presence of surface roughness elements, which can disrupt the thin thermal boundary layer. In addition, the heat transfer enhancement mechanism on a rough surface can be investigated by a different boiling regime.