Abstract
With uniform heat generation within the wall of the cylinder placed in a cross flow, heat flows by conduction in the circumferential direction due to the asymmetric nature of the fluid flow around the perimeter of the cylinder. The circumferential heat flow affects the wall temperature distribution to such an extent that in some cases significantly different results may be obtained for geometrically similar surfaces. In the present investigation, the effects of circumferential wall heat conduction on local convective heat transfer is investigated for the case of forced convection around horizontal cylinder in cross flow of air. Two-dimensional temperature distribution $T_w$/(${\gamma}$,${\theta}$) is presented through the numerical analysis. The one-dimensional and two-dimensional solutions are in good agreement with experimental results of local heat transfer coefficients.