A Study on the Effective Smoke Control Method of Large Volume Space Comparted by Smoke Reservoir Screen (제연경계벽으로 구획된 대형공간의 효과적인 제연방안에 관한 연구)

  • Kim, Tae-Hoon;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.34-41
    • /
    • 2011
  • This research examines problem that can happen in partial smoke control method among contiguity area smoke control system through engineering examination and CFD. And the ultimate purpose of this is to secure safety of a person inhabiting at fire department by presenting improvement plan. Now a days, in large space-area such as department store or mega-mall in which mainly applies "Partial Smoke Control Method", air is suppled from adjacent area and smoke is exhausted in fire room. For various reason, however, it is confirmed through simulation that if air is suppled in one direction, this can cause a fatal result to people of fire area because of the difficulty in securing the evacuation time. As an improvement plan, air is supplied at the same time in surroundings to fire department.

Study on Companion Dog Practice and Management System on Animal Hospital in Seoul City (서울시내 동물병원의 애완견 진료와 관리시스템에 관한 연구)

  • Kang, Dong-Joon;Chung, Byung-Hyun;Heo, Jung;Kang, Chung-Boo
    • Journal of agriculture & life science
    • /
    • v.43 no.2
    • /
    • pp.39-46
    • /
    • 2009
  • Ten animal hospitals in Seoul were selected, and of which 41,305 practice in total for recent 1 year were analyzed based on international classification of disease(ICD) of WHO. Of the entire practice, prophylaxis cases accounted for 42.2%. Of the 9,376 cases of internal diseases, digestive system diseases accounted for 4,957 cases(52.9%), respiratory system diseases 1,776 cases(18.9%), circulatory system diseases 1,239 cases(13.2%), and neoplasms diseases 413 cases(4.4%), respectively. In the estate investment expenses, to be specific, rental guarantee deposit accounted for about 50% of the entire estate cost, foregift(48%), and monthly rent(2%). Dividing the income of animal hospitals into medical service, articles selling, and pet-dog beauty, medical service accounted for 71.6% of the entire sales, selling of articles 16.7%, and pet-dog beauty 11.6%. Publicity work for the animal hospital was done mostly through web sites on internet(47%), then through local advertising papers(23.5%), and through bulletins and telemarketing(11.8%). Manpower of the animal hospitals in this study was mostly composed of veterinarians(45.5%) up to about half of the entire staffs, while there was no veterinary technician who had specialized education in that area.

A Study on the Architectural Planning of Ambulatory Care Unit of Dental Hospital (치과병원의 외래진료 단위공간에 관한 건축계획적 연구)

  • Lee, Hewi-Jin;Lee, Teuk-Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.2 no.3
    • /
    • pp.21-33
    • /
    • 1996
  • This study aims to decide optimized size of a dental care unit. The efficient treatment room makes its user so comfortable that treatment can be easier and faster. Therefore, an operating room is the most important part in the dental hospital. This study focused on the outpatient care unit of dental hospital. The hospital for the case study is selected recently rebuilt dental university hospital. This study is to survey the behavior of all user in the sector and treatment unit. As the result, optimized plan type and size for each cases are proposed.

  • PDF

An Experimental Study on the Fire Growth Characteristics of Solid Combustible Materials (고체 가연물의 화재성장 특성에 관한 실험적 연구)

  • Kim, Sung-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.112-115
    • /
    • 2011
  • 본 연구는 고체가연물의 초기 점화 및 화재성장과정에서의 발열량을 대형화재발열량계(large scale fire calorimeter)를 이용하여 정량적으로 측정하고 화재발생 초기에 화재성장특성 파악하고자 한다. 실험에 적용된 고체가연물 화재는 단일/이중 목재화재, 폴리프로필렌 소재의 쿠션화재, 목재 및 폴리프로필렌 소재의 카페트 화재이며 화재발달 단계에서의 화재성장특성을 시간 제곱 화재성장 시나리오와 비교분석하고 고체 기본가연물의 화재성장과정을 이해한다. 구획조건이 화재발열량에 미치는 영향을 파악하기 위하여 자유연소상태와 ISO-9705 화재실 내부에서 화재실험이 수행되었으며 화재성장특성과 최대발열량등을 비교하였다. 본 연구는 설계화재와 화재시나리오를 설정하는데 있어서 고체가연물의 발열량 데이터 및 화재성장에 대한 정보를 제공하고 공간조건에 따른 발열량 측정데이터의 신뢰성 분석을 위한 기초연구로 활용될 수 있다.

  • PDF

Mixture Fraction Analysis on the combustion gases in the Under-Ventilated Compartment Fires (환기부족 구획화재에서 연소가스의 혼합분율 분석)

  • Ko, Gwon-Hyun;Kim, Sung-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.423-430
    • /
    • 2009
  • 본 논문에서는 ISO-9705 공간의 2/5 스케일 축소모형에 대한 화재 실험에서 측정된 고온 상층부의 연소가스 농도를 혼합분율 개념을 도입하여 분석함으로써 환기부족 상태의 실내화재에서 발생되는 연소생성물의 특성을 파악하고자 한다. 화재실 내부 고온 상층부의 두 지점에서 측정된 잔존 탄화수소, 일산화탄소, 이산화탄소, 산소, 수트(soot) 등의 성분비를 혼합분율의 함수로 내어 분석하였다. 또한 탄화수소 연료의 이상적인 반응에 근거한 상태 관계식과 비교함으로써 환기부족 화재에서 혼합분율 모델의 적용성을 분석하였다. 혼합분율 분석을 이용함으로써 측정된 수많은 데이터들을 화재 크기나 측정 위치에 상관없이 하나의 파라미터에 대해서 정리하여 전체적으로 분석할 수 있었다. 또한 혼합분율 분석에서 수트를 고려하는 것이 분석의 정확성을 크게 향상시킴을 확인할 수 있었다.

  • PDF

A Study on Characteristics of Fire in Vertical Space Using CFAST (화재시뮬레이션을 이용한 수직공간의 화재특성 분석 연구)

  • Park, Hyun-Jun;Kwon, Jin-Suk;Choi, Jae-Hyouk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.190-190
    • /
    • 2011
  • 사회 다변화 및 급속한 경제성장과 도시밀집화로 인하여, 화재의 발생으로 인하여 막대한 인명피해 및 대규모의 재산상의 피해가 지속적으로 발생하고 있다. 이러한 화재의 피해를 예측하기 위해서는 실제 규모의 화재실험이 매우 유용하지만, 막대한 비용과 현실적 제약조건으로 인하여 실제 실험에는 많은 어려움이 따른다. 따라서 막대한 예산이 소요되는 실제규모의 화재실험의 대체방법으로 실제를 모사하는 축소모형 화재모의실험 및 컴퓨터를 이용한 화재 시뮬레이션 기법이 널리 이용되고 있다. 본 논문에서는 범용 컴퓨터를 이용한 화재 시뮬레이션 기법(CFAST)을 이용하여 수직 공간 구성을 가지는 단독주택의 화재 성상을 검토하였다. 시뮬레이션 모델로는 단독주택을 대상건물로 하여 2층으로 수직 공간을 가지는 단독주택 건물에 대한 모의 화재 시뮬레이션을 수행 하였다. 화재 시뮬레이션 결과는 각 구획실별 온도, 일산화탄소량, 공기 중 산소량 등을 도출하여 기존 이론에 의한 화재성장 그래프와 시뮬레이션 데이터를 비교하여 정확도를 검토하였다. 본 논문에서는 두가지의 시나리오를 작성하여 화재 시뮬레이션 프로그램의 결과 값을 분석하였다. (1) 시나리오 1 : 화재시뮬레이션 대상건물 1층 거실(2번방)에서 스프링클러 미 설치시 화재가 발생한 경우를 가정하여 수평방향인 3번방과 수직방향인 7번방의 화재 확산 피해정도를 살펴보고, 화재 그래프의 이론값과 실험값의 차이를 비교하여 그 정합성을 검토하였다. 발화물질은 Curtain, TV set, Sofa, Table으로 하며 시간은 60초 간격으로 총 3600초(1시간)를 분석 하였고, 발화지점의 온도, 일산화탄소, 공기중 산소 농도를 분석하였다. (2) 시나리오 2 : 시나리오 1과 동일한 화재발현 조건으로 스프링클러가 설치되어 있을 때 화재 발생 했을 경우, 수평방향인 3번방과 수직방향인 7번방의 화재 확산 피해를 시나리오 1과 비교 검토 하였다. 기존 이론에 의한 화재 성장 그래프와 이번 시뮬레이션 결과값을 토대로 만든 그래프 형태를 비교해보면 두 그래프의 형태가 비슷한 형태를 나타내어 Flash Over 현상과 Back Draft 현상이 이론값과 같은 경향을 나타내고 있음을 확인 할 수 있었다. 따라서, 본 논문에서 수행한 화재 시뮬레이션 기법으로 건축물의 실제 화재시의 피해정도를 예측하는 데 유용하게 활용될 것으로 판단된다.

  • PDF

Effects of Initial Condition and Opening Geometry of a Compartment on the Gravity Current in the Backdraft (백드래프트의 중력흐름에 미치는 구획실 내부 초기조건 및 개구부 형상의 영향)

  • Park, Ji-Woong;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.18-25
    • /
    • 2015
  • Computational study of a gravity current prior to the backdraft was conducted using fire dynamic simulator (FDS). Various initial conditions of mixture compositions and compartment temperature as well as four opening geometries (Horizontal, Door, Vertical, and Full opening) were considered to figure out their effects on the gravity current. The density difference ratio (${\beta}$) between inside and outside of compartment, the gravity current time ($t_{grav}$) and velocity ($v_{grav}$), and non-dimensional velocity ($v^*$) were introduced to quantify the flow characteristics of the gravity current. Overall fluid structure of the gravity current at the fixed opening geometry showed similar development process for different ${\beta}$ conditions. However, $t_{grav}$ for entering air to reach the opposed wall to the opening geometry increased with ${\beta}$. Door, Vertical, and Horizontal openings where openings are attached on the ground showed similar development process of the gravity current except for Horizontal opening, which located on the middle of the opening wall. The magnitude of $v_{grav}$ at fixed ${\beta}$ was, from largest to smallest, Full > Vertical > Door > Horizontal, but it depended on both the size and location of the opening. On the other hand, $v^*$ was found to be independent to ${\beta}$, and only depended on the geometry of the opening.

An Experimental Study on the Damage of the Data Process Equipment When $CO_2$ is Discharged ($CO_2$ 소화설비 방사시 정보저장장치의 저온손상에 관한 연구)

  • 이수경;김종훈;김영진;최종운
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.19-26
    • /
    • 1999
  • $CO_2$ extinguishing system is the most $\phi$pular among the gas extinguishing system. $CO_2$ is usually stored with liquified state. But, it gasifies at the tip of nozzle when $CO_2$ was released through the pipe and head. A ro$\alpha$n temperature is very low when $CO_2$ was released. So electrical instrument, magnetic storage equipment and memory semiconductor are electrically or physically injured by cooling effect in a few minutes. So, we intend to find out temperature profile and electrical damage in compartment area, and supply basic d data for research and making standards and code through the full scale experiment. As result of experiment on the damage due to cooling effect from $CO_2$ extinguishing system, i instantaneous discharging temperature. was $-82.5^{\circ}C$ in average. An average temp. in the compartment after discharging $CO_2$ was $-40^{\circ}C$.

  • PDF

A Study on the Planning Characteristics of Contemporary Japanese Middle School Architecture (현대 일본 중학교 건축의 계획특성에 관한 연구)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.668-676
    • /
    • 2016
  • This study reviewed the planning characteristics of contemporary Japanese middle school architecture on which related studies are insufficient, aiming to obtain new ideas for planning Korean middle school facilities. Fourteen case schools built after 1990s were selected and analyzed. They were divided into learning-living space and other major spaces. The planning characteristics of the case schools are summarized as follows 1) The case schools were classified into two categories, departmentalized classroom type (D type) and usual with variation type (UV type) by school system. These categories can also be the classification standard for basic architectural characteristics in learning and living space of case schools. 2) D type case schools have departmentalized classrooms, home base, media space and teacher's space for learning-living space. D type case schools are divided into 'attached-to-classroom type' and 'separate type' depending on the adjacency of the home base and departmentalized classroom. 3) UV type case schools have multipurpose space around the classroom for learning-living space and can be divided into two types, i.e., 'directly adjacent' and 'separate', depending on the connectivity to classroom of multipurpose room. 4) Specialized classrooms are designed to have the openness to the public and the own characteristics of school subjects strengthened and show the spatial differentiation with connected ancillary spaces. 5) Libraries are designed as complex zones grouped with computer labs, audio visual rooms and multipurpose halls not as a single room and as open plan not with a closed wall. 6) The gymnasium is the basic sports facility with a martial arts room and outdoor pool, which are for after-school activities as well as physical education class. 7) The terrace, balcony and outdoor stairs are frequently used architectural vocabularies as diverse outdoor spaces with a variety of functions.

특정 실험실 조건에서의 사무실용 낮은 칸막이의 소음감쇠성능 측정방법 KS제정을 위한 ISO 규격내용 분석

  • Yang, Kwan-Seop;Jeong, Seong-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.21-24
    • /
    • 2006
  • 대부분의 사무용 건물은 코아 부분(엘리베이터 홀, 화장실, 계단 등)을 제외하고는 Open 되어 있으며, 필요에 따라 부서간에는 천장 면까지 도달하는 경량벽체를 설치하여 독립된 공간을 구획하고, 부서내부에서는 직원들간의 커뮤니케이션은 용이하게 하는 대신에 최소한의 독립성을 제공하기 위해 낮은 칸막이 등을 설치하고 있다. 그러나 사무실에 사용하는 칸막이 벽체 중 천장 면까지 도달하는 칸막이에 대해서는 KS F 2808(건물 부재의 공기전달음 차단성능 실험실 측정방법)의 측정방법을 이용하여 차음성능을 확인할 수 있으나 낮은 칸막이에 대해서는 소음저감 성능을 측정할 수 있는 측정 방법에 관한 규격이 없다. 따라서 기존에 있는 모든 KS 규격들은 국제표준규격인 ISO와의 부합화가 이루어졌거나 이루어지고 있기 때문에 이러한 정부의 방침에 따라 본 낮은 칸막이에 대한 소음감쇠량 측정규격 또한 ISO규격(ISO 10053(음향- 실험실 조건에서의 사무실 스크린의 소음저감성능 측정방법))을 받아들이기 위해 ISO규격 내용을 검토하였다. 향후 이 규격이 그대로 우리나라 규격으로 제정될 때 나탈 수 있는 문제점을 최소화하기 위해 국내에 있는 반 무향실에서 낮은 칸막이의 실제 소음저감 성능을 실시할 계획이다.

  • PDF