• Title/Summary/Keyword: 구조 불확도

Search Result 24, Processing Time 0.026 seconds

Robust Aeroelastic Analysis considering a Structural Uncertainty (구조 불확도를 고려한 강건 공탄성 해석)

  • Bae, Jae-Sung;Hwang, Jai-Hyuk;Ko, Seung-Hee;Byun, Kwan-Hwa
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.781-786
    • /
    • 2015
  • An aeroelastic stability can be degraded due to an aeroelastic modeling error and a structural uncertainty. Therefore it is necessary to predict the aeroelastic stability boundary considering an aeroelastic modeling error and a structural uncertainty. Robust aeroelastic analysis was proposed to predict the aeroelastic stability boundary considering these error and uncertainty. In the present study, the robust aeroelastic modeling and analysis were performed by using the ${\mu}$ analysis technique and the aeroelastic model of the control fin with modal approach and MSA. The computer program for the robust aeroelastic analysis was developed and verified by comparing its results with those of conventional aeroelastic analysis methods.

Assessment of ADCP discharge measurement uncertainty by GUM framework through large scale experiment (실규모 실험을 통한 GUM 기반의 ADCP 유량 측정불확도 산정)

  • Kim, Jong Min;Kim, Dong Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.18-18
    • /
    • 2021
  • 초음파 도플러 유속계(ADCP)는 초음파를 이용하여 하천의 유속 및 수심을 측정하는 장비로 기존의 지점식 유속계와는 다르게 수심방향 유속분포와 수심을 한번에 측정하게 되며, 보트를 이용하여 하천을 횡단하게 되면 기존의 유속-면적법을 이용하는 방식보다 간편하고 빠르게 한 단면의 유량을 측정할 수 있다. 이와 같은 이점으로 인해 국내뿐만 아니라 해외에서도 대하천에서부터 중·소규모의 하천까지 다양한 범위에서 유량을 측정하는 장비로서 사용되어지고 있다. ADCP의 측정 유량은 유량관측소에서 수위-유량관계식을 구축할 때 사용하고 있으며, 이렇게 제공되는 유량은 하천의 중·장기 계획 수립, 수공구조물의 설계 및 수문·수리분야의 연구에 활용되고 있다. 하지만 ADCP의 유량측정은 ADCP의 미측정 영역의 유량 추정, ADCP 잠김깊이의 정확도, 하안에서의 고정 측정시간 등 ADCP의 측정 과정이나, 유량 추정 방법에 따라 영향을 받게 되며. 이외에도 하천의 수심, 하상의 상태와 같은 측정 조건에 따라서도 정확도의 변화가 발생할 수 있다. 측정결과의 정확성을 향상시키고, 신뢰도가 높은 자료를 제공하기 위해서는 ADCP의 유량 측정결과에 대한 불확도를 발생시키는 요인들에 대한 분석과 이를 감소시킬 수 있는 방법을 찾는 것이 중요하다. 1993년 ISO, BIPM, IFCC 등 6개 기구에서는 측정불확도를 산정하기 위한 측정불확도 산정 지침서(GUM, Guide to the expression of Uncertainty of Measurement)를 제시하였다. GUM 표준안은 측정과정에서 발생하는 다양한 불확도 요인들을 불확도 전파법칙을 통해 전체 불확도를 산정하는 방식으로 WMO와 ISO의 유량 측정분야에서도 GUM 표준안을 측정불확도 산정 기준으로 공인하여 사용하고 있다(JCGM 100, 2008; ISO 25377, 2020). 이에 본 연구에서는 GUM 표준안을 이용하여 ADCP로 측정된 유량의 측정불확도를 산정하는 방법을 개발하고 각 요인들에 대한 실험 및 분석을 진행하였다. ADCP의 측정 정확도를 분석하기 위한 실험은 자연에 가까운 형상을 모의하고 있고, 소하천 규모를 갖고 있는 하천연구센터에서 수행하였으며, 요인들에 대한 분석 방법 및 총 불확도를 계산하는 방법에 대하여 제시하였다.

  • PDF

Estimation of confidence interval in exponential distribution for the greenhouse gas inventory uncertainty by the simulation study (모의실험에 의한 온실가스 인벤토리 불확도 산정을 위한 지수분포 신뢰구간 추정방법)

  • Lee, Yung-Seop;Kim, Hee-Kyung;Son, Duck Kyu;Lee, Jong-Sik
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.4
    • /
    • pp.825-833
    • /
    • 2013
  • An estimation of confidence intervals is essential to calculate uncertainty for greenhouse gases inventory. It is generally assumed that the population has a normal distribution for the confidence interval of parameters. However, in case data distribution is asymmetric, like nonnormal distribution or positively skewness distribution, the traditional estimation method of confidence intervals is not adequate. This study compares two estimation methods of confidence interval; parametric and non-parametric method for exponential distribution as an asymmetric distribution. In simulation study, coverage probability, confidence interval length, and relative bias for the evaluation of the computed confidence intervals. As a result, the chi-square method and the standardized t-bootstrap method are better methods in parametric methods and non-parametric methods respectively.

Comparison of Geometrical Factors of Dielectric Resonators Prepared for the Surface Resistance of Superconductor Films: Field Analysis vs. Computer Simulation (초전도체 박막의 표면저항 측정용 유전체 공진기에 대한 Geometrical factor의 비교 : 전자기장 해석 대 시뮬레이션)

  • Yang, Woo-Il;Jung, Ho-Sang;Kim, Myung-Su;Cho, Man-Soon;Choo, Kee-Nam;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2011
  • In the dielectric resonator method, which has been widely used for measuring the microwave surface resistance of superconductors, accuracies in the geometrical factors (G-factors) affect the uncertainty in the measured surface resistance. We compare the G-factors of short-ended sapphire resonator as obtained by using field analysis with those by using computer simulations: The former is obtained by using the analytic expressions for the electric and the magnetic field components inside the resonator, and the latter by using computer software. The G-factors as obtained by using the latter appear to be closer to those obtained by using the former as the resonator space is divided into larger number of sub-space, i.e., a tighter mesh, with a difference of ~8 % observed for a mesh of 14400 sub-spaces reduced to ~2 % for 114996 sub-spaces. Variations in the relative uncertainty in the surface resistance of typical $YBa_2Cu_3O_{7-\delta}$ superconductor films with those in the G-factors are studied, which provides an upper limit of the relative uncertainty in the G-factors required for realizing the target uncertainty in the surface resistance. These results could be useful in estimating the optimum number of meshes for obtaining the G-factors through computer simulations.

The comparison of angular dependence for optical stimulated luminescence dosimeter(OSLD) and electronic personal dosimeter(EPD) used in Diagnostic Radiology (영상의학과에서 사용되는 광자극 형광선량계와 전자식 개인선량계의 방향 의존성 비교)

  • Kwon, Soon-mu;Park, Jeong-kyu;Kim, Boo-soon
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.463-470
    • /
    • 2015
  • The angular dependence of active dosimeters, EPD, is analysed and compared with that of passive dosimeters, OSLD, after evaluating their relative response and uncertainty of measurement, where it is known that the personal use of them has been increased recently. There appeared a minor variation for average relative response of OSLD in the horizontal and vertical directions within the range $0^{\circ}{\sim}{\pm}90^{\circ}$, which are 0.97 and 0.95 respectively. The variations of angular dependence in the same situations with OSLD are 0.65 and 0.62, respectively, which also reveals a negligible effect on the overall uncertainty. EPDs within the interval $0^{\circ}{\sim}{\pm}60^{\circ}$ for horizontal and vertical directions are 0.94 and 0.97, respectively. These satisfy the requirements of IEC 61526. Uncertainties about the dependence of direction from horizontal and vertical directions are 0.44, 0.40, respectively. The impact of these uncertainties on the overall uncertainty was negligible. However, we observed a significant change in reactivity: the relative reactivities for $+90^{\circ}$ and $-90^{\circ}$ from the horizontal direction are 0.60, 0.37, while that form vertical direction is 0.06. The direction dependence of OSLD was superior to EPD in the range of $0^{\circ}{\sim}{\pm}90^{\circ}$. There appeared a rapidly changing structural features in EPD response for a certain direction. Therefore, we conclude that concurrent use of passive dosimeters and auxiliary dosimeter provides accurate data for personal dose measurements.

Uncertainty Analysis of various soil moisture measurement in mountains. (산지 토양수분량의 불확실성 분석)

  • Kim, Kiyoung;Lee, Yeongil;Jung, Sungwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.316-316
    • /
    • 2019
  • 최근 빈번한 자연재해로 인해 기상 및 지구물리학적 요소들을 관측하는 연구들이 활발히 진행되고 있으며, 그중 지표와 기상을 연결해주는 토양수분 관측은 지구에서 일어나는 현상에 대한 이해도를 높이기 위한 중요한 요소로써 인식되고 있다. 이러한 토양수분 자료는 지난 몇 년 동안 다양한 측정 방법과 알고리즘 개발이 이루어져왔으나 이러한 방식으로 산출된 데이터를 무분별하게 이용하기에 앞서 최적의 사용을 위해 오류 구조를 파악하고 정량적으로 측정하는 분석이 필요하다. 따라서 Triple collocation(TC) 기법을 활용하여 가상의 실제값(hypothetical truth)을 가정하고 각각의 산출데이터의 측정 불확도와 상관성을 추정할 수 있다. 본 연구에서는 인공위성, 모델자료와 같은 측정 방법뿐만 아니라 지점에 설치하여 물리적인 방법을 통한 토양수분 산출방식에도 관측상의 오차가 존재함을 인지하고, 이러한 오차가 존재하는 다양한 데이터들을 분석하였다. 이용된 데이터는 설마천 산지 사면에 설치된 유전율식(TDR, Time Domain Reflectometer) 측정장비, Cosmic-Ray newtron Probe, Noah 지표모델을 활용한 자료 동화 자료인 Global Land Data Assimilation System (GLDAS)를 입력 자료로 하여 TC 기법에 적용하였다. 분석 결과는 유역의 토양수분 관측에 대한 다양한 방법의 불확실성을 규명하는데 가장 중요한 연구로써 활용될 것으로 기대 된다.

  • PDF

Investigation of thermal deformation of wing skin induced by temperature gradient (온도 구배에 의한 날개 외피의 열변형 특성 연구)

  • Kim, Jeong-Beom;Kim, Hong-Il;Kim, Jae-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.10
    • /
    • pp.896-901
    • /
    • 2015
  • The skin-frame type structure is designed to investigate the thermal deformation of the wing skin induced by the temperature gradient. In order to effectively simulate the temperature gradient on the wing specimen, a water cooling system is devised on the frame of the specimen. Out of surface skin deformation of the skin-frame type structure made of SUS304 material with respect to the temperature is successfully measured using the digital image correlation (DIC) technique including quantitative evaluation of the measurement uncertainty.

Calibration and Performance Test of Electro-optical Distance Meters Using a Laser Interferometer (레이저 간섭계를 이용한 광파거리측정기의 교정과 특성분석)

  • Kim Jae Wan;Eom Tae Bong;Suh Ho Suhng
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.4
    • /
    • pp.367-374
    • /
    • 2004
  • In order for the measurement results of an electro-optical distance meter(EDM), which is widely used in surveying, to be reliable, an EDM should be calibrated. For the calibration of an EDM, we have settled a traceability chain, which connects the EDM under calibration to the definition of metre. The chain starts from the iodine stabilized He-Ne laser which realizes the definition of metre, and then connected to a stabilized laser interferometer, a standard EDM, and finally to the EDM under calibration through the baseline. We achieved the expanded calibration uncertainties of the scale and length measurement of an EDM being evaluated to be 6$\times$10$^{-6}$ and 0.2 mm, respectively. Two different calibration methods, and their results are compared.

Met-tower Shading Correction Program KIER-$ShadeFree^{TM}$ (풍황탑 차폐영향 보정 프로그램 KIER-$ShadeFree^{TM}$)

  • Kim, Hyun-Goo;Jeong, Tae-Yoon;Jang, Moon-Seok;Jeon, Wan-Ho;Yoon, Seong-Wook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.190.1-190.1
    • /
    • 2010
  • 풍력자원평가를 위해 풍력단지 개발대상지의 국지풍황 대표지점에 설치하는 풍황탑(met-tower 또는 풍황마스트; met-mast)은 모노폴(monopole), 삼각단면 트러스 또는 사각단면 트러스 구조를 갖는다. 풍향계 및 풍속계는 이러한 지지구조물에 의한 풍속의 교란 또는 차폐영향을 최소화하기 위하여 긴 붐(boom)의 끝단에 설치되지만 계측기가 풍황탑의 직후방 후류영역에 놓이게 될 경우 차폐영향을 완전히 피하기는 어렵다. 저자들의 선행연구에 따르면 풍황탑 차폐영향은 평균풍력밀도의 경우 2.5% 이상의 오차를 유발할 수 있으므로 풍력자원평가 시 필히 고려되어야 할 불확도 요인인 것이다. 이에 한국에너지기술연구원에서는 풍황탑 주위의 대기유동장을 전산유동해석을 이용하여 차폐영향의 정도를 정량적으로 수치모사함으로써 이를 보정하는 기술을 개발한 바 있다(현재 특허심사 중). KIER-$ShadeFree^{TM}$는 이 특허기술을 프로그램화 한 것으로, 시범적으로 다수의 풍황탑 풍력자원 측정자료에 적용하여 상당한 보정효과에 의한 풍력자원평가의 정확도 향상효과를 볼 수 있었다.

  • PDF

XRR용 두께 표준물질 제작을 위한 박막성장 및 특성평가

  • Yu, Byeong-Yun;Bin, Seok-Min;Kim, Chang-Su;O, Byeong-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.141-141
    • /
    • 2012
  • X-선 반사율 측정법(XRR)은 비파괴적인 측정방법과 수 nm의 두께를 정밀하게 측정할 수 있는 장점으로 인하여 반도체 산업현장에서 많은 관심과 연구가 이루어지고 있다. 이러한 XRR은 두께 분석 측정의 정밀도를 향상시키고 부정확한 결과를 방지하기 위하여 측정기기를 검증하고 보정할 수 있는 두께 표준물질을 필요로 하고 있다. 본 연구에서는 XRR용 두께 표준물질을 이온빔 스퍼터링 증착방법을 이용하여 제작하였다. 두께 표준물질 제작에 있어 공기 중 노출에 의해 산화가 되지 않는 산화물 박막과 산화물 기판을 선택하였다. 후보물질은 glass, sapphire, quartz, SiO2기판과 HfO2, Ta2O5, Cr2O3 산화물 타켓을 이용하여 박막을 제작하였다. 제작된 후 보물질은 교정된 XRR을 통하여 박막의 두께, 계면 및 표면 거칠기, 밀도등 박막의 구조특성분석을 하였다. Glass, quartz의 경우 기판 표면 거칠기가 좋지 않아 제작된 샘플의 X-선 반사율 곡선이 급격히 떨어지면서 측정되는 각도의 영역이 작아졌다. Sapphire로 제작한 시편은 측정된 데이터와 simulation의 curve fitting이 양호하지 않았다. 이 중 SiO2기판을 사용하고 HfO2박막을 증착한 샘플이 다른 후보물질보다 XRR curve fitting 결과가 가장 양호하여 두께 표준물질로 응용하기에 적절하였다. 그리고 AFM (Atomic Force MicroScope)을 이용하여 기판의 거칠기 및 증착한 박막표면 거칠기 측정을 하였고, TEM (Transmission Electron Microscope)으로 두께 측정을 하여 XRR로 얻은 데이터와 비교하였다. 이러한 결과를 토대로 XRR용 두께 표준물질 제작할 수 있었고, 추후 불확도 평가 및 비교실험을 통하여 제작된 XRR용 두께 표준물질을 이용할 수 있을 것으로 기대된다.

  • PDF