• Title/Summary/Keyword: 구조 감쇄

Search Result 186, Processing Time 0.024 seconds

Improvement of Functional Assessment for Riverine Wetlands using HGM Approach (HGM 적용을 통한 하도습지의 기능평가 제고 방안 연구)

  • Yeum, Junghun;Kim, Taesung
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.378-385
    • /
    • 2016
  • This study aims to suggest the framework of functional assessment on lotic area based on HGM(Hydrogeomorphic) approach targeting Wetland Protected Areas which are in the type of river channel, and to set up the fundamental data as a reference wetland. A total of 10 factors in terms of hydrology, biogeochemistry, plant habitat and animal habitat was analyzed based on the original approach of HGM and each Functional Capacity Index(FCI) of those factors was calculated. As the result of the modified FCI analysis, Damyang riverine wetland which is with artificial river bank had high values in the variables of area ratio of actual vegetation in the foreland, the number of plant per area and the area ratio of Salix spp., and those values were highly reflected on the factors of Nutrient Cycling(947,668.00), Species Richness and Maintain Characteristic Plant Communites(6.39) and Maintain Spatial Structure of Habitat(11.00). The Hanbando wetland which is keeping the natural bank had higher values in the variables of structural scale and species diversity, and the those values were highly reflected on the factors of Energy Dissipation(17,805.16), Subsurface Storage of Water(0.54), Removal of Imported Elements and Compounds(103,052.73), Maintain Characteristic Detrital Biomass(2.31), Maintenance of Interspersion and Connectivity (6.50), Species Diversity of Benthic macro-invertebrates(1.60) and Species Diversity of Vertebrate & Species Number of Other Animals(2.52/ 151.50), compared to the Damyang Riverine Wetland.

New Gain Function Based on Attenuation Characteristics of Ballast Track for GPR Analysis (GPR 분석을 위한 자갈궤도 자갈의 감쇄특성을 이용한 이득함수 개발)

  • Shin, Jihoon;Choi, Yeongtae;Jang, SeungYup
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.13-21
    • /
    • 2017
  • Ballasted track has been used as track system for more than 100 years. Ballasted track has advantages of low construction cost, flexible maintenance, low noise and vibration, and so on. However, ballasted track leads to continuous settlement which causes maintenance. Recently, increase in speed, traffic volume, and weight of train requires more frequent maintenance. Fouling, well-known phenomenon of accumulation of fine materials due to intrusion of subgrade and breakage of ballast materials, expedites the settlement (i.e., irregular settlement) of track. Ground Penetrating Radar (GPR) can be one of non-destructive tools that can evaluate fouling level of ballast. In this paper, a gain function based on the attenuation characteristics of ballast material is suggested in conjunction with Hilbert transform. Lab box tests and full-scale tests indicate that the suggested method reasonably classifies clean, fouled layers, and subgrade. However, additional study to eliminate effect of sleeper and to include the scattering features of the electromagnetic wave in ballast voids should be required in order to enhance the accuracy.

A Study on Analysis of Real Response of Steel Railway Bridges (강철도교의 실응답해석에 관한 연구)

  • Chang, Dong Il;Choi, Kang Hee;Lee, Hee Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.43-54
    • /
    • 1989
  • In this paper, measured and calculated responses are compared in order to give how the static and dynamic responses occurred in steel railway bridges due to train loads could be calculated appropriately. From this, it is investigated how the impact factors are varied by changing the train speed above 100km/h Field measurement is carried out by the steel strain gages and displacement transducers at the main design points, and then the static and dynamic response, fundamental frequencies, damping ratios and impact factors of the bridges are obtained. Static analysis is done using the computer program developed according to three dimensional matrix structural analysis in which the trains and bridges are modelled as 1,2 and 3 dimensions. Dynamic analysis is done according to 2 approaches, the moving force and mass problem. In moving force problem, the solutions are obtained by the modesuperposition-method and in moving mass problem by the direct integration method. From this study, it is known that in order to obtain the static response in the railway bridges, the bridge could be modelled by 1 or 2 dimension as in the highway bridge, however the response ratio(measured/calculaled) is high comparing to the highway bridges. By the way, the dynamic response should be obtained by the moving mass problem. And by comparing the measured and code specified impact factors, it is known that the factors specified in the present railway bridge code are very safe under the present service speed below 100km/h. However, because the factors become very high under the speed above 100km/h, especially in the simple plate girder bridge, it is thought that the code specification on impact factor should be discussed enough under the rapid transit system.

  • PDF

Analysis on the EMC evaluating method for applying wireless communications in NPP (원전 내 무선통신 적용에 대한 전자파 적합성 평가방법 분석)

  • Kang, SeungSeok;Lim, Tae Heung;Choo, Jaeyul;Kim, HyungTae;Kim, DaeHee;Byun, Gangil;Park, Jong Eon;Lee, Jun-Yong;Choo, Hosung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2221-2231
    • /
    • 2017
  • In this paper, we surveyed previous cases, network protocols (such as Wi-Fi, Zigbee, Z-wave, and WirelessHart) and propagation characteristics on the application of maintaining equipments for instrumentation and control (I&C) using wireless communication techniques inside the nuclear power plant (NPP). In addition, we compared and analyzed the difference of detailed regulations with respect to the electromagnetic interference (EMI) and radio frequency interference (RFI) in the Regulatory Guide 1.180 rev. 1 (RG. 1.180) for adopting the wireless communication techniques inside the NPP, and other regulations, such as MIL-STD 461E and IEC 61000-4, that are recognized in the KINS/RG-N03.09 (Rev. 2). Furthermore, we investigated evaluating factors about electromagnetic properties by considering indoor environments, wave scattering, shielding effectiveness, and the indoor wave attenuation model that were not included in the current electromagnetic compatibility regulation.

A Study on Apparatus of Human Body Antenna for Mine Detection (지뢰탐지용 휴먼바디 안테나 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.269-272
    • /
    • 2015
  • this is the study of the human body antenna device which can detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal using superhigh frequency RF beam equipped with the body. and it is able to transmit the data of the detection of the powder, battle combats can share that among them. with its flexible roof radial antenna structure, it emits the superhigh frequency RF beam to the front and flank multiply, preprocesses through the powder preprocessing part. and with the non-linear regression model algorism engine part, reflecting the attenuation characteristics depend on the delayed time of degree of the signal power which is received to the superhigh frequency RF beam. so it is able to detect the signal of the most likely mine or powder based on the degree of the answer signal power according to the delayed time of the superhigh frequency RF beam. also, it can detect the powder whether it is metal or nonmetal, mine, dud, VBIED. it can increase the chance of detection about 90% more than existing mine detector.

Preparation and Characterization of Ferrite Supported on Porous Ceramic Fiber Composites for Co2 Decomposition (이산화탄소 분해용 페라이트 담지 다공성 세라믹 섬유복합체 제조와 물성)

  • Lee, Bong-Soo;Kim, Myung-Soo;Choi, Seung-Chul;Oh, Jae-Hee;Lee, Jae-Chun
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.8
    • /
    • pp.801-806
    • /
    • 2002
  • The decomposition and/or conversion of carbon dioxide to carbon have been studied using oxygen-deficient ferrites for the reduction of $CO_2$ emission to the atmosphere. In this work, the homogeneous precipitation method using urea decomposition was employed to induce in situ precipitation of Ni ferrite($Ni_{0.4}Fe_{2.6}O_4$) on the porous ceramic fiber support (50 mm diameter${\times}$10 mm thickness). Effects of ferrite loading conditions on the CO2 decomposition efficiency were discussed in this paper. Removal of residual chloride ions and urea by solvent exchange from the porous media after ferrite deposition apparently helps to form spinel ferrite, but does not increase the efficiency of $CO_2$ decomposition. Porous ceramic fiber composites containing 20 wt% (1g) ferrite samples showed 100% efficiency for $CO_2$decomposition during the first three minutes, but the efficiency decreased rapidly after the elapsed time of ten minutes. The characteristic reduction time for the $CO_2$ decomposition efficiency was estimated as about 3∼7 min.

Path Loss Characteristics in Subway Tunnel at 2.65GHz (지하철 터널 환경에서 2.65GHz 대역신호의 경로손실 특성)

  • Jo, Han-Shin;Kim, Do-Youn;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10A
    • /
    • pp.1014-1019
    • /
    • 2006
  • The research deals with the measurement of electromagnetic wave propagation in subway tunnels at 2.65GHz. Measurements have been conducted in 4 different types of tunnel courses, a straight tunnel, two curved tunnels, with 245m and 500m radius of curvature, and a tunnel that has both straight and curved sections. we found that the path loss exponent for the line-of-sight(LOS) region inside all the tunnels is $1.31{\sim}2.19$. The path loss exponents for LOS regions in the tunnel is lower than $(3{\sim}4)$, which corresponds to the path loss exponent factor for outdoor cellular environments. The path loss exponents of the straight tunnel, two curved tunnels with 245m and 500m radius of curvature are 1.94, 2.92, and 4.34, respectively. This indicates that a smaller radius of curvature in tunnel results in a higher path loss exponent for nonline-of-sight(NLOS) region. The path loss exponents for the NLOS region in the combined and curved tunnel, which have the same radii of cuvature, are 5.88 and 4.34, respectively. Therefore, it can be concluded that the path loss characteristics in tunnel environments are infulenced by the radii of curvature as well as the LOS distance.

Diagnostic Imaging of Lipoma in the Retroperitoneum and Pelvic Cavity in a Dog (개의 후복강과 골반강에 발생한 지방종의 진단영상 증례)

  • Lee, Nam-Soon;Kim, Jun-Young;Na, Eung-Sic;Kim, Mi-Eun;Lee, Hye-Yeon;Choi, Mi-Hyun;Kim, Wan-Hee;Kim, Dae-Yong;Choi, Min-Cheol;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.88-92
    • /
    • 2010
  • An 11-year-old, spayed female, weighing 10 kg miniature Schnauzer was admitted for abdominal distension, anorexia, pollakiuria, and constipation. A large, homogeneous fat opacity mass was identified in the retroperitoneum and pelvic cavity on the abdominal survey radiography. The mass displaced the descending colon peripherally and ventrally, and the urinary bladder ventrally. On the abdominal ultrasonographic examination, the mass was uniformly hyperechoic with a coarse internal echo texture and had outer hyperechoic capsule, and it showed homogeneously same attenuation (-180 ~ -110 HU) as adjacent fat on the computed tomography. There was no evidence of invasion into the surrounding structures or organs. Cytological findings from fine needle aspirates were numerous sheets and clusters of adipocytes. The dog showed complete resolution of clinical signs after surgical resection of the mass. The mass was confirmed as simple lipoma through histopathological examination.

Correction of Beam Direction Error caused by Frequency Scan Effect in Active Phased Array Antenna for Satellite Communications (위성통신 능동 위상배열 안테나에서 주파수 스캔 효과로 발생하는 빔 지향 오차의 보상)

  • 전순익;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.413-420
    • /
    • 2003
  • In this paper, the correction method of antenna beam direction errors is introduced which caused by frequency scan effect in active Phased may antenna for satellite communications. The antenna makes the beam directional error from frequency scan effect when it has dual beam may structure with asymmetrical series connection, their frequencies are different and for from each other, their 3dB beamwidth is narrow, and scan range is wide. By proposed equations, estimated beam direction error angles can be calculated and active phase shifter control values also can be calculated to compensate them. In this paper, the active phased array antenna system was fabricated to measure beam direction errors both before and after correction, which has dual beam from 32${\times}$4 main level array and 4${\times}$2 second level array, frequency deviation 500 MHz max.(6.7 %) at 7.25 GHz∼7.75 GHz ranges, 0$^{\circ}$${\pm}$35$^{\circ}$nm ranges, and 35.6 dBi gain with 2.2$^{\circ}$3 dB beam width. Its beam direction error by frequency san effect which was 2.5$^{\circ}$max., was reduced to 0.2$^{\circ}$max. after correction. This was 7 dB improvement of signal loss. The active phased array antenna can accurately track the target satellite for communications by this proposed correction method.

Design of A Microwave Planar Broadband Power Divider (마이크로파대 평면형 광대역 전력 분배기 설계)

  • Park, Jun-Seok;Kim, hyeong-Seok;Ahn, Dal;Kang, Kwang-yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.651-658
    • /
    • 2001
  • A novel multi-section power divider configuration is proposed to obtain wide-band frequency performance up to microwave frequency region. Design procedures for the proposed microwave broadband power divider are composed of a planar multi-section three-ports hybrid and a waveguide transformer design procedures. The multi-section power divider is based on design theory of the optimum quarter-wave transformer. Furthermore, in order to obtain the broadband isolation performance between the two adjacent output ports, the odd mode equivalent circuit should be matched by using the lossy element such as resistor. The derived design formula for calculating these odd mode matching elements is based on the singly terminated filter design theory. The waveguide transformer section is designed to suppress the propagation of the higher order modes such as waveguide modes due to employing the metallic electric wall. Thus, each section of the designed waveguide transformer should be operated with evanescent mode over the whole design frequency band of the proposed microwave broadband power divider. This paper presents several simulations and experimental results of multi-section power divider to show validity of the proposed microwave broadband power divider configuration. Simulation and experiment show excellent performance of multi section power divider.

  • PDF