• 제목/요약/키워드: 구조연결

Search Result 4,849, Processing Time 0.042 seconds

Analysis of thermal changes in bone by various insertion torques with different implant designs (서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구)

  • Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.

Drying of Rough Rice by Solar Collectors (태양(太陽) 열(熱 )집열기(集熱機)를 이용(利用)한 벼의 건조(乾燥)에 관(關)한 연구(硏究))

  • Chang, Kyu-Seob;Kim, Man-Soo;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.264-272
    • /
    • 1979
  • The flat-plate and tubular soar collectors were designed and constructed for drying the rough rice, and the performance of the collectors and drying effect were investigated when rough rice was packed in grain bin connected to collectors. Average-monthly radiation on a horizontal surface based on bright sunshine in Daejeon area during 1978 was the highest as $16,814\;KJ/m^2{\cdot}day$ in May and the lowest as $4,254\;KJ/m^2{\cdot}day$ in December, and significane was not recognized between the calculated and recorded values. The thermal effciency of collectors were increased as radiation increased during drying period and the average thermal effciency of flat-plate and tubular collectors in 11 to 12 o'clock a.m were 28.12 and 16.75%, respectively. The average inlet temperature of grain bin at 12 o'clock was shown as 20.02 at control 40.5 at grain bin connected to tubular collector and $55.1^{\circ}C$ at grain bin connected to flat-plate collector. In 25 cm rough rice depth in grain bin, tim taken for drying from initial moisture content at 27.4 to decrease upto 17.0% (14.5 % on wet basis) were 32 in control, 18 in grain bin connected to tubular collector and 11 hrs to flat-plate collector, and grain depth influenced drying rate remarkably. In the view point of drying characteristics, drying pattern showed initially falling-rate to constant-rate period finally.

  • PDF

DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination (HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가)

  • Kwon, Ik-Soo;Hwang, Jae-Sang;Koo, Jae-Hong;Sakamoto, Kuniaki;Lee, Bang-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.

(A Scalable Multipoint-to-Multipoint Routing Protocol in Ad-Hoc Networks) (애드-혹 네트워크에서의 확장성 있는 다중점 대 다중점 라우팅 프로토콜)

  • 강현정;이미정
    • Journal of KIISE:Information Networking
    • /
    • v.30 no.3
    • /
    • pp.329-342
    • /
    • 2003
  • Most of the existing multicast routing protocols for ad-hoc networks do not take into account the efficiency of the protocol for the cases when there are large number of sources in the multicast group, resulting in either large overhead or poor data delivery ratio when the number of sources is large. In this paper, we propose a multicast routing protocol for ad-hoc networks, which particularly considers the scalability of the protocol in terms of the number of sources in the multicast groups. The proposed protocol designates a set of sources as the core sources. Each core source is a root of each tree that reaches all the destinations of the multicast group. The union of these trees constitutes the data delivery mesh, and each of the non-core sources finds the nearest core source in order to delegate its data delivery. For the efficient operation of the proposed protocol, it is important to have an appropriate number of core sources. Having too many of the core sources incurs excessive control and data packet overhead, whereas having too little of them results in a vulnerable and overloaded data delivery mesh. The data delivery mesh is optimally reconfigured through the periodic control message flooding from the core sources, whereas the connectivity of the mesh is maintained by a persistent local mesh recovery mechanism. The simulation results show that the proposed protocol achieves an efficient multicast communication with high data delivery ratio and low communication overhead compared with the other existing multicast routing protocols when there are multiple sources in the multicast group.

Classification of Cordyceps spp. by Morphological Characteristics and Protein Banding Pattern (동충하초(冬蟲夏草)(Cordyceps) 속균의 형태적인 특징과 단백질 Pattern에 의한 계통 분류)

  • Sung, Jae-Mo;Lee, Hyun-Kyung;Yang, Keun-Joo
    • The Korean Journal of Mycology
    • /
    • v.23 no.1 s.72
    • /
    • pp.92-104
    • /
    • 1995
  • Ten species of Cordyceps species were collected throughout Kangwon province including Chuncheon Dongsanmyun KNU forest experiment from June to September, 1993. Collected Cordyceps species were identified as Cordyceps militaris, C. roseostromata, C. kyushuensis, C. scarabaeicola, Phytocordyceps ninchukiospora, C. nutans, Paecilomyces tenuipes, C. sphecocephala, Hymenostilbe odonatae, Torrubiella sp.. C. militaris, type species of Cordyceps species, was mainly formed on pupae of Lepidoptera and found after the rainy season around July. Fruiting body of C. roseostromata was morphologically similar to those of C. militaris, but relatively small in size and they were also found on lawn or pupa of Lepidoptera. Fruiting body of C. scarabaeicola was found on adult Scarabaeidae specifically and collect fruiting bodies of C. kyushuensis were on larva of moth. C. nutans and C. sphecocephala had host specificity on Hemiptera and Hymenoptera, respectively. Each species formed elliptical fertile part attach to the slim and carneous stalk and they were collected the most in specimen number through whole season of the summer. Ascospore of Phytocordyceps ninchukiospora on seed was characterized by two viable, multiseptate, fusiform units linked end-to-end by a long, filiform connective. Paecilomyces tenuipes, imperfect stage of the genus Cordyceps is multi-infective fungi that attack all stages of all groups of insects. Hymenostilbe odonatae attacks only adult Odonata and Torrubiella sp. formed on spider was difficult to collect because it was found the back side of leaf. As results of cultural test PDA medium showed the best mycelial growth. In the experiment of effect of the acidity inside of the media, C. militaris was good on pH 5, C. nutans and Phytocordyceps ninchukiospora were good on pH 6 and Paecilomyces tenuipes was on pH 7 and C. scarabaeicola was on pH 9. All isolates tested showed the best mycelial growth at $20^{\circ}C$. Morphologically similar isolates were used to analyze protein banding pattern among and within species. As a result, C. militaris, C. roseostromata and C. kyushuensis were clustered into close species and C. scarabaeicola and Phytocordyceps ninchukiospora were relatively distant from those species.

  • PDF

Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

Studies on Mycoplasma-Like Organism Associated with Witches' Broom of Rhus javanica (I) (Mycoplasma 성(性) 붉나무빗자루병(病)에 관(關)한 연구(硏究) (I))

  • Kim, Young Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.47 no.1
    • /
    • pp.1-15
    • /
    • 1980
  • The occurrence of witches' broom of Rhus javanica was first noticed in Korea by the author in 1979. Subsequently, studies were made on the symptomatology, etiology, and transmission of the disease, as well as the effect of some antibiotics on the disease development. The results of these studies are summarized as follows: 1. Symptoms of the infected plant were characterized by dwarfing of the tree accompanied by yellowing and brooming of the foliage. 2. Electron microscopy of witches' broom diseased Rhus javanica plant revealed the occurrence of numerous mycoplasma-like organisms (MLO's) in the phloem tissue cells (sieve tube elements and phloem parenchyma cells) of the rachis and midribs of infected leaves. 3. The MLO's were bounded by a single unit membrane and contained ribosome-like granules and strands presumed to be DNA. It also appears that the MLO multiply possibly by budding as well as binary and plurinary fission. 4. In the midrib of healthy leaves, vascular bundles were collaterally discontinuous. In the diseased leaves, however, xylems were connected to each other and phloem cells showed an atrophy. Granules, which were prominent in the normal abaxial epidermis, were not observed in the peidermis of diseased leaves. 5. Electron microscopy revealed crystals or osmopholic granules in the phloem parenchyma cells, and that normal stacks of grana were not developed in the chloroplasts of infected levels. 6. The disease was experimentally transmitted by grafting. Budding was more effective than crown grafting for transmitting the disease. The disease has been transmitted by grafting even when complete union of stocks and scions has not taken place. The disease agent was not transmitted by sap inoculation. Insect transmission has not been confirmed. 7. Dipping the roots of infected plants into the 500 ppm and 1,000 solutions of either tetracycline HCI or oxytetracycline, HCI was more effective on temporary remision of the symptoms than spraying the 100 ppm and 200 ppm solutions of the same antibiotics. A greater effect was achieved through dipping into 1,000 ppm than into 500 ppm.

  • PDF

Need and Contents of Classical River Novels in Secondary Education - Focus on highschool literature textbooks (중등교육과정에서의 고전 대하소설 교육의 필요성과 내용 - 고등학교 『문학』 교과서를 중심으로)

  • Han, Gil-yeon
    • Journal of Korean Classical Literature and Education
    • /
    • no.32
    • /
    • pp.119-158
    • /
    • 2016
  • In this thesis we set forth the reasons for teaching classical river novels in secondary education, and investigated the guiding principles for content design of high school literature textbooks. Although classical river novels have great significance in cultural and narrative histories, they were previously consistently disregarded in secondary education. First, we looked at the need for including classical river novels in the secondary school curriculum to create a well-balanced education of classical novels, to link this with modern river novels, to teach the narrative styles and esthetics of river novels, and to let students understand the various cultures of the late Joseon Dynasty. Second, we examined two ways of educating students about classical river novels. For exclusively teaching classical river novels, we recommended the means of teaching and provided detailed guidelines by which they can be taught, as well as provided complete information about the family tree, the story unit, and the scene deployment. To establish the link between classic river novels and their modern counterparts, we recommended the process of teaching accession and transition of tradition by introducing the commonalities and the differences across three generations stories, besides discussing the viewpoints of female writers. When classical river novels are introduced in literary textbooks, students will realize the existence of such novels though they may not understand all aspects of the novels. We suggest that teaching and introduction of classical river novels in secondary education as soon as possible.

A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam (콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구)

  • Han, Kiseung;Lee, Seungho;Kim, Sanghoon;Kim, Sejin;Pai, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.10
    • /
    • pp.21-29
    • /
    • 2021
  • Most concrete gravity-type dams in and out of the country were constructed by column method to control cracks caused by concrete hydration heat generated during construction, resulting in a certain level of leakage after impoundment through various causes, such as contraction joints and construction joints. However, due to the characteristics of concrete structures that shrink and expand according to temperature, concrete dams have vertical joints and drains to allow penetration. PVC waterproof shows excellent effects in completion of the dam, which however increases the possibility of interfacial failure due to different thermal expansion. Other causes of penetration may include problems with quality control during installation, generation of cracks due to heat of hydration of concrete, waterproofing methods, etc. In the case of Bohyunsan Dam in Yeongcheon, North Gyeongsang Province, the amount of drainage in the gallery was checked and underwater, and it was confirmed that there are many penetrations from drainage holes connected to vertical joints, and that some of the PVC waterproofs are not fully operated. As a new method to prevent penetration through vertical joints, D.S.I.M. (Dam Sealing Innovation Method) developed by World E&C was applied to Bohyunsan Dam and checked the amount of drainage in the gallery. As a result of first testing three most leaking vertical joints, the drain in the gallery was reduced by 87% on the average and then applied to the remaining 13 locations, which showed a 83% reduction effect based on the total drain in the gallery. Summing up these results, it was found that D.S.I.M. preventing water leakage from the upstream face is a valid construction method to reduce the water see-through and penetration quantity seen in downstream faces of concrete dams. If D.S.I.M. is applied to other concrete dams at domestic and abroad, it is expected that it will be very effective to prevent water leakage through vertical joints that are visible from downstream faces.

Kinematics of the Northern Filament in Orion Molecular Clouds Complex Using 12CO Molecular Observation Data (12CO 분자선 관측 자료를 이용한 오리온 분자운 복합체내 북쪽 필라멘트의 운동학 연구)

  • Jo, Hoon;Sohn, Jungjoo;Kim, ShinYoung;Lee, JeeWon;Kim, Sungsoo S.;Morris, Mark
    • Journal of the Korean earth science society
    • /
    • v.39 no.6
    • /
    • pp.519-532
    • /
    • 2018
  • We investigated the effect of galactic plane toward molecular motion and kinematics in the northern filament (NF) of Orion Molecular Clouds Complex (OMC) using $^{12}CO$ (J=1-0) line. Observed data were from three areas including NF1, NF2, and NF3 in far-out order from galactic plane, for a total 270 hours by Seoul National University Radio Astronomy Observatory (SRAO) 6m telescope, with 2arcmin spatial resolution. galactic plane and OMC NF were connected to each other along the magnetic field at a density of 3% for $^{12}CO$ (J=2-1) and 9% for the case of dust. $^{12}CO$ (J=1-0), $^{12}CO$ (J=2-1), and interstellar dusts were distributed uniformly in NF3, but only in certain regions with relatively high density in NF1 and NF2. NF showed a single structure, partial shrinking motion in NF1, and rotational motion at the bottom of NF2, and spiral rotation associated with magnetic field only in NF3. The position-velocity analysis showed that the materials including $^{12}CO$ (J=1-0) could flow toward galactic plane along NF2 and NF3. However, there was no clear cause for the material to flow toward galactic plane in this result. Further detailed observation for rotational motion at the top of NF1 and NF2 might help to confirm it.