A Study on the Performance Measurement System for the Reinforced Concrete Structure Electromagnetic Shielding Wall (철근 콘크리트 구조 전자파 차폐 벽체에 대한 성능측정 시스템 연구)

  • Kim, Bo-Hyun;Cho, Kyeong-Yong;Park, In-Wook;Oh, Jae-Hyun;Lee, Sang-Hoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.492-498
    • /
    • 2021
  • In this paper, the electromagnetic wave transmittance of the reinforced concrete structure wall was analyzed using the performance measurement system of electromagnetic wave shielding. Recently, electromagnetic wave shielding technologies on the reinforced concrete wall conditions have been studied, and the shielding effectiveness have been tested on unit cell size. However, the unit cell size tests have problems on that the measurement range for shielding performance is insufficient and it is difficult to reflect the real conditions of the concrete wall. Therefore, we constructed a shielding performance measurement system using a large sample of 2.2m × 2.2m like a real wall. To verify the measurement system, general reinforced concrete test samples were selected, and real shielding performance measurements and numerical analysis were proceeded. Test and numerical analysis results showed similar tendencies in the evaluation frequency range of 75MHz to 2GHz. Thus we validated the effectiveness of this shielding performance measurement system.

Study on Development of a Carton Box for Cold-chain Distribution of Oyster mushroom(Pleurotus ostreatus) (느타리 버섯의 저온유통용 포장상자 개발에 관한 연구)

  • Lee, W. O.;Yun, H. S.;Lee, H. D.;Chung, H.;Cho, K. H.;Kim, M. S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.311-316
    • /
    • 2002
  • 느타리버섯의 포장상자를 예냉·저온유통에 적합한 구조로 개선하기 위하여 4kg용 골판지상자를 T11형 표준 팔레트에 적재율이 96%이상 되게 제작하여 고습조건에서도 안전하게 느타리버섯을 보호할 수 있는 상자구조를 찾기 위한 수직압축강도시험과 냉각성능 및 예냉후 저온저장 중 품질변화에 대한 시험을 실시하였다. 시험결과 4kg 접음식 상자에서 내 포장상자를 사용할 경우 고습조건에서 안전압축강도를 유지할 수 일었으며, 브릿스형 상자에 비하여 경제적으로 제작할 수 있고, 또한 홈판형 상자에 비하여 냉각속도를 단축하고 균일한 냉각을 할 수 있어 느타리 버섯의 품질유지에 유리한 것으로 나타났고, 기존 유통되는 상자을 사용할 때 보다 유통기간을 4∼5일정도 연장시킬 수 있는 것으로 나타났다.

  • PDF

텔레비전 수상기의 원리

  • Korea Electrical Products Safety Association
    • Product Safety
    • /
    • no.4 s.160
    • /
    • pp.54-57
    • /
    • 2007
  • tele는 그리스어로 '멀리', vision은 라틴어로‘본다’는 뜻이다. 1931년 미국에서 첫 시험방송이 시작되었고, 1937년에 영국의 BBC 방송국이 세계 최초로 흑백텔레비전 방송을 시작하였다. 한국은 1956년 5월 12일 세계에서 15번째로 TV전파를 발사하였다. 이러한 흑백텔레비전을 시작으로 예전과는 달리 요즘 가정에서는 대다수가 컬러텔레비전(color television)을 시청한다. 이번에는 몇 호에 걸쳐서 이러한 컬러텔레비전의 구조 및 원리 등에 대하여 알아볼까 한다. 먼저 발광의 원리, 방송의 구성, 수상기 및 튜너 등에 대하여 알아보고, 더 나아가 HDTV(High Definition Television : HDTV) 의 구조 및 원리에 대해서도 알아보도록 하겠다.

  • PDF

Seismic Qualification of Class 1E Battery by Combined Analysis and Testing (수치해석과 실험을 통한 안전등급 축전지의 내진검증)

  • 김영중;박성환;정태영;정정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.87-91
    • /
    • 1992
  • 축전지를 탑재한 프레임형 랙에 대한 공진탐색시험결과를 이용하여 유한요 소에 의한 수치해석모형을 결정하였다. 내진검증시험은 에이징시험을 거친 3 개의 축전지를 포함하여 28개의 축전지를 탑재한 시험랙을 대상으로 수행되 었다. 공진탐색시험으로부터 구한 모달특성치를 이용하여 지진응답을 해석하 였으며 실험치와 부합함을 확인하였다. 시험랙의 지진응답이 실제 설치될 60 개의 축전지를 갖는 전체랙의 응답보다 크므로, 시험랙에 의한 내진검증이 보다 열악한 조건에서 수행되었다고 볼 수 있다. 시험랙에 대한 내진검증시 구조부재의 구조적 안정성과 축전지의 성능유지를 확인한 바 있으므로 전체 랙의 경우에도 내진검증이 이루어졌다고 판단된다.

  • PDF

A study about frequency domain analysis of impact-wave for detecting of structural defects in the concrete structure (구조물의 안전진단을 위한 충격파의 주파수 영역 탐사에 관한 연구)

  • Suh Baeksoo;;Kim Hyoungjun;Lee Sangchul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.165-180
    • /
    • 2005
  • Impact seismic wave test is a method for nondestructive testing of concrete structure using of stress wave which is propagated and reflected from internal flaws within concrete structure and external surface, In this study, we performed non-destructive testing using impact seismic wave test for safety diagnosis of civil engineering structures. For this, I've compared and analized the result in the way of reflective method mostly using on one-dimension such as tunnel lining, and penetration method using the way of cross hole and tomography.

  • PDF

A Study on the Development of Integrated Folding Composite Wing Using Optimal Design and Multiple Processes (최적설계 및 다중공정을 적용한 일체형 접이식 복합재료 날개 개발 연구)

  • Lee, Jong-Cheon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.3
    • /
    • pp.70-78
    • /
    • 2018
  • This research was carried out to develop an integrated folding wing made from carbon composite materials. Design requirements were reviewed and composite wing sizing was conducted using design optimization with commercial software. Three composite manufacturing processes including hot-press, pultrusion, and autoclave were evaluated and the most suitable processes for the integrated wing fabrication were selected, with consideration given to performance and cost. The determined manufacturing process was verified by two design development tests for selecting the design concept. Stiffness and strength of the composite wing were estimated through structural analyses. The test loads were calculated and static tests about design limit load and design ultimate load were performed using both wings. As a result, the evaluation criterions of the tests were satisfied and structural safety was verified through the series of structural analyses and testing.

A Study on the Reliability of Detecting Reinforcement Embedded in Concrete in Various Factors Using Electromagnetic Induction Method and Electromagnetic Wave Method (전자기유도법과 전자파레이더법을 이용한 각종인자에 따른 철근탐사의 신뢰성에 관한 연구)

  • Kim, Jong-Ho;Oh, Kwang-Chin;Park, Seung-Bum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.179-186
    • /
    • 2008
  • Probing inside of concrete structures is one of the important steps in assessing condition of the structure. For the assessment, electromagnetic induction method and electromagnetic wave method are currently applied to the measurement of cover depth, and the detection of reinforcement embedded in concrete. To determine detection capability of locating reinforcement embedded in concrete, commercially available nondestructive testing (NDT) equipments have been tested. The equipments include electromagnetic wave system and electromagnetic induction system. In the tests, nine concrete specimens which have the dimensions of 1,000mm(length))${\times}$300mm(width) with thickness varying from 125mm to 150mm are used. The reinforcement are located at 45, 60, 100mm depth from the concrete surface. Horizontal reinforcement spacing has been set over 100mm. From the outcome, it is shown that error is increased as the diameter of reinforcement enlarge in case of using electromagnetic induction method. In case of using electromagnetic wave method, the detection of reinforcement embedded in deep is good in the view of reliability because of using the relative permittivity on the real cover depth.

용접부의 사전 풀질 관리를 위한 연속압입시험의 현장 적용

  • 손동일;장재일;전은채;권동일;박주승
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.331-336
    • /
    • 2001
  • 경제규모의 증대와 사용부지의 제한으로 인하여 용접구조물들은 복합화, 대형화 추세에 있고, 이러한 경향에 따라 구조물에서 용접부가 차지하는 비중 역시 증가하고 있다. 용접과정을 통해 다양한 금속학적, 역학적 변화를 경험하게 되는 용접부는 대형 강 용접 구조물/설비의 건전성을 확보하기 위해서 가장 주의를 기울여야 하는 평가 대상 부위임에 분명하다.(중략)

  • PDF

A study on thermal and mechanical properties according to the structures of conductor sleeve and the method of connection for EHV Cables (전력 케이블용 접속 슬리브의 구조 및 접속 방법에 따른 특성 연구)

  • Kim, Young-Bum;Han, Bong-Soo;Ryu, Jeong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1493_1494
    • /
    • 2009
  • 초고압 전력 케이블용 도체 접속을 위한 접속방법으로 압축형(compressing type), 용접형(welding type), 압축-용접형(CW type; compressing-welding type)의 슬리브는 물론 동과 알루미늄의 이종(nonidentical materials) 접속을 위한 슬리브를 개발 하였으며, 전기적, 기계적으로 검증된 제품 개발을 위하여, 슬리브의 구조 변경과 접속 방법의 차이뿐 아니라 접속 전후의 응력 평가를 위해 슬리브 시편의 인장시험(tensile strength) 결과에 따른 슬리브 제작 및 시험을 진행하였다. 신뢰성 있는 제품 개발과 데이터를 얻기 위하여 초고압용 지중 고압 케이블을 시험 시료로 적용하여 시험 선로(test loop)를 구성하였으며, 이를 통하여 구조와 재질에 따른 접속 방법, 이상 온도 상승 또는 국부적인 고온 부위 발생 여부 등의 전기 시험 및 열싸이클 전압 시험(heating cycle voltage test) 조건을 설정하여 시험 전후의 열신축 등 전기적, 기계적 특성을 평가하였다. 접속 슬리브의 구조 및 재질에 따른 위치별 발열 양상을 체크하였으며, X-ray 장비를 이용하여 슬리브 내부의 압축 및 충진 정도를 점검함으로써 기존 접속 슬리브 보완은 물론 개발된 접속 슬리브의 설계 기준 및 안전율을 설정 할 수 있었다.

  • PDF

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF