A Study on the Performance Measurement System for the Reinforced Concrete Structure Electromagnetic Shielding Wall  

Kim, Bo-Hyun (Safety Convergence Center, Korea Conformity Laboratories)
Cho, Kyeong-Yong (Department of Electrical and Electronic Engineering, Yonsei University)
Park, In-Wook (Safety Convergence Center, Korea Conformity Laboratories)
Oh, Jae-Hyun (Safety Convergence Center, Korea Conformity Laboratories)
Lee, Sang-Hoon (Safety Convergence Center, Korea Conformity Laboratories)
Publication Information
Journal of the Korean Recycled Construction Resources Institute / v.9, no.4, 2021 , pp. 492-498 More about this Journal
Abstract
In this paper, the electromagnetic wave transmittance of the reinforced concrete structure wall was analyzed using the performance measurement system of electromagnetic wave shielding. Recently, electromagnetic wave shielding technologies on the reinforced concrete wall conditions have been studied, and the shielding effectiveness have been tested on unit cell size. However, the unit cell size tests have problems on that the measurement range for shielding performance is insufficient and it is difficult to reflect the real conditions of the concrete wall. Therefore, we constructed a shielding performance measurement system using a large sample of 2.2m × 2.2m like a real wall. To verify the measurement system, general reinforced concrete test samples were selected, and real shielding performance measurements and numerical analysis were proceeded. Test and numerical analysis results showed similar tendencies in the evaluation frequency range of 75MHz to 2GHz. Thus we validated the effectiveness of this shielding performance measurement system.
Keywords
Concrete; Shielding concrete; Reinforced concrete; EMP shielding;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Choi, E.K., Yuan, T., Lee, J.Y., Yoon, Y.S. (2019). Self-sensing properties of concrete with electric arc furnace slag and steel fiber, Journal of the Korean Society of Hazard Mitigation, 19(1), 265-274 [in Korean].   DOI
2 Morari, C., Balan, I. (2015). Methods for determining shielding effectiveness of materials, Electrotechnica, eElectronica, Automatica, 63(2).
3 IEEE-STD-299 (2006). IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures.
4 Kim, B.H., Oh, J.H., Lee, S.H., Park, I.W., Oh, S.J. (2019). Analysis on the aperture size and transmission of electromagnetic wave for reinforced concrete wall shielding effectiveness measurement system, Journal of the Institute of Electronics and Information Engineers, 56(11), 92-98 [in Korean].   DOI
5 Ministry of Land, Infrastructure and Transport(MOLIT) (2016), Design Standard for concrete walls [in Korean].
6 Lee, N.K., Park, G.J., Park, J.J., Kim, S.W. (2019). A study on the electrical conductivity and electromagnetic shielding of high performance fiber reinforced cementitious composites(HPFRCC), Journal of the Korea Institute for Structural Maintenance and Inspection, 23(2), 37-43 [in Korean].
7 Hyun, S.Y., Lee, K.W., Kim, M.S., Yook, J.G. (2012). Electromagnetic modeling of shielding effectiveness of reinforced concrete walls, The Journal of Korean Institute of Electromagnetic Engineering and Science, 23(3), 384-391 [in Korean].   DOI
8 Jang, H.J., Song, T.S. (2018). Implementation of concrete block shielding effectiveness measurement system for RF shield, Journal of the Institute of Electronics and Information Engineers, 55(12), 85-91 [in Korean].   DOI
9 Jo, S.H., Cho, K.Y., Noh, Y.H., Lee, N.k., Kim, S.W., Yook, J.G. (2021). Electromagnetic shielding effectiveness of the concrete composite as a function of structural parameters of steel fibers, The Journal of Korean Institute of Electromagnetic Engineering and Science, 32(6), 517-526 [in Korean].   DOI
10 Ministry of Land, Infrastructure and Transport(MOLIT) (2018), Regulation for structure standards of building [in Korean].