• Title/Summary/Keyword: 구조성능시험

Search Result 1,589, Processing Time 0.027 seconds

Appraisal Study on Tensile Test Method of Mechanical Properties of FRP Composite Used in Strengthening RC Members (구조보강용 FRP 복합체의 역학적 특성치 분석을 위한 인장시험방법 평가 연구)

  • You, Young-Chan;Choi, Ki-Sun;Kang, In-Seok;Kim, Keung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • Experimental study has been performed in order to construct the standard test methods and appraisal criteria by investigating the influence of specimen types(property, width, layers) and loading rate on the tensile characteristics of FRP used in strengthening RC structures. The FRP composite tested in this study are the unidirectional CFRP sheet/strip and the bidirectional GFRP sheet. Test variables consist of the various width ranging from 10mm to 25mm and number of CFRP sheets plied up to 5 layers. Test results indicated that maximum tensile strength and minimum coefficient of variation are recorded at each different width according to the fiber types and weaving directions. Also, the average tensile strengths of CFRP sheets are decreased as the number of layer of CFRP sheet are increased.

A Study on the Characteristics of Bridge Bearings Behavior by Finite Element Analysis and Model Test (유한요소 해석과 모형실험을 통한 교량받침의 거동특성 연구)

  • Lee, Jae-Uk;Jung, Hie-Young;Oh, Ju;Park, Jin-Young;Kim, See-Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.96-106
    • /
    • 2014
  • The increased vibration level of the railway bridge could make significant noise and, also, cause structural damages such as fatigue cracks. Related to these subjects, a spherical elastomeric bridge bearing, which is layered by hemispherical rubber and steel plates, was investigated in terms of its vibration performance. Several different shape factors could be considered by changing the curvature of hemispherical surface and size in rubber and steel plate thicknesses in the manufacturing stage. The performance of the spherical elastomeric bearing for the reduction in vibration was compared with that of the conventional bearing by performing vibration experiments on a scale-downed model. The rubber material characteristics and spherical shape are found to be important parameters in reducing the bridge vibration.

Seismic Qualification of Class 1E Battery by Combined Analysis and Testing (수치해석과 실험을 통한 안전등급 축전지의 내진검증)

  • 김영중;박성환;정태영;정정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.87-91
    • /
    • 1992
  • 축전지를 탑재한 프레임형 랙에 대한 공진탐색시험결과를 이용하여 유한요 소에 의한 수치해석모형을 결정하였다. 내진검증시험은 에이징시험을 거친 3 개의 축전지를 포함하여 28개의 축전지를 탑재한 시험랙을 대상으로 수행되 었다. 공진탐색시험으로부터 구한 모달특성치를 이용하여 지진응답을 해석하 였으며 실험치와 부합함을 확인하였다. 시험랙의 지진응답이 실제 설치될 60 개의 축전지를 갖는 전체랙의 응답보다 크므로, 시험랙에 의한 내진검증이 보다 열악한 조건에서 수행되었다고 볼 수 있다. 시험랙에 대한 내진검증시 구조부재의 구조적 안정성과 축전지의 성능유지를 확인한 바 있으므로 전체 랙의 경우에도 내진검증이 이루어졌다고 판단된다.

  • PDF

Pullout and Flexural Performance of Structural Synthetic Fibers by Geometry and Sectional Area Change (구조용 합성섬유의 형상 및 단면적 변호에 따른 부착 및 휨 성능)

  • Won, Jong-Pil;Back, Chul-Woo;Park, Chan-Gi;Han, Il-Yeong;Kim, Bang-Lae
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.643-649
    • /
    • 2003
  • The purpose of this study were evaluated to flexural and bond performance by sectional area and geometry change through bond and flexural test of a structural synthetic fiber. Six deformed structural synthetic fibers were investigated and pullout and flexural test was conducted. Included parameters is three different geometries of fiber and two of fiber sectional area. The test result shows that the cycles and amplitude of structural synthetic fiber increased, pullout load and pullout fracture energy decreased and flexural strength increased, if sectional area is same. The sectional area increased, pullout load and pullout fracture energy increased and flexural strength decreased, if cycles and amplitude of structural synthetic fiber is same. Based on test results, structural performance of the concrete could know that is influence by pullout performance of fiber as well as various factor (fiber number, material properties etc).

Testing Procedures to Examine the Characteristics of LRBs (지진격리장치(LRB)의 특성검사방법)

  • 강형택;이민구;이창근;서주원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.401-408
    • /
    • 2002
  • 교량의 건설에 있어서 내진설계가 주요문제로 부각되면서, LRB(Lead Rubber Soaring)가 한 방법으로 사용되고 있다. 특히, 설계변경 또는 내진보수.보강과 같이 제약 조건이 있는 상황에서 유용한 면진방법으로 적용된 사례를 찾아 볼 수 있다. 이와 같이 LRB의 사용이 증가함에도 불구하고, 그 특성을 엄밀히 검증할 수 있는 시험기준이 정립되어 있지 않다. 따라서, 실무에서 LRB를 사용하는 경우 많은 혼란이 발생하고 있으며, 구조물의 면진성능에 대한 신뢰성도 떨어뜨리고 있다. 본 연구에서는 실무에서 발생하는 혼란과 LRB의 성능에 대한 불확실성을 줄이기 위하여 특성시험 기준을 정립하였다. 특성시험 기준은 미국 HITEC의 면진장치 특성시험 기준과 일본의 시험 기준을 토대로 국내 시방서와 시공 및 설계환경에 적합한 기준을 제시하고자 한다. 특성시험절차는 LRB의 연직강성, 수평유효강성, 감쇠비, 내구성 등 총 8개 항목에 대하여 정리하였다. 이 절차에 따라, 본 연구에서 실험이 수행 될 것이며, 시험 결과를 분석.평가한 후 세부사항을 재검토하여 실무에서 유용하게 사용할 수 있는 기준을 제시하고자 한다.

  • PDF

Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures (뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체 제안을 위한 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.7-15
    • /
    • 2016
  • The cross-sectional shape factor is used worldwide to evaluate the scientific performance of fire-resistant structures. In South Korea, however, a system for applying a cross-sectional shape factor has not been arranged and circular or rectangular steel pipes are commonly used for large-scale steel frame buildings. On the other hand, coating material-spray steel beams and pillars that have received the certification of a fire-resistant structure from recognized organizations are mostly limited to a H-beam. A H-beam is granted a wide range of certifications without size limitations from a non-loading performance test with test standards based on the relevant provisions. Other types of steel pipe are to be certified for fireresistance according to shape. In this study, a cross-sectional shape factor was used to propose standard testing specifications for the application of coating material-sprayed circular and rectangular steel pipes, eventually to set the scope of certification for reasonable fire-resistant structures.

A Durability Assessment on Complex Deterioration of Concrete with Ground Granulated Blast-Furnace Slag Replacement (복합열화 환경하에서의 고로슬래그미분말 사용 콘크리트의 내구성능 평가)

  • Lee, Seung-Hoon;Kim, Hyung-Doo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.171-175
    • /
    • 2010
  • This paper presents the experimental results of frost durability characteristics including freezing-thawing and de-icing salt scaling of the concrete for gutter of the road and marine structure. Mixtures were proportioned with the three level of water-binder ratio(W/B) and three binder compositions corresponding to Type I cement with 0%, 30% and 50% GGBS(Ground granulated blast furnace slag) replacement. Also, two different solutions of calcium chloride were used to evaluate their effect on the frost durability resistance. Specially, in case of complex of freezing and thawing with salt and carbonation, the deterioration of concrete surface is evaluated. Test results showed that the BFS30 and BFS50 mixture exhibited higher durability and lower mass loss values than those made with OPC mix and the use of GGBS can be used effectively in terms of economy and frost durability of the concrete to be in complex deterioration. Therefore, the resistance to complex deterioration with freezing-thawing was strongly influenced by the strength and the type of cement.

A Rigorous Examination of the Interplay Between Fire Resistance of 1-Hour Rated Fireproof Steel Walls and the Flexural Strength of Individual Panels (1시간 내화구조용 철강재 벽체의 내화성능과 단위 패널 휨강도의 관계 고찰)

  • Jeon, Soo-Min;Ok, Chi-Yeol;Kang, Sung-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.5
    • /
    • pp.537-546
    • /
    • 2023
  • For the purpose of fire delineation within buildings, steel walls in Korea are mandated to undergo rigorous certification as fire-resistant entities, substantiated via a series of qualitative assessments. Predominantly, these evaluations comprise the fire resistance test paired with supplementary examinations; specifically for steel walls, these encompass the gas hazard and panel bending strength tests. Given the prevalence of semi-noncombustible core materials, gas hazard tests are largely rendered superfluous, pivoting the focus solely onto the panel bending strength test during the certification trajectory. This particular test is designed to gauge the flexural robustness of individual wall panels. An enhanced bending strength is postulated to fortify both the structural integrity and thermal insulation of the wall by mitigating potential deformations. In this scholarly exploration, an analytical deep dive was undertaken into extant, valid certification test datasets. The endeavor aimed to ascertain the depth of correlation between the designated fire resistance metric and the bending strength, the latter being the sole supplementary assessment for steel walls. In distilling the findings, it was discerned that temperature elevations beyond baseline values exhibited no statistically salient linkage with the panel's bending strength.

Design and Integration of STM Propulsion System for LEO Observation Satellite Development (저궤도 관측위성용 구조 및 열 개발모델 추진시스템의 설계 및 제작)

  • Kim,Jeong-Su;Lee,Gyun-Ho;Han,Jo-Yeong;Jang,Gi-Won;Choe,Jin-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.8
    • /
    • pp.115-124
    • /
    • 2003
  • To guarantee the proper functions of a satellite in the extreme space environment, the several test models are developed generally. There are advantages that the design and the analysis of Flight Model(FM) can be validated through these test models, and the functional reliabilities can be increased by reflecting the modifications on the final design of FM. The integration and test of Structure & Thermal Model(STM) of KOMPSAT, being currently developed, have been completed. In this paper, the processes of design/analysis and integration of the STM propulsion system, one of the KOMPSAT modules, are described.