Browse > Article
http://dx.doi.org/10.11112/jksmi.2008.12.1.73

Appraisal Study on Tensile Test Method of Mechanical Properties of FRP Composite Used in Strengthening RC Members  

You, Young-Chan (한국건설기술연구소 건축구조.재료연구실)
Choi, Ki-Sun (한국건설기술연구소 건축구조.재료연구실)
Kang, In-Seok ((주)토탈인포메이션서비스 한국지점)
Kim, Keung-Hwan (한국건설기술연구소 건축구조.재료연구실)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.12, no.1, 2008 , pp. 73-80 More about this Journal
Abstract
Experimental study has been performed in order to construct the standard test methods and appraisal criteria by investigating the influence of specimen types(property, width, layers) and loading rate on the tensile characteristics of FRP used in strengthening RC structures. The FRP composite tested in this study are the unidirectional CFRP sheet/strip and the bidirectional GFRP sheet. Test variables consist of the various width ranging from 10mm to 25mm and number of CFRP sheets plied up to 5 layers. Test results indicated that maximum tensile strength and minimum coefficient of variation are recorded at each different width according to the fiber types and weaving directions. Also, the average tensile strengths of CFRP sheets are decreased as the number of layer of CFRP sheet are increased.
Keywords
FRP composite; Loading rate; Ply; Tensile property; Test method;
Citations & Related Records
연도 인용수 순위
  • Reference
1 KS M 3381, "유리섬유 강화 플라스틱의 인장 시험 방법", 한국산업규격, 2004. 7
2 유영찬, 최기선, 강인석, 김긍환, "FRP 복합체의 인장특성치 시험방법에 관한 변수 연구", 대한건축학회봄학술발표대회논문집, 제25권 1호, 2005, pp. 297-300
3 JIS K 7073, "炭素纖維强化プラスチックの引張試驗方法"
4 일본토목학회, "連續纖維しシートを用いたコンクリート構造物の補修補强指針", 2001
5 ISO 527-5:1997, "Plastics-Determination of tensile properties-Part 5: Test conditions for unidirectional fibre-reinforced plastic composites"
6 ASTM D 3039, "Standard test method for tensile properties of polymer matrix composite materials"
7 유영찬 외, "건축구조물 보수.보강 공법의 성능평가에 관한 연구", 한국건설기술연구원/건설교통부, 2001
8 EN 2561, "Aerospace series-Carbon fiber reinforced plastics-Unidirectional laminates-Tensile test parallel to the fiber direction"
9 ACI 440. 2R-02, "Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures", ACI Committee 440
10 유영찬 외, "시설물 보강공법 성능인증을 위한 시험항목.방법 및 평가기준 설정 연구," 건설교통부/한국건설교통기술평가원, 2006
11 CSA 806-02 Annex G, "Test method for tension test of flat specimens."