Abstract
Experimental study has been performed in order to construct the standard test methods and appraisal criteria by investigating the influence of specimen types(property, width, layers) and loading rate on the tensile characteristics of FRP used in strengthening RC structures. The FRP composite tested in this study are the unidirectional CFRP sheet/strip and the bidirectional GFRP sheet. Test variables consist of the various width ranging from 10mm to 25mm and number of CFRP sheets plied up to 5 layers. Test results indicated that maximum tensile strength and minimum coefficient of variation are recorded at each different width according to the fiber types and weaving directions. Also, the average tensile strengths of CFRP sheets are decreased as the number of layer of CFRP sheet are increased.
본 논문에서는 RC 구조물의 보수 보강 공사에 적용되는 FRP 복합체의 역학적 특성치를 평가하기 위하여 각국에서 제안된 시험규격을 비교 분석하고, 시험편 형상 및 시험방법의 차이가 재료성능에 미치는 영향에 대한 실험적 검증을 통하여 표준화된 시험방법 및 평가기준을 도출하고자 하였다. 주 실험변수는 FRP 복합체의 종류, 시험편의 폭, 보강매수 및 가력속도로 설정하였다. 본 시험결과에 의하면, 최대 인장강도와 최소변동계수를 나타내는 인장 시험편의 폭은 FRP의 종류/직조방법에 따라 다르게 나타났으며, 특히 적층형으로 시공되는 FRP 복합체는 보강매수에 따른 인장강도의 저하현상이 관측되므로, 이를 적절히 고려할 수 있는 평가기준의 설정이 필요할 것으로 판단된다.