• Title/Summary/Keyword: 구조벽체

Search Result 585, Processing Time 0.03 seconds

A Study On Structural Behavior of Anchor Pile Precast Retaining Wall with Screw Shape Flange (나선형 플렌지가 설치된 앵커파일 프리캐스트 옹벽의 구조적 거동에 관한 연구)

  • Choi, Seung-Seon;Ahn, Tae-Bong;Kim, Woo-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.129-138
    • /
    • 2013
  • In this study, Anchor Pile Precast Retaining Wall (APC) with screw shape flange was investigated and the results were arranged for designing APC specifications. Since precast materials require special care when they are manufactured, carried or treated, more accurate design and analysis of optimized dimension are needed : thus moment distribution of front foot was checked. Through full-scale field test, form and optimal stiffening shape were obtained and through fracture test with real load, applicable load was reasonably calculated. Research result in this thesis could be used as guideline or standard of designing and constructing Anchor Pile Precast Retaining Wall with screw shape flange.

The Optimization Algorithm for Wall Bracing Supports of Tower Cranes (타워크레인의 횡지지 최적설계 알고리즘 개발)

  • Lee, Hyun-Min;Ho, Jong-Kwan;Kim, Sun-Kuk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.1
    • /
    • pp.130-141
    • /
    • 2010
  • Poor expertise in equipment operation and installation, coupled with unpredictable natural disaster, usually directly leads to disastrous accidents of large lifting equipment such as tower cranes. For example, 52 tower cranes fell down due to the unstable support in Korea at the attack of Typhoon "Maemi" in 2003, which damaged property and caused loss of life. In high-rise construction projects, top-slewing or luffing-jib tower cranes needs checking the stability of lateral-support in addition to the bottom support such as the foundation. In this study, the optimization algorithm for lateral-support of tower cranes is conducted, which is expected to enhance the structural stability of tower cranes and save the cost in conflict with the safety.

A Study on the Performance Assessment of PHWR Containment Building (가압중수형 원전 격납건물의 성능평가에 관한 연구)

  • Lee, Hong-Pyo;Jang, Jung-Bum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.449-455
    • /
    • 2011
  • Recently, international collaborative research which was organized at Bhabha Atomic Research Centre in India, was conducted to develop for pressure capacity and nonlinear behavior of PHWR 1/4 scale nuclear containment building between experimental test and numerical code. In this paper, a nonlinear finite element analysis was carried out in order to predict ultimate pressure capacity and nonlinear behavior of the 1/4 scale containment building. The 1/4 scale containment building is consisted of basemat, cylinder wall, dome and 4-buttress. For the finite element analysis, commercial program ABAQUS was used. Finite element models including concrete, rebar and tendon have been developed for assessment of ultimate pressure capacity and failure mode for nuclear containment building. From the analysis results, first crack of the concrete, the yielding of the rebar and ultimate capacity pressure occurred at $1.6P_d$(design pressure), $3.36P_d$ and $4.0P_d$, respectively.

Analysis of Conjugated Heat Transfer for the Diffuser Exposed to Hot Combustion Gas (고온 연소가스에 노출되는 디퓨저의 복합 열전달량 계산)

  • Jin, Sang-Wook;Na, Jae-Jung;Rhe, Sang-Ho;Lee, Kyu-Jun;Lim, Jin-Shik;Kim, Sung-Don
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.231-234
    • /
    • 2010
  • Analysis of conjugated heat transfer has been conducted for the diffuser exposed to hot combustion gas to design the mechanical durability in high temperature. All the heat transfer means, conduction, convection and radiation have been considered to calculate the total heat flux from hot gas to diffuser surface. The calculation has been implemented by two kinds of methods. One thing is one dimensional method based on empirical equations. The other is CFD(Computational Fluid Dynamics) axisymmetric calculation containing ${\kappa}-{\omega}$ SST(Shear Stress Transport) turbulent model and DO(Discrete Ordinate) radiation model. The derived results of two methods have compared and showed similar values. From this result, the amount of cooling water and the dimension of water cooling channel were decided.

  • PDF

New Building Materials and Methods for Modernized Korean Housing (Hanok) (보급형 신한옥을 위한 부위별 공법 개발 및 영향도 분석)

  • Kim, Min;Kim, Hyosun;Ryu, Jaeseon;Jung, Youngsoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.2
    • /
    • pp.23-32
    • /
    • 2014
  • Modernized Korean housing (Hanok) with competitive price has been actively developed due to the increased interests in traditional Korean housing. Developing new building materials and methods is an essential area for Modernized Hanok. This paper compared and analyzed two mock-up buildings of Modernized Hanok and one mock-up of Traditional Hanok those were actually constructed as test-beds. Many different new methods were introduced, and their influences on construction cost and schedule were analyzed in order to verify the research results as well as to find implications for future direction. As a result, the construction cost and schedule of Modernized Hanok have been decreased by about 40% and 20%, respectively, when compared with traditional one. 'Wood frame' and 'Roof' are found as being the most influencing areas with highest weights in terms of cost and schedule. Therefore, further development in these two areas would facilitate to reduce overall cost of Modernized Hanok with improved building performance.

Invention Methodology of High Strength Insulated Steel Stud using TRIZ (강도향상형 단열스터드 개발을 위한 트리즈 기법 활용방안)

  • Cho, Bong-Ho;Kim, Sun-Sook;Kwak, Chai-Eun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.3
    • /
    • pp.33-41
    • /
    • 2013
  • This study used TRIZ methodology to develop a new steel stud for load bearing or non-load bearing walls. Technical contradiction of high strength with high insulation performance can be solved by TRIZ. We suppose a new shape of high-strength insulated (HSI) Stud. This study showed TRIZ can be usefully applied to the development of new construction materials by solving technical contradictions. Insulation performance of HSI stud can be improved approximately 12% compared to the standard KS stud. Although up to 3.9% of the flexural strength degradation is expected, compressive strength of HSI studs are improved from 4.1% to 8%. In conclusion, improved thermal performance and higher strength can be expected for the HSI stud developed using TRIZ.

Stability evaluation of reinforced earth walls based on large-scale modular blocks (대형 축조블록을 이용한 보강토옹벽의 안정성 평가)

  • Han, Jung-Geun;Kim, Min-Woo;Hong, Kikwon;Yun, Jung-Mann
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.143-151
    • /
    • 2014
  • This paper describes external and internal stability of reinforced earth wall using large-scale modular block and geogrid reinforcement. The evaluation for external and internal stability was conducted to analyze effect of wall height, reinforced soil (or backfill soils) and reinforcement strength. The external stability showed that the analysis cases were satisfied with design criteria, when the required minimum length and vertical spacing of reinforcement were 0.7H and 1m, respectively. The internal stability conformed that some cases were satisfied with design criteria in $25^{\circ}$ of internal friction angle of reinforced soil. Expecially, it will be applicable as wall structure considering a structural stability and economic efficiency based on evaluation of internal stability.

A Study on Reinforcement Method of Reinforced Soil Retaining Wall Through Field Experiment (보강토옹벽의 배부름현상 분석 및 보강 방법에 대한 실험적 연구)

  • Lee, Won-Hong;Mun, Byeong-Jo;Lee, Seuong-Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.103-112
    • /
    • 2019
  • This study proposes a system to control the bulging phenomenon occurring in the reinforced earth retaining wall and to evaluate the reliability of the system by field experiment. In this study, drainage facilities were not installed in order to induce reinforcement earth retaining wall bulging, and the bulging was induced by rainfall. The induced bulging displacement exceeded the horizontal displacement criterion during the construction of FHWA. The retaining wall block was drilled and grouting was performed by inserting the nail into the drilling hole. The wire mesh is installed on the reinforcing surface and the head of the nail is connected horizontally so that the blocks of the reinforcing earth retaining wall can be supported with each other. In order to protect the reinforcements, the reinforcement surface was closed with shotcrete and a measuring device was installed to detect the progress of the displacement. After the reinforcement, the bulging were not found to progress any more, confirming the reliability of the system.

Insulation Effect of Double Layered Bubble Sheet Application in Cold Weather Concrete and Initial Quality Control by Wireless Sensor Network (한중시공에서 2중 버블시트 포설에 따른 단열 효과분석 및 무선센서 네트워크에 의한 초기 품질관리)

  • Han, Min-Cheol;Seo, Hang-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2021
  • The objective of this study is to evaluate the effect of the application of double layered bubble sheet on the curing of slab and wall concrete placed at the job site in cold weather and to offer a feasibility of Concrete IoT Management System(CIMS), which is wireless sensor network developed by the authors, to manage early age quality of the concrete in terms of temperature, maturity and strength development. Test results indicated that the application of bubble sheet enhances the insulation performance, which results in an increase of the temperature by around 1~20. 6℃. It is found that CIMS can gather the temperature, maturity and strength development data from the sensors embedded from 30 m far from CIMS successfully. Predicted compressive strengths by CIMS had good agreement with measured ones within 2 MPa error level until 7 days. It is thought that the combination of the bubble sheet application for cold weather protection and CIMS for quality management tool in cold weather concreting contributes to shorten the time for the form removal by one day.

Stiffness Degradation Induced by Seismic Loading on a RC Shear Wall (지진하중에 의한 철근콘크리트 전단벽의 강성 저하에 관한 연구)

  • Lee, Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.48-54
    • /
    • 2022
  • This research describes a quantitative procedure used to estimate the effect of concrete cracking on stiffness degradation of concrete shear walls and provides analytical references for the seismic design of concrete shear walls. As preliminary research on the seismic response of concrete shear walls, nonlinear transient analysis was performed with commercial FE software. The study presents the nonlinear time history analysis results in terms of concrete damage and cracking behavior induced by seismic input motions. By varying the input motions, concrete strength and shear wall thickness, the seismic responses of a shear wall were examined with nonlinear time history analysis, and the progressive cracking behavior and corresponding hysteresis loop were described. Based on the analysis results, frequency and stiffness degradation of the shear wall from progressive concrete damage and cracking were captured with respect to the seismic levels. The results of this study suggest that stiffness degradation from concrete cracking should be appropriately considered when determining the seismic capacity of RC shear wall structures.