Analysis of Conjugated Heat Transfer for the Diffuser Exposed to Hot Combustion Gas

고온 연소가스에 노출되는 디퓨저의 복합 열전달량 계산

  • Published : 2010.11.25

Abstract

Analysis of conjugated heat transfer has been conducted for the diffuser exposed to hot combustion gas to design the mechanical durability in high temperature. All the heat transfer means, conduction, convection and radiation have been considered to calculate the total heat flux from hot gas to diffuser surface. The calculation has been implemented by two kinds of methods. One thing is one dimensional method based on empirical equations. The other is CFD(Computational Fluid Dynamics) axisymmetric calculation containing ${\kappa}-{\omega}$ SST(Shear Stress Transport) turbulent model and DO(Discrete Ordinate) radiation model. The derived results of two methods have compared and showed similar values. From this result, the amount of cooling water and the dimension of water cooling channel were decided.

고온의 연소가스에 노출되는 디퓨저 냉각에 필요한 열량을 계산하였다. 디퓨저 내부는 공기와 혼합된 연소가스가 흐르고 디퓨저 벽체는 채널로 구성된 공간에 물이 흐르도록 되어 있다. 디퓨저 구조물과 유체 간에 또는 유체 자체적인 열전달과 구조물 내부의 열전달 현상은 복합적인 형태로 나타나는데 고온에서 작동하는 점을 고려하여 복사, 대류, 전도 모두를 적용 하였다. 열전달량 계산은 경험식에 근거한 1차원 해석과 CFD 해석의 2가지 방법으로 수행하였다. 1차원 해석은 경험식을 통해 얻어진 결과를 적용하여 열전달량을 산출하였고, CFD 해석은 DO 복사 열전달 모델을 적용하여 계산하였으며, 계산의 타당성을 검정하기 위하여 두 방법을 비교하였다. 총 열전달량의 차이는 1% 미만으로 거의 같았으나, 1차원 계산은 열전달 모델의 단순화로 디퓨저 입구에서의 순환영역을 구현하지 못하여 전체적인 열전달량 분포에서는 차이를 보였다. 디퓨저의 안정성을 확보하기 위한 냉각수 용량은 2가지 계산 결과를 조합하여 각 구간별로 최대 열전달량을 근거로 도출하였다.

Keywords