• Title/Summary/Keyword: 구조검토

Search Result 5,953, Processing Time 0.043 seconds

Time Domain Modal Identification Method by using Measured Signals and its Sensitivity to Measurement Noise (측정치를 이용한 시간영역 모우드 특성 규명 기법 및 잡음에 대한 민감도 분석)

  • Choi, Hyung Jin;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.1 s.44
    • /
    • pp.83-91
    • /
    • 2000
  • The first Procedure to identify structural system by using measured data is transformation of data to frequency domain and try to recognize modal characteristics in graphical condition. Those methods are doubted about the reliability to the civil structures, especially bridges which has coupled and close modal characteristics. In this paper, feasibility of time domain modal Identification methods were examined and applied double least square method to overcome bias characteristics of the identification methods. To show the advantage of proposed method, simulation were carried out for mass-spring model. And to examine the usage of the method in realistic case, sensitivity of the methods to noise was performed.

  • PDF

An Analytical Study on Flexural Behaviors of CFT Girder (CFT 거더의 휨 거동 평가를 위한 해석적 연구)

  • Ko, Hee Jung;Moon, Jiho;Lee, Hak Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.35-35
    • /
    • 2011
  • CFT가 갖는 다양한 구조적 이점으로 인해, 축력이 지배적인 기둥 구조물에만 주로 적용되던 CFT 요소가 점차 거더에 적용되어 가고 있다. 그러나, 현재 CFT 요소에 대한 설계 기준은 축력이 지배적인 보-기둥 구조물에 대한 것으로 제한되어 있으며, 휨이 지배적인 보 구조물에 대한 현행 설계 기준의 적용성을 검토해야 할 필요가 있다. 현행 설계기준에서 제시하고 있는 CFT 요소의 극한 강도 평가방법은 소성응력분배법 및 변형률적합법으로 구분되어지며, 각 방법을 이용한 극한 강도의 평가결과를 기존 연구자들의 CFT 요소 휨 실험결과와 비교 분석하였다. 휨 강성 평가에 대한 타당성을 검증하기 위해 AISC에서 제시하는 휨 강성 평가식을 기존 실험 연구와 비교 검토하였으며, 아울러 압축력에 따라 휨 강성을 보정할 수 있도록 수정된 Roeder et al.의 제안식을 함께 검토하였다. 검토 결과, 강도 평가에 있어서는 설계 기준에서 제안하는 두 방법 모두 CFT 거더의 휨 강도를 적절히 평가할 수 있었으며, 강성 평가에 있어서는 설계 기준의 제안식이 휨 초기 강성을 적절히 평가하는 반면 사용 단계에서의 휨 강성은 Roeder et al.의 수정된 강성 평가식에 의해 적절히 평가할 수 있음을 확인하였다.

  • PDF

A Comparison between Measurement Values and Prediction Values of Structure-borne noise induced by Subway (지하철 진동에 의한 구조음 실측치와 예측치 비교)

  • Lee, Tae-Ho;Ann, Yong-Chan;Cho, Jung-Sik;Lee, Ki-Ryung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.817-820
    • /
    • 2014
  • 지하철 인근 지역에서 차량 통과 시 차륜과 레일의 상호작용으로 인한 진동이 지반을 통하여 건물까지 전파되어 구조전달음이 발생하게 된다. 이러한 구조전달음이 발생하는 지하철 인근 지역에서 도로나 주거단지가 새롭게 조성될 예정인 경우, 완공 이후에 발생하는 구조전달음 영향을 사전에 평가하고 대책을 수립하는 것이 요구된다. 본 논문에서는 국내에 위치한 일부 역사에서의 구조전달음을 측정하고 국외의 예측식을 검토하여 구조전달음의 실측치와 예측치를 비교한다. 따라서 국내 지하철의 구조전달음 예측에 대하여 국외 예측식의 타당성을 검토함으로써 향후 건설될 지하구간 역사의 인근 주거지역에 대한 구조전달음을 예측하는데 기초 자료로 활용하고자 한다.

  • PDF

Evaluation of Creep Models with the Consideration of Concrete's Strength Level (콘크리트 강도대별 크리프 예측모델 평가)

  • Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.154-159
    • /
    • 2010
  • Recent concrete structures have been being constructed with higher strength concrete than normal strength concrete. Therefore, it is necessary to review the applicabilities of current design codes and models for the prediction of mechanical behaviors of concrete materials such as creep. To investigate the applicability of creep model with the consideration of the strength level of concrete, three current models (ACI 209R, CEB-FIP MC90 and EC2) were studied and compared with series of experimental results. It was shown that EC2 model which is the updated model of CEB-FIP MC90 better predicts creep coefficient for high strength level concretes and showed relatively good agreements with experimental data.

A study on ventilation capacity and water catchment facilities of a cable tunnel (전력구 환기용량 및 집수설비 규격검토)

  • Song, Choong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2066-2067
    • /
    • 2007
  • 지중송전선로는 2006년 기준으로 전체 송전선로의 8.8%를 차지하고 있으며 그 점유비율은 점차 증가하는 추세이다. 지중송전선로의 주요 구조물 중 하나인 전력구는 "토목구조물 시공 -부대설비 시설 - 케이블 포설"의 순서로 공정이 진행된다. 전력구 부대설비 중 환기설비, 배수시설에 대한 검토는 토목 구조물의 기초설계시에 설치위치와 더불어 그 규격에 대한 검토가 이루어져여 하나 관련 기준이 명확하지 않아 정확한 검토에 어려움이 따른다. 본 논문에서는 최근 개정된 한전 설계기준 및 제정된 전력구부대설 비시설기준을 토대로 집수정의 규격에 대한 검토기준을 제시하였고 아울러 환기설비에 대한 설계방법을 구체적으로 제시하였다.

  • PDF

NON-MASS DETONATOR에 대하여 (대량 비순폭뇌관)

  • 손경복;박종석;김술환
    • Explosives and Blasting
    • /
    • v.9 no.2
    • /
    • pp.31-36
    • /
    • 1991
  • 뇌관의 수송, 최급중 안전성을 향상시키기 위하여 대량 순폭을 방지하는 방법으로 첫째 뇌관을 구조적으로 NON-MASS DETONATOR화 하는 방법과 둘째 포장법을 개선하여 NON-MASS DETONATON이 되지 않는 방법을 검토하였다. NON-MASS DETONATOR로 구조변경은 제조 설비확보, 화약종류를 바꾸는 등 문제점이 있어 당장 시행이 곤란하고 포장방법 개선은 포장원가 상승 요인은 있으나 현재 국내 시판되는 뇌관의 구조변경 없이 NON-MASS가 가능하므로 적극적으로 검토할 필요가 있을것으로 판단된다.

  • PDF

Strength Analysis of the High Performance Nozzle System(Jet Vane Type) (Jet Vane Type 추력방향제어 시스템 구조 해석)

  • 조용재
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.23-23
    • /
    • 1998
  • Jet Vane Type 추력방향제어 시스템의 구조적 안정성을 검토하기 위해 시스템의 해석을 Vane, Ablation & Bracket Interface, Nozzle flange & Housing Interface 및 Fastener의 세 부분으로 나누어 수행하였다. 해석을 위한 외력조건은 유동해석을 통해 얻어진 온도 및 압력분포에 근거하였으며, Vane의 응력해석을 위해서는 상용 Software인 Patran 및 Nastran이 사용되었다. 이번 연구는 Test Model 단계로서 충분한 강도의 고정 Housing이 사용되어, 이에 대한 해석은 수행되지 않았지만 추후 Flight Model 단계에서는 함께 고려되어질 것이며, 각 경우의 Margin of Safety값들을 도출하여 구조적 안정성을 검토하였다.

  • PDF

A Study on the Optimun Shape of Rope Brake Device (로프 브레이크의 최적형상에 관한 연구)

  • Lee Jong-Sun;Kim Jung-Hoon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.59-62
    • /
    • 2004
  • 본 논문은 엘리베이터의 미끄럼이나 과속을 방지할 수 있는 보조 제동장치인 로프 브레이크에 관한 것으로 제동시 반력의 최대 영역 즉, 취약 부분(weak point)으로 예상되어지는 하우징 영역의 보강형상을 위치와 높이를 변화시켜서 구조해석을 수행하여 최대응력과 최대변형률을 비교 분석하여 하우징의 안전성을 검토한 후, 최적형상의 하우징을 적용시킨 로프 브레이크의 설치 각도에 따른 구조해석을 수행하여 구조적 타당성을 검토하고자 한다.

  • PDF

A Study on the Prevention of Collapse Disaster in a Form (거푸집 동바리 붕괴재해 예방대책 에 의한 연구)

  • Ham, Eun-Gu;Heo, Dai-Seong
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.161-162
    • /
    • 2023
  • 본 연구는 거푸집 동바리 붕괴재해 예방대책 마련하기 위해 실시되었으며 구조검토, 재료문제, 설치문제, 작업방법 불량 등으로 기존의 가설작업이 서류적으로 형식상의 안전점검 및 구조검토서를 반영한 현장관리로 재해발생이 빈번하게 이루어지고 있는점을 착안해 현장대응 방법을 변경하여 관리하는데 목적을 둔다.

  • PDF