• Title/Summary/Keyword: 구면

Search Result 473, Processing Time 0.028 seconds

Enhanced Dual Contouring method by using the Feature of Spherical Coordinate System (구면 좌표계의 특성을 이용한 듀얼 컨투어링 기법 개선)

  • Kim, Jong-Hyun;Park, Tae-Jung;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.2
    • /
    • pp.27-36
    • /
    • 2011
  • The Dual Contouring method has an advantage over the primal polygonization methods like the Marching Cube method in terms of better expression of sharp features. In this paper, the Dual Contouring method is implemented in Spherical coordinates, not the Cartesian ones to examine some characteristics. For this purpose, our octree is defined in Spherical coordinates, which is called "S-Octree". Among some characteristics, the proposed Dual Contouring method in the S-Octree tends to produce less vertices at the same octree level. In particular, for any surface models close to surface sphere, the generated mesh surfaces are smoother and more detailed than those of the Cartesian Dual Contouring approach for specific applications including mesh compression where available geometric information is quite limited.

Comparison of preference and Empirical Fit Success Rates for Spheric and Aspheric RGP Lenses (구면 및 비구면 디자인 RGP 콘택트렌즈의 선호도와 경험적 피팅 성공률 비교)

  • Kim, Jai-Min;Kim, Soo-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.9-16
    • /
    • 2008
  • To assess the preference and efficacy of empirical fitting methods with spheric and aspheric RGP lenses. Methods: Healthy 37 subjects were fitted with spheric design (diameter 9.3 mm) on right eye and aspheric design (dia 9.6 mm) on the left eye. Base curves which were fitted empirically (using on-K, Kavg-0.50D (or 1.00D) and manufacturer's recommended fitting guide) were compared with another base curve which obtained the best diagnostic fit with spheric and aspheric RGP lenses. The preference and fitting type (lid attachment or interpalpebral) for two design lenses were investigated 2 weeks after fitting RGP lenses. Results: Of 33 successful RGP lens-wearing subjects, 76% preferred spheric design compared with 24% of aspheric RGP lens wearers. Sixty seven percent were fitted with lid-attachment in spheric lenses, whereas 64% were fitted with lid-attachment in aspheric lenses. The acceptable fit success rates within ${\pm}$0.50D of base curves were 97% for the on-K fit, 100% for the Kavg-0.50D fit and 100% of the manufacturer's guide fit compared with the diagnostic fit in spheric design, whereas 91%, 79% and 94% reported on-K, Kavg-1.00D and manufacturer's guide, respectively, in aspheric design. Conclusions: Although aspheric RGP lenses are more popular in the Korean market, it is still preferable to fit subjects with spheric RGP lenses. Empirical fitting may be best accomplished with the spheric lenses using Kavg-0.50D fit and the manufacturer's fitting guide, whereas aspheric RGP lens designs are unacceptable lens fit based on empirical fitting.

  • PDF

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

The Effects of Spherical and Aspherical RGP Contact Lenses on Visual Performance (구면 및 비구면 RGP 콘텍트렌즈가 시력의 질에 미치는 영향)

  • Kim, Soo-Hyun;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2009
  • Purpose: This study was to evaluate corneal topography, contrast sensitivity and ocular response of a RGP, back surface aspherical contact lens compared with a spherical contact lens. Methods: A total 37 subjects were fitted with a spherical lens in right eye and an aspherical in the left eye and were evaluated for changes in corneal topography and contrast sensitivity over a 2-month period. Results: Thirty-four of 37 subjects completed the 2-month study. The corneal topography did not show differences between spherical and aspherical RGP lenses. The eyes fitted with the aspherical lenses demonstrated a greater reduction in contrast sensitivity compared with their spherical counterparts under photopic condition. Subjects preferred comfort and ocular responses provided by the spherical lens. Conclusions: Corneal topography when comparing spherical and back surface aspherical RGP lenses did not show any significant difference in the subjects. Spherical RGP lens yields better contrast sensitivity and preference than aspherical RGP lens at photopic condition. Further investigation of aberrations induced by contact lens design is warranted to explain the observed differences in visual performance.

  • PDF

Extension for Downward Continuation of the Method of "Upward Continuation of Potential Field on Spherical Patch Area" ("구면부분지역에서 퍼텐셜마당의 상향연속"의 하향연속 확장적용)

  • Na, Sung-Ho;Chung, Tae Woong;Shin, Young Hong
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.1
    • /
    • pp.59-62
    • /
    • 2013
  • We formerly reported a new method for the upward continuation of potential field on spherical patch area including Earth's curvature, which has been neglected in most studies on rectangular area with flat Earth assumption. This new method is applicable to downward continuation as well by only assigning corresponding value for the ratio of two radii; $r_2/r_1$, i.e., target radius $r_2$ versus datum radius $r_1$. In addition, the inherent problem of this method due to spherical surface geometry is described, and its one possible remedy is given.

Deep Learning Based Object Recognition in Spherical Panoramic Image (구면 파노라마 영상에서의 딥러닝 기반 객체 인식)

  • Jung, Minsuk;Park, Jong-Seung
    • Journal of Korea Game Society
    • /
    • v.18 no.5
    • /
    • pp.5-14
    • /
    • 2018
  • A lot of research has been done on image recognition technique for planar images and the performance has also been improved. However, it is difficult to recognize objects in spherical panoramic images or images in special form which are given in various environments because of the spherical distortion given in different form from the planar case. In this paper, we show that the neural network recognition approach can be used for object recognition in spherical image and suggest a method of using cubemap transform in order to increase recognition accuracy in spherical image.

Real Coded Genetic Algorithm On n-Dimensional Sphere (n차원 구면상에서의 실수 코딩 유전 알고리즘)

  • Kim, Jin-Hyun;Moon, Byung-Ro
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06a
    • /
    • pp.125-129
    • /
    • 2010
  • 본 연구에서는 실수 코딩을 사용하는 유전 알고리즘의 문제공간이 n차원 구면으로 제한된 경우에 사용 할 교배 연산자와 변이 연산자를 제안하고, 이를 실제로 사용한 실험 결과를 제시한다. n차원 실수 공간에서 일반적으로 사용되는 연산자를 n차원 구면에 사영하는 방법을 사용하였으며, 해의 범위가 제한된 경우에 사용할 해의 수선 방법도 제안하였다. 제안된 연산자를 사용하며 몇 가지 최적화 문제를 푸는 실험을 한 결과 평균 오차율 2.0%내에서 최적해를 구함을 확인하였다.

  • PDF

Liquid Crystal Lens for the Compensation of Spherical Aberration

  • 정석호;최성욱;왕지석;김영주
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.151-152
    • /
    • 2005
  • Blu-ray 디스크에서는 NA=0.85 의 높은 개구수를 채용함으로써 디스크 보호층의 두께 변동에 따른 구면수차 발생량이 매우 커지는 문제가 발생하게 된다. 따라서 디스크 두께 공차 $3{\mu}m$에서 Blu-ray 시스템의 수차 발생 허용수준을 초과한다. 그리고 Multi-layer 디스크의 경우 각 층의 간격이 $25{\mu}m$ 정도의 간격을 두고 배치되어 있어 기록층 사이에서 발생하는 구면수차의 보정이 필요하며, 종래의 기술은 보상범위가 $3{\mu}m$로 한정되어 사용이 불가능하며 또한 대물렌즈 조립공차가 엄격히 관리되어야 하는 문제점을 안고 있었다. 본 연구에서는 액정렌즈에 의한 구면수차 보정으로 이러한 문제점들을 해결하고자 하였다. 액정렌즈는 오목렌즈 액정소자와 볼록렌즈 액정소자로 구성되며 픽업 광학계 내에 조합하여 설계함으로써 Multi-layer 디스크의 두께 변동에 따라 발생하는 구면수차를 보정하고 대물렌즈 조립공차 문제를 해결할 수 있다.

  • PDF

Design and Aberration Analysis of Four-Spherical Mirror System Corrected for 4 Aberrations (4개의 수차가 보정된 유한 물체점을 갖는 4-구면 반사경계의 설계 및 수차해석)

  • 김종태;공홍진;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.127-132
    • /
    • 1991
  • We have obtained the analytic solutions of the four spherical mirror system free from the Seidel third order aberratios which are spherical aberration, coma, astigmatism, and distortion, Vignetting. Petzval field curvature, and optical properties according to the design parameters are numerically investigated and optimized. The numerical aperture of this system is 0.2 and the half field angle is $1.5^{\circ}$.

  • PDF

Four Spherical Mirror Stepper Optics for Deep UV Micro-Lithography (Deep UV 마이크로 리소그라피용 Stepper를 위한 4구면 반사경계)

  • 조영민;이상수;박성찬
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.186-192
    • /
    • 1991
  • For the micro-lithography using a excimer laser beam $(\lambda\leq0.248$\mu\textrm{m})$. a mirror system consisting of four spherical surfaces with reductlon magnification 5X is designed. Initially the aplanat, flat field and the distortion free condition of the system are analytically investigated within Seidel 3rd order aberrations. And the computer-aided optimization technique has been employed for the further improved performance of the system. The final system has N.A. of 0.15 and image field diameter 3.3 mm, and has the diffraction-limited performance for KrF eximer laser beam.

  • PDF