Influences to Additive Type on Carbon Nanotube metal composite (첨가제 종류에 따른 탄소나노튜브 금속복합재료 소결코팅 영향)

  • Kim, Dea-Hea;Zheng, XI-Ru;Kim, Myin-Su;Park, Chan-Woo
    • Composites Research
    • /
    • v.25 no.5
    • /
    • pp.159-163
    • /
    • 2012
  • The coating of metal surface with carbon nanotubes(CNTs) has been studied for the heat transfer enhancement of the boiling and condensation of refrigerant. The multiwalled carbon nanotube/copper oxide(CuO) composite powder, which has been surface modified by dispersant and polyvinyl alcohol solution, was ultrasonically sprayed and sintered on a copper wafer. In this paper, experiments were performed to assess the characterization and comparison of the carbon nanotube before and after sinterning and the morphology changes of the CNT/CuO-coated surface by using different dispersants. The dispersants used are THF (Tetrahydrofuran), SDBS(Dodecylbenzenesulfonic acid sodium salt), SDS(Sodium dodecy sulfate). The samples were examined by scanning electron microscopy(SEM), thermogravimetric analysis(TGA), differential scanning calorimeter(DSC) and Raman spectroscopy.

A Study on the Leachate Characteristics of Heavy Metals from MSW Bottom Ash Solidified with Stabilizing Reagents (안정화제를 첨가한 생활폐기물 소각시설 바닥재의 중금속 용출특성에 관한 연구)

  • Lim, Jong-Wan;Dong, Jong-In
    • Applied Chemistry for Engineering
    • /
    • v.26 no.6
    • /
    • pp.692-697
    • /
    • 2015
  • In this study, the reduction efficiencies of leachate heavy metal levels were investigated by adding $Al_2O_3$ and CaO to the bottom ash to observe their effects on the heavy metals leachate reduction efficiency. The ratio of $Al_2O_3$ and CaO contents were varied by 10~40% (W/W) alongside different curing time of 7 and 28 days. The reduction efficiencies of leachate heavy metal levels were estimated to be 69.3% for Cu and 52.1% for Pb during the curing time of 7 days. For the curing time of 28 days, the efficiencies changed to 85.2 and 100% for Cu and Pb, respectively. It was thus confirmed that the high reduction efficiency could be obtained as the curing time increased.

A study on change in electric contact resistance of the tin-plated copper connector of automotive sensor due micro-vibration (차량용 주석 도금된 구리 커넥터에서 미세진동에 의한 전기접촉 저항변화에 관한 연구)

  • Yu, Hwan-Sin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.653-658
    • /
    • 2008
  • The automotive environment is particularly demanding on connector performance, and is characterized by large temperature changes, high humidity and corrosive atmospheres. Fretting is a contact damage process that occurs between two contact surfaces. Fretting corrosion refers to corrosion damage at the asperities of contact surfaces. This damage is induced under load and in the presence of repeated relative surface motion, as induced for example by vibration. This paper critically reviews the works published previously on fretting corrosion of electrical connectors. Various experimental approaches such as testing machines, material selection, testing environments, acceleration testing techniques and preventing methods are addressed. Future research prospects arc suggested.

  • PDF

A Study on the Removal of Silver in Copper Electrolyte (황산동전해액(黃酸銅電解液) 중 은(銀(Ag)) 제거(除去)를 위한 연구(硏究))

  • So, Sun-Seob;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.17 no.5
    • /
    • pp.60-65
    • /
    • 2008
  • A study on the removal of silver(Ag) in copper electrolyte was carried out to produce high purity copper by using various method such as ion exchange resin, activated carbon adsorption, copper cementation with powder and wire, CuS precipitation. Parameters, such as reaction time, reaction temperature, addition amount etc. were investigated to determine the effective condition of silver removal. CuS precipitation and ion exchange using Lewatit TP214 was found to be effective. Especially, silver content in copper electrolyte was reduced from 10 ppm to less than 0.1 ppm by ion exchange with Lewatit TP214.

Effect of Additives on the Hardness of Copper Electrodeposits in Acidic Sulfate Electrolyte (황산구리 전착에서의 첨가제가 구리전착층의 경도에 미치는 영향)

  • Min, Sung-Ki;Lee, Jeong-Ja;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.143-150
    • /
    • 2011
  • Copper electroplating has been applied to various fields such as decorative plating and through-hole plating. Technical realization of high strength copper preplating for wear-resistant tools and molds in addition to these applications is the aim of this work. Brighters and levelers, such as MPSA, Gelatin, Thiourea, PEG and JGB, were added in copper sulfate electrolyte, and the effects of these organic additives on the hardness were evaluated. All additives in this work were effective in increasing the hardness of copper electrodeposits. Thiourea increased the hardness up to 350 VHN, and was the most effective accelarator in sulfate electrolyte. It was shown from the X-ray diffraction analysis that preferred orientation changed from (200) to (111) with increasing concentration of organic additives. Crystallite size decreased with increasing concentration of additive. Hardness was increased with decreasing crystallite size, and this result is consistent with Hall-Petch relationship, and it was apparent that the hardening of copper electrodeposits results from the grain refining effect.

A Study on the Electroless Ni-Cu-P Alloy Plating of Al Base Hard Disk(I)Effect on some Properties of Electroless Ni-Cu-P Deposits by Electrolyte and Heat Treatment Condition (알루미늄 기판의 무전해 니켈-구리-인 합금도금에 관한 연구(I) 전해액 및 열처리 조건이 무전해 니켈-구리-인 도금층의 제 물성에 미치는 영향)

  • 오이식;황용길
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.2
    • /
    • pp.103-113
    • /
    • 1991
  • Electroless Ni-Cu-P alloy plating of Al base hard disk was performed to investigate some properties according to the change of composition. It was found that the composition of Ni and Cu in deposits changed linearly with increasing the mole ratio of NiSO4.6H2O/CuSO4.5H2O. The increase in hardness by heat - treatment was confirmed to be associated with small size grained crystallization of the amorphous deposits. Acid resistance of all deposits layer. which had been heated up to 30$0^{\circ}C$, was found to be exellent when immersed in 1N-H2SO4 solution, and it showed more superior acid resistance with decreasing Cu content and with increasing P. The resistivity of the deposits heat treated became smaller at temperature more than 50$0^{\circ}C$, and it became largerly with increasing P content. Cu 44.1wt% alloy(C bath) showed the most superior non-magnetically stable characteristics after heat treatment. It was superiorly with higher temperature and with decreasing P content.

  • PDF

Rate Augmentation of Exothermic Hydration in the CaO Packed Bed (CaO 충전층의 수화발열반응 촉진)

  • Chung, Soo-Yull;Kim, Jong-Shik
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.91-101
    • /
    • 1994
  • Heat release characteristics of a CaO packed bed reactor which is used for a chemical heat storage device has been studied. We employed Cu-plate fins to release the heat of reaction of the CaO packed bed inside the reactor fast and effectively. Two-dimensional analysis of unsteady state heat flow inside the bed was performed as a function of time and under various conditions of the Cu-plates. It is noted that the time required to release the heat of reaction with Cu fins is reduced more than twice fast compared to that without Cu fins. That was largely dependent upon the number of Cu-plate, as well.

  • PDF

소음과 난청

  • 장선오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.7-17
    • /
    • 1994
  • 소음이 청기에 미치는 영향에 대해서는 서기 1세기 경부터 그 기록을 더듬을 수 있다. 1713년 Ramazini는 구리 세공자에게 소음을 방지하기 위한 귀 보호기 사용을 권하였으며, 이후 18세기 중엽 산업 혁명을 거쳐 1,2차 세계대전과 함께 20세기의 폭발적인 산업 발달에 맞추어 소음은 문명의 필연적 산물이 되면서 이에 대한 관심이 높아졌다. 우리나라도 경제 발전과 동시에 공장 소음, 자동차 소음등이 날로 심각해지면서 이에 대한 연구가 활발해지고 있으나, 국내외 모두 소음성난청의 치료 면에서는 뚜렷한 방법을 제시하지 못하고 있는 실정이다. 소음에 의한 난청은 일단 한번 발생하면 형태 및 기능이 불가역적이므로 예방만이 유일한 해결책이라고 하겠다.

  • PDF

Trends of Long-term Ozone Concentrations in Seoul (서울지역 오존과 기상인자와의 관계 및 장기간 오존농도 분포 추세)

  • 한진석;마창민;조창래;진형아;정일록
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.157-159
    • /
    • 2000
  • 일반적으로 광화학반응에 의해 생성되는 오존은 전구물질(precursor)의 발생지역 뿐만아니라 바람에 따라 수송(transport)되어 오염원이 없는 외곽지역에 영향을 주기도 하는데, 지역적 규모(regional scale)이상의 수평적인 오존 수송을 나타낼 수 있다. 따라서 오존오염은 국지적 현상과 수송에 의한 복합적인 오염현상으로 나타나므로 지리적으로 인접한 수도권지역은 오존 및 전구물질의 유ㆍ출입이 발생하여 서풍일 경우 인천, 서울, 구리, 춘천까지 시간대별로 고농도의 오존이 관측되기도 한다. (중략)

  • PDF

Trends of Long-Term High Concentrations Ozone in Seoul Metropolitan Area (수도권지역의 장기간 고농도 오존 경향 분석)

  • 마창민;진형아;박철진;한진석;최양일
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.57-57
    • /
    • 2000
  • 광화학반웅에 의해 생성되는 오존은 전구물질(precursor)의 발생지역 뿐만아니라 바람에 따라 수송(transport)되어 오염원이 없는 외곽지역에 영향을 주기도 하는데, 지역적 규모(regional scale) 이상의 수평적인 오존 수송을 나타낼 수 있다. 따라서 오존오염은 국지적 현상과 수송에 의한 복합적인 오염현상으로 나타난다. 따라서 지리적으로 인접한 수도권지역은 오존 및 전구물질의 유·출입이 발생하며, 서풍일 경우 인천, 서울, 구리, 춘천까지 시간대별로 고농도의 오존이 관측되기도 한다. (중략)

  • PDF