• Title/Summary/Keyword: 교합면

Search Result 406, Processing Time 0.041 seconds

INTERRATER RELIABILITY OF CARIES DIAGNOSIS BY LASER FLUORESCENCE (레이저형광 우식진단법의 검사자간 신뢰도에 관한 연구)

  • Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.668-672
    • /
    • 2001
  • The purpose of study was to measure the interrater reliability of the caries diagnostic instrument, Diagnodent(KaVo, Germany), using a new laser fluorescence technique. Occlusal surfaces and smooth surfaces of one hundred extracted human premolars and molars were examined by four dentists. Pearson correlation coeffcients were 0703 to 0.870 for occlusal surfaces and 0.764 to 0.932 for smooth surfaces (P<0.01, all). Reliability coefficients which were calculated by intraclass correlation coefficients were 0.9450 for occlusal surfaces and 0.9605 for smooth surfaces. Therefore, the interrater reliability of caries diagnosis by Diagnodent is very high, and the rater training would be necessary more for occlusal surfaces than for smooth surfaces.

  • PDF

IS 지식에 대한 IS 실무자와 전공 교수 간의 인식 차이 분석

  • Lee, Hyeon-Woo;Lee, Hye-Jin;Go, Seok-Ha
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2007.05a
    • /
    • pp.281-299
    • /
    • 2007
  • IS/IT 분야 실무자가 지니고 있어야 한다고 생각되는 지식과 전문 기술들을 '지식/능력 영역'과 '소프트웨어 전문 기술 영역'으로 구분하여 각각 세부 항목을 명세하였다. 그리고 분류된 두 영역에 대하여 IS/IT 분야 실무자가 생각하는 필요한 지식 및 전문 기술들의 중요도와 IS/IT 전공 교수가 생각하는 IS/IT 실무자에게 필요한 지식 및 전문 기술들의 중요도를 조사하여 두 그룹간의 인식차 비교를 시도하였다. 조사지역은 실무자는 충청지역 및 수도권 지역에 분포하는 SI 업체를 대상으로 이루어 졌다. IS/IT 실무자를 대상으로 한 조사는 실무자 본인의 일장에서 IS/IT 실무자가 갖추어야 된다고 판단되는 지식 및 전문 기술들의 중요도를 측정하였다. 그와 더불어 그들이 수행하는 IS 활동에 대하여 투자한 시간을 기준으로 군집분석을 실시하여 세가지 그룹으로 구분하여 실무자 전체와 세 그룹간의 비교가 가능하도록 조차되었다. 비교 결과, 지식/능력 영역에서는 IS 실무자들이 상대적으로 '하드웨어에 대한 지식', '특정 조직', '운영체제에 대한 지식'에 대해 더 높은 중요도를 부여하고 있는 것으로 나타났다. 소프트웨어 전문 기술 영역에서는 실무자보다 전공교수가 생각하는 중요도가 보편적으로 더 높게 나타났다. 전공 교수는 '프리젠테이션 도구', '객체지향 언어(C++, Java 등)'에 4점 대의 높은 점수를 주어 중요한 것이 무엇인가 하는 인지가 있는 것으로 보이나 실무자 그룹에서는 특별히 중요시 여기는 항목이 명확히 드러나지 않고 보편적인 값이 median 값 주변에 위치하고 있다. 이는 현재 실무자들이 빠르게 변화하고 있는 IS/IT 환경에서 본인의 경력경로 (career path)을 위해 무엇이 중요한 갓인지 아직 명확히 하고 있지 못하는 것으로도 해석이 가능하다. 자세한 비교/분석 및 해석은 현재 진행 중이며, 여러 흥미로운 해석이 가능할 것으로 기대 된다.합형 파괴가 증가하는 경향을 나타내었다. 이상의 결과로, 상아질 접착제의 접착단계/과정이 결합내구성에 영향을 미침을 알 수 있었다. 따라서 접착과정의 단순화가 반드시 접착에 효과적이라고 할 수 없다.는 저작 운동 잔에는 2군에서 Heliomolar가 Pyramid보다 변연적합도가 우수하였고 (p < 0.05) 그 외의 군에서는 유의차가 없었으며, 저작 운동 후에는 모든 군에서 재료간 유의차가 없었다. 각 부위별 변연적합도를 비교하면, 저작 운동 전 Pyramid에서는 교합면 변연에서는 4군이 2군에 비해 높은 변연적합도를 보였고 (p < 0.05), 인접면과 치은면에서는 군 간 유의차를 보이지 않았다. Heliomolar에서는 교합면 변연에서 2, 4군이 1군에 비해 높은 변연적합도를 보였고 (p < 0.05), 인접면과 치은면에서는 군간 유의차를 보이지 않았다. 저작 운동 후 Pyramid에서는 교합면 변연에서는 3군이 1, 2군에 비해 높은 변연적합도를 보였고 (p < 0.05), 인접면과 치은면에서는 군간 유의차를 보이지 않았다. Heliomolar에서는 교합면에서 2, 3, 4군이 1군에 비해 변연적합도가 높았으며 (p < 0.05), 인접면과 치은면에서는 군간 유의차를 보이지 않았다 이번 연구를 통하여 복합레진을 간헐적 광중합시킴으로써 변연적합도가 향상될 수 있음을 알 수 있었다.시장에 비해 주가가 비교적 안정적인 수준을 유지해 왔다고 볼 수 있다.36.4%)와 외식을 선호(29.1%)${\lrcorner}$ 하기 때문에 패스트푸드를 이용하게 된 것으로 응답 하였으며, 남 여 대학생간에는 유의한 차이(p<0.05)가 인정되었다. 응답자의 체형은 ${\ulcorner}$적당하다${\lrcorner}$고 응답한 경우가 가장 많이 이러한 음식을 즐겨 먹었으며(49.5%), 그 다음은 뚱뚱한 경우도 비교적 많이 먹고

  • PDF

What would we meet for the implant dentistry: A Case Report (임플란트를 하면서 만나게 되는 문제들: 증례보고)

  • Lee, Jung-Sam
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.49-67
    • /
    • 2015
  • Since the implant became the important treatment modality in dentistry, the research and clinical effort to mimic natural tooth appearance have been pursued. While the rehabilitation of mastication and occlusal appearance was focused in the past, more esthetic and functional restoration was preferred recently. To fulfill this demand, the clinicians should consider the axial contour, papilla space, subgingival appearance, as well as the shape of occlusal surface. In the surgery part, there have been significant advances in the adequate formation of bone and soft tissue through the careful reflection on the surgery time and incision. When the dentist has good knowledge about this aspect and passion for the final product, he or she can acquire better results.

A case of direct restore using 4-META/MMA-TBB resin containing organic filler in patients with severe occlusal surface wear and enamel fracture (심한 교합면 마모 및 교두 파절 환자에서 유기필러를 함유한 4-META/MMA-TBB 레진을 활용한 직접수복 증례)

  • Dae-Sik Kim;Gyeong-Je Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.222-228
    • /
    • 2023
  • Attrition is the loss of tooth hard tissue due to contact between teeth, and in severe cases, dentin is exposed, accompanied by selective corrosion and excessive wear of teeth, which is called cupping. If these lesions are left untreated, the size of the lesion gradually increases, breaking the unsupported enamel, resulting in a decrease in aesthetics and chewing function. In this case report, patients with cupping and enamel fracture due to severe attrition were directly restored using a resin with soft properties containing organic fillers. In the follow-up observation six years later, most of the filling of the occlusal surface was eliminated, but the filling on the buccal surfaces remained relatively intact, and it was confirmed that this type of resin was suitable for the area where the occlusal force was relatively weak rather than the area where the occlusal force was greatly applied.

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.

Considerations for increasing denture stability: a case report (의치의 안정성을 증대시키기 위한 고려 요소: 증례보고)

  • Kim, Jiyeon;Kim, Hyeong-Seob;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.311-317
    • /
    • 2012
  • When wearing complete dentures, patients want to function naturally within a physiologically stable range. To do this, recovery of esthetics, biologically stable arrangement and contour, and occlusal contacts with denture stability are necessary. In this case report, a complete denture patient of adverse conditions was presented. To increase stability of the dentures, functional impression was made by border molding using the neutral zone. The dentures were checked for physiological centric relations and stable occlusion. The clinical results showed satisfactory results on function and esthetics.

Full mouth rehabilitation using zirconia crown in severe worn dentition: a case report (마모가 심한 환자에서 지르코니아 크라운을 이용하여 전악 수복한 증례)

  • Park, Jung-Hyun;Sohn, Sang-Hyuk;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.202-208
    • /
    • 2016
  • The progressive attrition of teeth is a normal process by aging. However, excessive tooth wear with decreased vertical dimension of occlusion and collapse of occlusal plane may cause pathologic pulpal condition, occlusal disharmony and functional disorders. In this case, a patient with severely worn dentition was treated. Diagnostic wax-up was performed at the increased vertical dimension. After evaluation of provisional restorations for 12 weeks, final restorations were fabricated with zirconia crown and routine clinical assessments were made. Esthetically and functionally satisfactory results were obtained.