• Title/Summary/Keyword: 교정표준기

Search Result 125, Processing Time 0.038 seconds

Intercomparison of vacuum standards of Korea, United Kingdom, and Japan (진공표준의 국제비교 연구)

  • 홍승수;신용현;임종연;이상균;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.308-313
    • /
    • 1997
  • TDS (Thermal Lkso~ption Spectroscopy)system, for diagnosis of CRT manufacturing process, was designed and constructed. Outgassings and themla1 desorptions from the part or materials of CRT can be measured and analysed with this system at various temperatures. The system is consisted of 3 pirrts. vacuum chamher and pumping system with variable conductance, sample heating stages & their controller, and outgassing measurement devices, like as ion gauge or quadrupole mass spectrometer. The ultimate pressure of the system was under $1\times10^{-7}$ Pa. With the variable conductance system, the effective pumping speed of the chamber could he controlled from sub 11s to 100 11s. The effective pumping speed values were determined by dynamic flow measurement principle. The temperatures and ramp rate of sample were controlled by tungsten heater and PID controller up to $600^{\circ}C$ within t $\pm 1^{\circ}C$$difference to setting value. Ion gauge & QMS were calibrated for quantitative measurements. Some examples of TDS measurement data ;ind application on the CRT process analysis were shown.

  • PDF

Establishment of Ultrahigh Vacuum Standard down to $10^{-10}$ torr Range ($10^{-10}$ torr까지의 초고진공 표준 확립)

  • Hong, Seung-Su;Im, Jae-Yeong;Park, Jae-Hong;Sin, Yong-Hyeon;Lee, Cheol-Ro;Jeong, Gwang-Hwa
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.2
    • /
    • pp.139-144
    • /
    • 1993
  • The dynamic calibration system which can calibrate the ultrahigh vacuum pressure down to $10^{-10}$torr has been fabricated. The production and control of minute flow of $10^{-6}~10^{-9}$torr L/s range is done by a porous plug connected to the high vacuum standards system. The base pressure of the UHV standards system down to $10^{-11}$torr range was obtained by refrigerator type cryopump, whose pumping speed is known to be constant. By using the UHV standards system, 2 extractor gauges and 1 nude ion gauge were calibrated and their linearities and scatterings were studied.

  • PDF

Development and It's Characteristics of AC Resistance Standards for Maintaining National Standard (국가표준 유지용 교류저항 표준기 개발 및 그 특성)

  • Kim, Han-Jun;Yu, Kwang-Min;Kang, Jeon-Hong;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2055_2056
    • /
    • 2009
  • 국가표준을 유지하기위한 표준기급의 교류저항은 상품화된 것이 외국에서 한 종류 있으나 고정된 기름 항온조에서 유지를 해야 하고, 정전차폐가 어렵고, 교류에서 측정단자의 호환성이 어렵고 가격도 대단히 비싸다. 또한 저항체가 지지대 역할을 하는 원형 보빈에 감겨져있는 선으로 구성되어서 국제비교시나 혹은 이동교정시에 기계적인 구조의 변화로 저항 값에 영향을 받기가 쉽다. 이러한 단점들을 극복한 교류저항 표준기가 개발이 되었다. 개발된 표준기는 저항체의 기계적 구조에 의한 변화를 막기 위해서 non-inductive 구조의 metal foil element로 제작된 것을 사용하였으며, 각각의 저항체에 개개의 항온조를 체택함으로서 온도의 안정성과 이동의 편리를 함께 만족되도록 하였다. 제작된 교류저항 표준기의 특성은 온도 안정도가 ${\pm}5$ mK/d, 저항값의 안정도가 ${\pm}0.01{\mu}{\Omega}/{\Omega}/d$, 1년간의 장기안정도가 $1{\mu}{\Omega}/{\Omega}$ 이하로 측정이 되었다. 개발된 교류저항 표준기는 교류저항분야 국가표준유지 및 소급에 사용이 된다.

  • PDF

Mathematical Model Expression of Portable Calibration System for Float Type Water Level Meters (부자식 수위계를 위한 이동형 교정시스템의 수학 모델)

  • Hong, Sung-taek;Shin, Gang-wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1964-1972
    • /
    • 2017
  • K-water have been operating as an International accredited calibration organization for ISO 17025 regarding float, ultrasonic and radar type since 2008. Due to the absence of on-site calibration system, water level meter could only be calibrated from a laboratory. Therefore K-water institute developed an mobile calibration system for water-level meter in 2015 to calibrate the water-level meter on site. The mobile calibration system was certificated by KOLAS(Korea Laboratory Accreditation Scheme) in 2016. In this paper a mobile calibration system, which is a method to calibrate float type water level meter on site, is established. A mathematical equation was derived by reviewing characteristics of standard equipment and measurement. By developing the mobile calibration system, it is possible to achieve reliability of data through scientific system operation on hydrological data.

Development of a Residual Gas Analyzer Calibration System (잔류기체 분석기 교정장치 개발)

  • Hong, S.S.;Lim, I.T.;Kim, J.T.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.91-98
    • /
    • 2007
  • The Korea Research Institute of Standards and Science (KRISS) has developed a residual gas analyzer (RGA) calibration system and measured gas sensitivities for two different types QMSs using nitrogen, argon, and helium. Different gas sensitivities were identified according to mass and pressure, so it was revealed that the gas sensitivity correction is necessary for proper use of mass spectrometers.

Development and Verification of Evaluation Technique for High Voltage Capacitance Bridge (고전압 전기용량 브리지 평가 기술 개발 및 검증)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2059_2060
    • /
    • 2009
  • 본 연구에서는 표준 용량기와 표준 저항을 이용하여 전기용량 브리지의 손실계수와 커패시턴스 비를 측정하여 전기용량 브리지를 평가하는 방법을 개발하였다. 이를 적용하면 기존의 해외 인증기관에서 성능평가를 의뢰했을 때 소요되는 교정기간을 단축하고, 교정 비용을 감소시킬 수 있다. 또한 현장에서 사용되고 있는 장비를 해외 인증기관에 교정 의뢰할 경우 그 기간 동안 장비를 사용할 수 없는 문제를 해결할 수 있다. 측정 범위는 손실계수의 경우 $1{\times}10^{-6}{\sim}7.5{\times}10^{-3}$의 범위까지 광범위하게 측정하였고, 커패시턴스 비는 $C_N{\times}0.1{\sim}C_N{\times}10^3$�劉沮� 측정하였다. 이로부터 제조사에서 제공하고 있는 전기용량 브리지의 성능을 확인이 가능하게 되었다.

  • PDF

Torque Standards and Evaluation (토크 표준 및 평가 연구 동향)

  • 박연규;김민석;김종호;강대임
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.26-31
    • /
    • 2004
  • 일반적인 공업 제품은 다수의 부품들로 이루어져 있다. TV 등과 같은 가전제품은 천여개, 자동차는 만여개, 그리고 항공기는 십만여개의 부품으로 구성된다. 여러 개의 부품은 다양한 방법으로 조립되어 완제품을 이룬다. 자동차의 제조와 같은 기계공업 분야에서 가장 일반적인 조립방법은 볼트 또는 나사를 이용하는 방법이다.(중략)