• Title/Summary/Keyword: 교정성

Search Result 2,233, Processing Time 0.033 seconds

Implementation of Korean Error Correction System (한국어 오류 교정 시스템의 구현)

  • Choi, Jae-hyuk;Kim, Kweon-yang
    • The Journal of Korean Association of Computer Education
    • /
    • v.3 no.2
    • /
    • pp.115-127
    • /
    • 2000
  • Korean error detectors of word processors have defects such as inconvenience that users choose one of error groups, lower detecting rate of 60%, and slow processing time. In this study, I proposed a resolution method of these defects. For these, I applied bidirectional longest match strategy for morphological analysis to improve processing time. I suggested dictionaries and several algorithms such as seperation of compound noun and assistant declinable words, correction of typing error to improve processing time and to guarantee correction accuracy. I also suggested a distinguishable method for dependent noun/suffix and Josa/Eomi where many ambiguities are generated, and a distinguishable method for Korean "로써/로서" to improve the reliability of the correction system.

  • PDF

Clinical Estimation of Corrected State with Change in Vertex Distance (정점간거리 변화에 따른 교정상태의 임상 평가)

  • Kim, Jung-Hee;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • Purpose: This study was conducted to estimate the changes of corrected diopter and corrected visual acuity with the change in vertex distance. Also we aimed to provide basic data for refraction test. Methods: Using the trial lens, we measured the corrected diopter and corrected visual acuity after performing binocular balance test. We measured the changes of corrected diopter and corrected visual acuity in change of vertex distance. We analyzed statistical significance and relations between vertex distance and corrected diopter and corrected visual acuity. Results: There was no difference in corrected diopter with the change of vertex distance within -1.00D, but the corrected diopter increased with it over - 1.25D. In particular, the change of diopter was largest when the vertex distance increased 15 mm. At over 11.00D, there was large changes of diopter with the changes of vertex distance at 5 mm, 10 mm and 15 mm. On correlation analysis between the vertex distance and the corrected diopter, there was strong correlation (r=0.999 at 5 mm increase of vertex distance, r=0.982 at 10 mm increase and r=0.957 at 15 mm increase) and also there was significant (p<0.01). At the change of visual acuity in increased of vertex distance, the range of a decrease in visual acuity was large when the changes of vertex distance was largest. On correlation analysis between the vertex distance and the corrected visual acuity, there was strong correlation (r=0.969 at 5 mm increase of vertex distance, r=0.985 at 10 mm increase and r=0.994 at 15 mm increase) and also there was significant (p<0.01). Conclusions: The vertex distance was very important at the refraction test and at wearing spectacle. On correlation analysis between the vertex distance and the corrected diopter, and the corrected visual acuity, there was strong correlation and statistically significant. Therefore, the vertex distance should be kept at the refraction using trial lens, and the best fitting was made not to slipping forward, and so we suggested regular refitting of spectacle and the managing method of spectacle were educated to the spectacle wearers.

정적형 유량계를 이용한 소닉노즐의 유출계수 교정 방법에 관한 연구

  • Sin, Jin-Hyeon;Gang, Sang-Baek;Go, Mun-Gyu;Im, Jong-Yeon;Jeong, Wan-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.45-45
    • /
    • 2010
  • 반도체 및 디스플레이 산업에 사용되는 진공펌프의 효율이 증대됨에 따른 성능 평가 기술의 향상 과 미세 유량을 조절 및 측정할 수 있는 시스템의 개발이 요구되고 있다. 유량 시스템 중 소닉노즐은 기체 유량 측정 표준기로 사용되고 있다. 또한 유량 측정에 있어서 사용상의 편리성, 이동성, 재현성 등 여러 가지의 장점을 가지고 있어 산업 현장에서 많이 사용되고 있다. 본 연구는 소닉노즐을 넓은 유량 범위에서 사용할 수 있도록 소닉노즐의 유출계수 교정을 목적으로 한다. ISO 9300에서 제시한 사양에 맞추어 목 직경 0.03 mm와 0.2 mm 그리고 1.6 mm의 소닉노즐을 제작하였다. 한국표준과학연구원에서 진공용 유량측정 장치로 개발된 정적형 유량계를 이용하여 제작된 3 종의 소닉노즐 유출계수를 확장불확도 3% 이내로 교정하였다. 교정된 소닉노즐의 유량 측정범위는 약 0.6~90, 000 cc/min 범위를 갖는 것으로 나타났으며, 사용유동 조건에 해당되는 레이놀드 수(Reynolds number) 범위는 26~75, 700 으로 확인되었다. 이러한 결과는 교정된 소닉노즐을 이용하여 진공공정에서 필요한 극 미세 유량의 정밀측정을 가능하게한 새로운 연구결과로 판단된다. 교정된 소닉노즐을 이용하여 진공펌프의 배기속도 측정결과는 기 구축된 정적법을 이용한 배기속도 측정결과와 3% 이내의 오차범위내로 매우 잘 일치함을 보였다. 교정된 소닉노즐은 향후 반도체 및 디스플레이 공정에 사용되는 다양한 진공펌프들의 배기속도를 현장에서 간단하게 평가할 수 있는 '현장 성능평가 장치'에 활용할 예정이며, 현재 공정현장에서 배기속도 측정에 널리 사용 중인 MFC를 대체할 수 있을 것으로 예상된다.

  • PDF

A Pen-based Proofreading Interface in XML Documents (XML 문서에서의 펜 기반 교정 인터페이스)

  • Sohn Won-Sung;Kim Jae-Kyung;Choy Yoon-Chul;Lim Soon-Bum;Kim Woo-Sung
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.2
    • /
    • pp.231-242
    • /
    • 2006
  • Accurate proofreading Interface requires resolving the ambiguity that occurs when the system determines the relations between the free-form by the user and editing scopes of the document. Proofreading for structure documents such as XML/XHTML involves modification of document structures and modified document also should follow the pre-defined DTD. This paper present a CPI (Context-based Proofreading Interface) based on the XML. The CPI supports free-form drawing of correction marks and provides context-based scope recognition and revision methods. CPI provides both implicit and explicit modification methods for document structures. As a result, the correction mark information produced in this paper includes more accurate scope information than that in other systems.

A Study on the Reliability of Corrected Diopter according to Subjective refraction instrument (자각식굴절검사기기에 따른 교정굴절력의 신뢰도에 관한 연구)

  • Lee, Hark-Jun;Kim, Jung-Hee;Ryu, Kyung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.281-286
    • /
    • 2010
  • Purpose: This research provided basic data for refraction by comparing the corrected diopter of trial lens and phoropter. Methods: We compared the corrected diopter of trial lens and phoropter, and analyzed statistical significance and relations of the spherical lens corrected diopter and cylindrical lens corrected diopter according to the types (trial lens and phoropter) of subjective refractive instruments. Also we analyzed statistical significance and relations between cylindrical lens corrected diopter at the astigmatism and the types (trial lens and phoropter) of subjective refractory instruments. Results: When we measured the corrected diopter of simple myopia, the mean value for corrected diopter was S-2.74D using the trial lens and S-2.65D using the phoropter. So the corrected diopter was 0.09D smaller when measured by phoropter. The degree of astigmatism was measured C-0.81D using the trial lens and C-0.77D using the phoropter which showed that the measured value was 0.04D smaller using the phoropter. On correlation analysis between the refractive instruments (trial lens and phoropter) and the corrected diopter, there was significant (p<0.01) strong correlation between refractory machine and corrected spherical diopter (r=0.996) and the correlation between refractory machine and corrected cylindrical diopter was r=0.986 and was also significant (p<0.01). Conclusions: The use of phoropter than trial lens was more desirable when performing refraction on high myopia (simple refractive error, high astigmatism), and when using trial lens, you should consider the vertex distance and the gap between overlapped lenses before prescription.

THE INITIAL TISSUE CHANGE TO THE IMMEDIATE ORTHODONTIC FORCE FOLLOWING BUCCAL HORIZONTAL SUBAPICAL OSTEOTOMY OF MAXILLA (상악골 협측 수평 골절단술 직후 교정력에 의한 초기 치아주위 조직반응)

  • Hong, Kwang-Jin;Ahn, Byoung-Keun
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.101-110
    • /
    • 1995
  • The purpose of this study was to observe the tissue response to the orthodontic force applied immediately after buccal horizontal subapical osteotomy of maxilla. Five mongrel cats weighing about 2.5 Kg were used for this experiment. The left upper canine and premolar of each cat served as a experimental side and the right ones as a control side. On the experimental side, a 100gm orthodontic force was applied between the upper canine and premolar immediately after the osteotomy. On the control side, the same orthodontic force was applied without the osteotomy. After 7days, the experimental animals were sacrificed. The results were as follows: 1. In the pressure zones of the experimental group, significant increase of osteoclasts and direct resolution along the alveolar bone surface was observed as compared with those of the control group. 2. In the pressure 2ones of the experimental group, a less extensive hyalinized zone was observed than those of the control group. 3. In the pressure zones of both group, no root resorption was found. 4. Tn the tension zones of the experimental group, new bone deposition increased along the alveolar bone surface as compared with those of the control group. In conclusion, the results suggest the possibility that early orthodontic treatment after orthognathic surgery may have some benefits if the stability of the repositioned segment at surgery is secured.

  • PDF

우주환경모사용 열진공챔버 고진공게이지 교정결과 검토

  • Park, Seong-Uk;Seo, Hui-Jun;Jo, Hyeok-Jin;Im, Seong-Jin;Go, Tae-Sik;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.114.1-114.1
    • /
    • 2013
  • 우주궤도환경은 고진공 환경이며, 태양복사열에 의한 고온환경 및 극저온환경이 반복되는 가혹한 환경이다. 위성체의 성공적인 임무 수행을 위해 지상에서 철저한 우주환경시험을 거쳐 기능 및 작동상태를 점검해야 하며, 이를 위해서는 $10^{-6}$ Torr 이하의 고진공 및 $-180^{\circ}C$ 이하의 극저온 모사가 가능한 열진공챔버와 같은 우주환경모사장비가 반드시 필요하다. 한국항공우주연구원에서는 다양한 크기의 열진공챔버를 보유, 가동 주이며, 챔버 내부의 진공도를 측정하기 위한 진공게이지의 교정을 매년 실시하고 있다. 또한 교정기관을 통한 교정 이외, 보유하고 있는 표준챔버를 이용한 자체 교정을 실시하여, 진공도의 신뢰성 점검 및 보증을 하고 있다. 본 논문에서는 표준챔버를 이용한 고진공게이지 교정 방법을 소개하며, 다년간의 교정결과를 검토하여 교정주기에 대한 견해를 기술하고자 한다.

  • PDF