• Title/Summary/Keyword: 교정굴절력

Search Result 76, Processing Time 0.02 seconds

Reliability of Autorefractometry after Corneal Refractive Surgery (레이저 굴절교정수술 후 자동굴절검사법의 신뢰성)

  • Lee, Ki-Seok
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.443-451
    • /
    • 2018
  • Purpose : To find out the reliability of autorefractometer after laser refractive surgery Methods : We measured and compared spherical and cylinder powers of those undergone LASEK surgery with 1.0 of naked vision after at least 3 months of the surgery with an autorefractometer(CANON Full Auto Ref-Keratometer RK-F1, Japan) and a retinoscope(Streak Retinoscope 18200, WelchAllyn, USA), and also applied spherical equivalent powers. The refractive status before surgery was divided into high, medium, and low myopia according to the results measured using an autorefractometer, and then analyzed again the reliability of the autorefractometer after surgery according to the preoperative refractive status. The agreement of two methods was identified using Bland-Altman(Bland-Altman limits of agreement(LoA)). Results : After the surgery, when comparing spherical, cylinder and equivalent powers in the whole data measured by autorefractometry and retinoscopy significant differences were found(p<0.01). According to the degree of refractive errors, all sort of refractive errors was shown significantly different(p<0.01) except for cylinder power of the medium myopia. In general, the refractive errors especially spherical and spherical equivalent powers by autorefractometry were shown a myopic trend from -0.38 D to -0.53 D. On the other hand, it was shown a hyperopic trend of approximately +0.30 D using retinoscopy. In comparison of two objective refractions, it was shown a myopic trend as $-0.51{\pm}0.45D$(LoA +0.36 D ~ -1.39 D) and compatible. Conclusion : Even though it would be positive in terms of compatibility of the methods, it is necessary that the glasses should be prescribed by subjective refraction since autorefractometry is shown myopic in those undergone the surgery and suffering from myopic regression.

A Study for the Reading Pupillary Distance and the Diopters (근용안경의 굴절력과 동공중심간 거리에 대한 연구)

  • Ruck, Do Jin;Shin, Jae Hyun;Park, Kyung Suk;Jun, Young Gi;Sung, Duk Yong;Kang, Sung Soo;Lee, Won Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.57-61
    • /
    • 1999
  • This is a study of measurement of inter Reading Pupillary Distance (P.D.) in 729 old aged farmers (aged over 50). The average of Reading Pupillary Distance (P.D.) in man (58.93mm) is bigger than in woman (57.82mm), and the O.C. of Ready-made Reading Spectacles is 68.98mm.

  • PDF

The Influence of the Front Surface Power and the Refraction Index on RMS Spot Diameter (전면 굴절력과 굴절률이 착락원의 크기에 미치는 영향)

  • Park, Seong-Jong;Shin, Cheol-Guen;Ju, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.57-63
    • /
    • 2003
  • To investigate the RMS SD(Root Mean Square Spot Diameter) in a back focal plane as the front surface power, the center thickness, and the refraction index vary, we use programs which are Cove V and LOSA 2.0, and consider a spectacle lens with back vertex power of -4.00D and diameter of 70 mm. We also consider the front surface power varied from 0.00 to 10.00D, the center thickness varied from 1.1 to 2.0 mm, and the indices which are $n_d$ = 1.498, 1.523, 1.586, and 1.660, respectively. As the front surface power increases the RMS SD in the back focal plane increase rapidly. When the refraction index increases, the RMS SD in the back focal plane decrease and the variation of RMS SD in the back focal plane decreases as the front surface power increases. When the center thickness of spectacle lens increases, the RMS SD in the back focal plane is constant and the edge thickness of that increases. We know from these results that the image in the back focal plane of a spherical spectacle lens improves as the front surface power increases and the refraction index decreases.

  • PDF

Analysis of the Eyeglasses Supply System for Ametropes in ROK Military (한국군 비정시자용 안경의 보급체계 분석)

  • Jin, Yong-Gab;Koo, Bon-Yeop;Lee, Woo-Chul;Yoon, Moon-Soo;Park, Jin-Tae;Lee, Hang-Seok;Lee, Kyo-Eun;Leem, Hyun-Sung;Jang, Jae-Young;Mah, Ki-Choong
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.579-588
    • /
    • 2018
  • Purpose : To analyze the eyeglasses supply system for ametropic soldiers in ROK military. Methods : We investigated and analyzed the supply system of eyeglasses for the ametropic soldiers provided by the Korean military. The refractive powers and corrected visual acuity were measured for 37 ametropic soldiers who wear insert glasses for ballistic protective and gas-masks supplied by the military based on their habitual prescriptions. Full correction of refractive error was prescribed for subjects having less than 1.0 of distance visual acuity, and comparison was held for inspecting the changes in corrected visual acuity. Suggestions were provided for solving the issues regarding current supplying system, and this study investigated the applicabilities for utilizing professional optometric manpower. Results : The new glasses supplied by army for ametropic soldiers were duplicated from the glasses they worn when entering the army. The spherical equivalent refractive powers of the conventional, ballistic protective and gas-mask insert glasses supplied for 37 ametropic soldiers were $-3.47{\pm}1.69D$, $-3.52{\pm}1.66D$ and $-3.55{\pm}1.63D$, respectively, and the spherical equivalent refractive power of full corrected glasses was $-3.79{\pm}1.66D$, which showed a significant difference(p<0.05). The distant corrected visual acuity measured at high and low contrast(logMAR) of conventional, ballistic protective and gas-mask insert glasses were $0.06{\pm}0.80$, $0.21{\pm}0.82$, $0.15{\pm}0.74$, $0.34{\pm}0.89$, $0.10{\pm}0.70$ and $0.22{\pm}0.27$, respectively, while the corrected visual acuity by full corrected glasses were increased to $0.02{\pm}1.05$, $0.10{\pm}0.07$, $0.09{\pm}0.92$, $0.26{\pm}0.10$, $0.04{\pm}1.00$ and $0.19{\pm}1.00$, respectively. There was a significant difference(p<0.05) except for the case of the low contrast corrected visual acuity of the conventional and gas-mask insert glasses. The procedure for ordering, dispensing, and supplying military glasses consists of 5 steps, and it was found that approximately two weeks or more are required to supply from the initial examination. Conclusion : The procedure of supplying the military glasses showed three issues: 1) a lack of refraction for prescription system, 2) relatively long length of time required for supplying the glasses, 3) an inaccurate power of supplied glasses. In order to solve those issues, in the short term, education is necessarily required for soldiers on the measurement of the refractive powers, and in the near future, further standard procedures for prescription of glasses as well as the securement of optometric manpower are expected.

A Study for Exact Spherical Diopter by Cross Cylinder Lens and Red·Green Card Method (크로스 실린더법과 적·녹검사를 이용한 정밀구면 굴절력에 관한 고찰)

  • Yoon, Kyounghan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.39-43
    • /
    • 1999
  • In this study, It obtained results that the exact spherical diopter to practice test by using Cross cyliner lens and Red Green Card method. In the test used to the 1750 eyes of middle and high school students. The results was as follows ; 1. Using Cross cylinder lens method, I tested a exact spherical diopter after accommodation. At -0.25 Dptr the ratio of spherical Dptr error limits were measured as 58% and at -0.75 Dptr they were oppeared as 1%, at -1.00 Dptr they are not measured. In this method, the error limits of exact spherical Dptr was 91% from 0 Dptr to -0.25 Dptr. 2. Using Red Green Card method, they were measured as 45% at -0.25 Dptr. and measured as 20% at -0.50 Dptr. From the result of these test, Cross cylinder lens method was a better detailed method than Red Green Card method.

  • PDF

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.

Diurnal fluctuations of vision in myopes (근시안의 일일 시럭변동에 관한 연구)

  • Park, Sang-Chul;Sung, A-Young;Kim, Tae-Hyun;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2005
  • Subjective and objective visions were measured on young adults(mean 21 yrs, 126 eyes) who were free of any ocular diseases and laser surgery and none wore contact lenses. The aim of this study was to investigate the diurnal variation of vision through subjective and objective measurements. Subjective visual acuity were measured at 5 m three times a day, morning(8:00 AM-10:00 AM), noon(12:00 PM-2:00 PM) and afternoon(4:00 PM-6:00 PM). The instrument used for objective refraction right after visual acuity measurement was Nvision-K 5001(shin-nippon) which unique in being able to disregard subject's accommodation because of its unrestricted viewing conditions. Also, we measured that three times and then calculated the average values. The result showed that an average subjective visual acuity in the morning, noon, afternoon were 0.256(${\pm}0.263$), 0.266(${\pm}0.276$), 0.242(${\pm}0.249$) respectively. Average spherical equivalent power in objective refraction of right eyes showed -3.416 D(${\pm}2.907$), -3.359 D(${\pm}2.735$), -3.297 D(${\pm}2.709$) respectively and dioptric power was decreased from morning to afternoon. Vision changed throughout the day in both subjective and objective measurements nevertheless its variations were statistically insignificant(p<0.05). Therefore it does not seem to matter of time for either visual acuity test or refraction.

  • PDF

A Study for Accommodation Power on the Basis of Near Power and Correction Power for distance (근용 도수와 원용 교정도수를 근거로 한 조절력에 관한 연구)

  • Lee, Jeung-Young;Park, Eun-Kyu;Seo, Jeung-Ik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.107-110
    • /
    • 2007
  • Analysis of accommodation amplitude has been conducted for 137 adults, living in rural area, aged from their fifties to eighties. The methods included measurement of correction power for distance via auto-refractometer, measurement of near power based on trial frame and trial lens set, and calculation of effective accommodation amplitude using 1/2 and 2/3 of the maximum accommodation amplitude. The research results for participants aged in their fifties, sixties, seventies, and eighties showed 1.84~2.46D, 1.55~2.06D, 1.43~1.90D, and 1.22~1.62D respectively. It is relatively higher than the existing knowledge regarding accommodation amplitude associated with age.

  • PDF

Effects of Wearing Corrective Glasses for Presbyopia on Age-related Hyperopic Shifts and Reading Addition (노안보정용 안경 착용이 연령관련 원시화와 근용가입도 변화에 미치는 영향)

  • Lee, Koon-Ja;Kim, Jin-Han;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.65-73
    • /
    • 2009
  • Purpose: This study was conducted to investigate the changes in distance refractive power and reading addition that occur after wearing corrective glasses for prebyopia. Methods: The subjects aged 42 to 75 years who had no ophthalmologic diseases and did not undergo cataract or retina surgery, had a corrected visual acuity of 20/20 and did not have a previous history of wearing corrective glasses for presbyopia. These subjects were divided into 3 groups: the control, reading spectacles and multifocals wearing group and they were measured for distance refractive power and reading addition at their visit. The maximum follow-up period was 73 months. Results: As for distance refractive power, the power tends to shift to hyperopia depending on age (r=0.486, p<.001) and 50.0% of the subjects increased plus power during this study period. Plus power Increments per year in distance refractive power in the reading spectacle wearing group were significantly different with control and multifocals wearing group (p<.05). On the other hand, the multifocals wearing group's increments were not different with control. Increments in reading addition were also increased in the reading spectacles group than in the control and multifocals wearing groups (p<.05). Conclusions: The age related hyperopic shift could be occurred in the elderly people, routine refraction is mandatory. And reading spectacles could induce an age related hyperopic shift and the additional need for reading addition that the prescription of multifocals may reduce changes in distance refractive power and reading addition.

  • PDF

Changes in Accommodative Function after VDT Work (VDT 작업 후의 조절기능 변화)

  • Seo, Eun-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.285-291
    • /
    • 2012
  • Purpose: This study was conducted to research any effect on visual function related to accommodation by VDT work. Methods: The refraction power, accommodative lag, accommodative facility, relative accommodation, amplitude of accommodation and blink rate were measured before and after VDT work for 2 hours on 48 university students (16 males and 32 females), without abnormal accommodative function and systemic and ocular disease, who had never undergone corrective eye surgery. All examinations were performed with distant refraction, and a survey was conducted on the items related to subjective symptoms of VDT syndrome. Results: After 2 hours of VDT work, refractive power increased by 0.23 D, the amount of change in accommodative lag were $0.17{\pm}0.42D$ in the right eye and $0.23{\pm}0.47D$ in the left eye (t=2.26, p=0.03). There were statistically significant differences. Both the accommodative facility and relative accommodation and amplitude of accommodation were decreased after work. However, blink rate were increased. After VDT work, 33.4% of the subjects showed subjective symptoms of asthenopia and 33.3% of them showed shoulder pain. Conclusions: As a result, the accommodative lag increased in response to the two hours of VDT work, and overall accommodative functions were decreased. In addition, as symptoms of providing visual strain, asthenopia showed the most prominent subjective symptoms.