• Title/Summary/Keyword: 교정값

Search Result 514, Processing Time 0.033 seconds

Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter (자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2015
  • Purpose: To evaluate the reliability of refractive power by comparing the marked refractive power in an automatic phoropter and actually measured spherical/cylindrical refractive power. Methods: Actual refractive power of minus spherical lens and cylindrical lens in an automatic phoropter was measured by a manual lensmeter and compared with the accuracy of marked refractive power. Furthermore, combined refractive power and spherical equivalent refractive power of two overlapped lenses were compared and evaluated with the refractive power of trial lens. Results: An error of 0.125 D and more against the marked degree was observed in 70.6% of spherical refractive power of spherical lens which is built in phoropter, and the higher error was shown with increasing refractive power. Single cylindrical refractive power of cylindrical lens is almost equivalent to the marked degree. Combined spherical refractive power was equivalent to spherical refractive power of single lens when spherical lens and cylindrical lens were overlapped in a phoropter. Thus, there was no change in spherical refractive power by lens overlapping. However, there was a great difference, which suggest the effect induced by overlapping between cylindrical refractive power and the marked degree when spherical lens and cylindrical lens were overlapped. Spherical equivalent refractive power measured by using a phoropter was lower than that estimated by trial glasses frame and marked degree. The difference was bigger with higher refractive power. Conclusions: When assessment of visual acuity is made by using an automatic phoropter for high myopes or myopic astigmatism, some difference against the marked degree may be produced and they may be overcorrected which suggests that improvement is required.

Studies on immobilization and application of beta-galactosidase II. Preparation and properties of the immobilized enzyme from Aspergillus niger CAD 1 (beta-Galaetosidase의 고정화 및 응용에 관한 연구 제2보: Aspergillus niger CAD 1의 효소 교정화 조건 및 고정화 효소의 성질)

  • Lee, Yong-Kyu;Cuun, Soon-Bae;Choi, Won-Ki;Chung, Ki-Chul;Bae, Suk;Kim, Kwan-Chun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.15 no.4
    • /
    • pp.40-46
    • /
    • 1986
  • The beta-galactosidase of Aspergillus niger CAD 1 described in previous report was immobilized to cellulose triacetate. The optimal conditions for immobilization of the enzyme were obtained when 13%(v/v) of the soluble enzyme (349 unit/ml) was entrapped in fiber prepared from 10%(w/v) cellulose triacetate in methylene chloride. The optimal temperature and pH for the activity of the immobilized enzyme were $45^{\circ}C$ and 4.5, respectively, which stowed the same values as those of the soluble enzyme. It was found that Km of the immobilized enzyme for lacotse exhibited high value compared with that of the soluble enzyme. The immobilized enzyme showed good storage stability, reusability, and also hydrolysis of lactose when introduced into skim milk and acidic whey.

  • PDF

A New Technique of Angioplasty of the Left Pulmonary Artery Using an Autologous Main Pulmonary Artery Flap (활로 4징 환자에서 자가 주폐동맥 플랩을 이용한 새로운 좌폐동맥 성형술)

  • 이창하;전양빈;이택연;이석기;백만종;김수철;이영탁
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.255-260
    • /
    • 2003
  • Background: Stenosis of the left pulmonary artery (LPA) after repair of tetralogy of Fallot (TOF) is troublesome. A new technique of LPA angioplasty using an autologous MPA flap was performed in patients with TOF Material and Method: From October 1998 to January 2001, 24 patients (median age; 10 months, range; 4 to 145 months) underwent total correction of TOF with LPA angioplasty using the autologous MPA flap. Five patients underwent pulmonary angioplasty without any patch over the MPA and LPA. The patches were required to enlarge only the MPA in 4 patients, and transannular RVOT widening was performed in 15. Result: There were no operative or late deaths. During follow-up (range: 6~42 months), reoperation for LPA stenosis was not required in any patients, but balloon angioplasty for branch pulmonary artery stenosis was performed in 3 patients. Echocardiography and CT angiography at the recent follow-up showed an obtuse angle between the MPA and LPA. Conclusion: Although further follow-up is needed, the angioplasty using the autologous MPA flap can be easily performed, avoiding patch-related complications, and allowing growth of the MPA flap. This angioplasty technique creates a more natural and obtuse angle between the MPA and LPA, which can minimize kinking of the LPA, especially in the patients who underwent transannular patch widening.

A study on the Derivation of GIUH-Clark Model (GIUH-Clark 모형의 유도에 관한 연구)

  • Lee, Byung Woon;Jang, Dae Won;Kim, Hung Soo;Seoh, Byung Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.731-736
    • /
    • 2004
  • 강우-유출과정의 수문학적 현상을 보다 정확히 분석하고 예측하는 기법으로 강우에 의한 유출의 반응을 나타내는 지체시간, 도달시간 등 수문학적 반응시간을 유역의 지형형태학적 인자들과 연계하는 방법이 많이 이용되고 있다. 이에 본 연구에서는 Clark방법과 지형형태학적 순간단위도(GIUH)를 이용하여 계측유역의 강우-유출반응을 모의하였고, 이를 관측된 값과 비교하여 미계측유역의 적용성 여부를 검토해보았다. 대상 유역의 하상지형인자 및 지형형태학적 특성은 Arc-View를 이용하여 구하였으며, 이를 기존의 문헌자료와 비교해보았다. Clark방법의 매개변수의 결정에 있어서 시간-면적곡선은 HEC-1의 무차원 식을 이용하였고, 도달시간은 Kirpich 공식을 이용하여 구하였으며, 저류상수는 Clark방법에 의해 추정된 순간단위도의 첨두유량이 Horton의 차수비의 함수로 구한 철두유량과 같아지는 값으로 결정하였다. 본 연구는 전적비교를 출구점으로하는 유역면적 $8.5km^2$인 설마천을 대상유역으로 하였으며, 모의된 강우-유출반응과 비교하기 위해 사용된 강우사상은 2002년의 8월 4일과 2002년 10월 6일의 10분 단위 우량이다. Clark방법과 GIUH를 이용하여 모의한 유출곡선과 관측된 유출곡선을 비교해본 결과 첨두유량은 8월의 강우사상 때는 $21\%$크게, 10월의 강우사상 때는 $35\%$작게 나타났다. 첨두시간은 모의된 경우가 각각 10분, 20분 빨리 도달하였다. 또한 이러한 결과는 유역의 도달시긴에 가장 민감하게 반응함을 알 수 있었다. 따라서, 유역의 도달시간 산정에 주의를 요한다면 프랙탈 차원이 유사한 미계측유역의 수문곡선 산정에 있어서 Clark방법과 GIUH를 이용하는 방법도 유용하다고 사료된다. 주는 각 수문인자 중 강우시간분포와 유효우량 산정방법 그리고 유출모형에 대해 자자 검토하였으며, 최종적으로 면적에 따른 임계지속기간과 유출량의 변화를 검토해 보았다.이를 각각의 경우의 해석해 결과와 비교${\cdot}$분석하였다. 후방추적 퍼프모형은 전방추적 퍼프모형에 비하여 사용된 퍼프수와 관계없이 작은 오차를 발생하였으며, 전체적으로 퍼프 모형이 입자모형보다는 훨씬 적은 수의 계산을 통해서도 작은 오차를 나타낼 수 있다는 것을 알 수 있었다. 그러나 Gaussian 분포를 갖는 퍼프모형은 전단흐름에서의 긴 유선형 농도분포를 모의할 수 없었고, 이에 관한 오차는 전단계수가 증가함에 따라 비선형적으로 증가하였다. 향후, 보다 다양한 흐름영역에서 장${\cdot}$단점 분석 및 오차해석을 수행한 후에 각각의 Lagrangian 모형의 장점만을 갖는 모형결합 방법을 제시할 수 있을 것으로 판단된다.mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하

  • PDF

A Study on the Branch Composition of an Optimum Polarization Diversity by Considering XPD in Indoor Radio Environments (실내무선 환경에서 XPD를 고려한 최적편파 다이버시티의 브랜치 구성에 관한 연구)

  • 하덕호;이주현;윤영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.302-311
    • /
    • 1999
  • In this paper, in order to suggest an optimal polarization diversity composition method in indoor radio wave propagation environments, the variation of the cross polarization discrimination(XPD) was theoretically analyzed by a computer simulation and compared to the actual measured data. From the results, it can be seen that the cross polarization discrimination of the case, a circularly polarized antenna was used at the transmitting end as well as the vertical and horizontal polarized antenna branches were used at receiving end (CV-CH), is lower than that of the case, horizontal polarized antenna at the transmitting end as well as the horizontal and vertical polarized antenna branches at the receiving end(HH-HV), and that of the case, vertical polarized antenna at the transmitting end as well as the vertical and horizontal polarized antenna branches at the receiving end(VV-VH). In this paper, to get more effective CV-CH polarization diversity composition, the amount of cross polarization discrimination values at the signals received by horizontal polarized antenna is compensated and the polarization diversity effect through the cumulative probability distribution is estimated. From the evaluation results, it was found that the polarization diversity effect was better at the compensated case than at the uncompensated case. On the other hand, it can be known that the polarization diversity effect is getting better as the cross polarization discrimination values are getting lower, and also be known that the effect can be improved if a transmitting antenna is composed of the ellipse polarized antenna by adjusting the axial ratio of the circularly polarized antenna and, a receiving antenna is made up of the vertical and horizontal polarized antenna branches.

  • PDF

Induction of the High Order Calibration Equation of Metal Oxide Semiconductor Gas Sensors (산화물 반도체식 가스센서의 입출력 고차 캘리브레이션 방정식 도출)

  • Park, Gyoutae;Kim, Kangmin;Lee, Hyeonggi;Yoon, Myeongsub
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.44-49
    • /
    • 2020
  • In this paper, a measuring circuit is designed through analyzing manufacture specification of the sensor based on MOS. And the best input-output polynomial are induced that really gas sensors are used in gas safety management industrial fields. Response characteristics of a MOS gas sensor is analysed by through sensor's output voltages are measured after standard gases with six kinds of concentrations are manufactured and are injected to the sensor. A lookup table is created by relations of sensor's output voltages by injecting gases with other concentrations. Because data of the formed lookup table are equal interval, a polynomial can be induced of method of approximation function. So the 5th polynomial of input-output for a sensor is defined, coefficients are calculated by using least squares method, and the 5th polynomial is completed for representing characteristics of the sensor. If the proposed polynomial is applied to gas leak detectors, an inverse transformation of polynomial and programing of array codes are recreated. In this research, polynomial is implemented with array types that intervals of values of a lookup table are one-fifth sampled and interpolated. The performance of proposed 5th calibration equation is verified that errors are reduced than a linear expression when tests are performed by measurement of concentrations against injection of standard gases.

THE CHANGES OF SERUM C-REACTIVE PROTEIN IN THE HEAD AND NECK INFECTION (두경부 감염 환자에서 혈청 내 C-Reactive Protein의 변화)

  • Lee, Ju-Hyun;Kim, Chin-Soo;Lee, Sang-Han;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.5-13
    • /
    • 2003
  • The purpose of this study is to determine the value of serum concentration of C-reactive protein(CRP) in comparison with ESR and leukocyte as the tools for diagnosis and follow-up study of infection. For this study, thirty-one patients with head and neck infection and thirty-two patients performed the orthognathic surgery were selected for experimental and control groups each other. we analyzed the blood sample daily to measure CRP, ESR and leukocytosis. The results of this study are as the following : 1. Serum C-Reactive Protein levels in the experimental group were higher than control group and the pattern of CRP changes continued to decline in both groups(P<0.001). 2. ESR changes in both groups were scattered without any special pattern. 3. Correlation between CRP and Leukocyte was higher than others(r=0.664, P<0.01). 4. In the Receiver Operating Characteristic(ROC) Curve of experimental group, rapid increase of CRP curve and Area under the curve(AUC) value, 0.774, indicate the high accuracy of estimation. 5. In experimental group, sensitivity of CRP, ESR, and Leukocytosis on recovery day were 83%, 17% and 71%. Based on the results of this study, we could conclude that determination of CRP is more useful method to diagnosis and follow-up study of infection than other commonly used variables in oral and maxillofacial region.

The Effect of Pelvic Tilt on Muscle Activity of Cervical Erector Spinae & Upper Trapezius While Using a Smartphone (골반경사에 따른 스마트폰 사용이 목세움근과 위등세모근의 근활성도에 미치는 영향)

  • Song, Seong-In;Kang, Jong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.97-103
    • /
    • 2017
  • The purpose of this study was to investigate muscle activity of cervical erector spinae & upper trapezius while using a smartphone according to anterior pelvic tilt & posterior pelvic tilt in sitting position. & we also want to obtain basic data necessary for development of IoT devices. Fifteen healthy men & women aged 20-30 were enolled, After anterior pelvic tilt & posterior pelvic tilt in sitting position were adjusted, they used a smartphone for 5 minutes & EMG signal was measured simultaneously. We used median 3 minutes of measured EMG signal. The results of this study were as follows: In the sitting position, the use of smartphone in anterior pelvic tilt had significantly lower %RVC values in both cervical erector spinae (p <.001), left upper trapezius (p <.001) & right upper trapezius (p <.002) in comparison with posterior pelvic tilt. This means that anterior pelvic tilt make vertebrae maintain normal curvature & prevent forward head posture occurred while using a smartphone. It reduces loads around neck & shoulders, so that %RVC value is significantly lowered. In the future, new posture corrected IoT devices with an aspect of pelvic tilt should be developed.

Uncertainty evaluation of the analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in hair by GC-NCI-MS/MS (GC-NCI-MS/MS를 이용한 모발 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Lee, Jae-Il;Cheong, Jae-Chul;Suh, Yong-Jun;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH), the metabolite of ${\Delta}^9$-tetrahydrocannabinol, in hair samples by using the bead-assisted liquid-liquid extraction and gas chromatography-tandem mass spectrometric (GC-NCI-MS/MS) detection. Traceability of measurement was established through the use of reference materials, calibrated volumetric tubes, volume measuring devices, and measuring instruments. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day variation was performed by using statistical analysis of several indicative factors. Measurement uncertainty associated with the analyte in real forensic hair samples were estimated using QC data. The major factor of contribution to combined standard uncertainty was inter-day repeatability, while those associated with preparation of analytical standard and also sample of weight were insignificant considering the degree of contribution. Relative uncertainty of relative extended standard uncertainty divided into the measured concentration of the analyte was 17% in a hair sample. The uncertainty of result evaluation will be invaluable to improve quality of the analysis.

A Clinical Study on Relation among Accommodative Amplitude, Response, and Facility in young adults (청.장년층에서 조절력 및 조절반응과 조절용이의 상관관계에 관한 임상적 연구)

  • Shim, Hyun-Seog;Joo, Seok-Hee;Leem, Hyun Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.115-119
    • /
    • 2009
  • Purpose: This study has been conducted to know the relation among accommodative amplitude, response, and facility. Methods: 61 subjects were students without any ocular diseases and presbyopia in a university, Korea. After far distance visual acuity was fully corrected, the amplitude was measured through Push-Up test, the response was measured through Jackson crossed cylinder ${\pm}$0.25D and the facility was measured through +2.00/ -2.00D flipper. Results: The relation among accommodative facility, response and amplitude had not indicate significant level in monocular and binocular. In binocular, 12 eyes (19.6%) had a difference in amplitude, 9 eyes (14.7%) had a difference in response, 2 eyes (3.2%) had a difference in facility from norm which would be expected from their age. 4 eyes (6.5%) had difference in both amplitude and response. 2 eye (3.2%) had difference in both amplitude and facility. In all three of the amplitude, response, facility had not difference. Conclusions: The evaluation of accommodative functions and a patients accommodative dysfunction is examined all facets of amplitude, response, and facility.

  • PDF