• Title/Summary/Keyword: 교류임피던스

Search Result 119, Processing Time 0.028 seconds

Implementation of the Blood Pressure and Blood Flow Variation Rate Detection System using Impedance Method (임피던스법을 이용한 혈압 및 혈류 변화량 검출 시스템 구현)

  • Ro, Jung-Hoon;Bae, Jin-Woo;Ye, Soo-Young;Shin, Bum-Joo;Jeon, Gye-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1926-1938
    • /
    • 2009
  • In this study, detection system of the blood flow variation rate was implemented using the variation effect of bio electric impedance at time of the blood pressure measurement by means of impedance method. The blood pressure measurement was performed by the oscillometric method. The mean arterial pressure was calculated using maximum amplitude algorithm. The systolic and diastolic pressure were estimated by establishment of the various characteristic ratio according to mean arterial pressure range. Alternative static current source and lock_in amplifier were introduced to impedance measurement. The variation of blood volume was measured using variation bio impedance according to induced cuff pressure at measuring area.

Electrical Conductivity of ${La_{2-x}}{Sr_x}{Mo_{2-y}}{Cr_y}{O_{9-\delta}}$Ionic Conductors (${La_{2-x}}{Sr_x}{Mo_{2-y}}{Cr_y}{O_{9-\delta}}$ 이온전도체의 전기전도도)

  • ;;Allan J. Jacobson
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.8
    • /
    • pp.693-697
    • /
    • 2001
  • 고상반응법으로 이론 밀도의 약 92%의 소결 밀도를 갖는 입방정계의 새로운 이온전도체 L $a_{2-x}$S $r_{x}$M $o_{2-y}$C $r_{y}$ $O_{9-{\delta}}$(x=0, 0.05, y=0, 0.1)를 제조하였다. 교류 복소임피던스는 3$50^{\circ}C$~90$0^{\circ}C$의 온도범위에서 공기중에서 측정하여, EQUIVCRT 모델링 소프트웨어로 해석하였다. 상 전이온도인 58$0^{\circ}C$ 전.후로 임피던스 스펙트럼에 큰 차이가 있었으며, 전기전도도는 L $a_2$M $o_2$ $O_{9}$ 시편의 경우 7$50^{\circ}C$에서 3$\times$$10^{-2}$ S$cm^{-1}$ /로 우수하였으며, 활성화 에너지는 고온 상 영역에서는 0.89 eV, 저온 상 영역에서는 1.12 eV이었다. 순수한 L $a_2$M $o_2$ $O_{9}$과 비교하여 Cr 치환효과는 크지 않았으나, Sr 치환 시에는 상 전이온도의 감소와 전기전도도의 증가 현상을 보였으며, 전이온도 부근에서의 전기전도도 변화 폭은 작았다.다.

  • PDF

Complex Impedance Characteristics and Electrical Conductivity of ${Nd_{1-x}}{Sr_x}{Ga_{1-x}}{Mg_x}{O_{3-\delta}$ Electrolytes (${Nd_{1-x}}{Sr_x}{Ga_{1-x}}{Mg_x}{O_{3-\delta}$ 고체전해질의 복소임피던스 특성과 전기전도도)

  • ;Allan J. Jacobson
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.4
    • /
    • pp.325-330
    • /
    • 2001
  • 고상반응법으로 이론 밀도의 약 97%의 소결 밀도를 갖는 N $d_{1-x}$S $r_{x}$G $a_{1-x}$M $g_{x}$ $O_{3{\delta}}$(x=0, 0.03, 0.07, 0.1) 고체전해질을 제조하였다. X선 회절 분석 결과, x=0.03일 때의 X선 회절도는 순수한 NdGa $O_3$와 같았으나, x=0.07, 0.1일 때에는 불순물이 나타났다. 교류 복소임피던스는 4$50^{\circ}C$~90$0^{\circ}C$의 온도 범위에서 공기 중에서 측정하였으며, 각 조성에 대하여 상호 비교 분석하기 위하여 복소비저항 스펙트럼으로 변환하여 해석하였다. 전기전도도는 N $d_{0.93}$S $r_{0.07}$G $a_{0.93}$M $g_{0.07}$ $O_{0.97}$(x=0.07) 시편이 90$0^{\circ}C$에서 6$\times$$10^{-3}$ S$cm^{-1}$ /로 가장 우수하였으며, 활성화 에너지는 저온 영역에서는 1 eV, 고온 영역에서는 0.74 eV이었다.다.

  • PDF

Effect of Total Resistance of Electrochemical Cell on Electrochemical Impedance of Reinforced Concrete Using a Three-Electrode System (3전극방식을 활용한 철근 콘크리트의 교류임피던스 측정 시 전기화학 셀저항의 영향)

  • Khan, Md. Al-Masrur;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.82-92
    • /
    • 2022
  • This study aims to investigate the effect of total electrochemical cell resistance (TECR) on electrochemical impedance (EI) measurements of reinforced concrete (RC) by electrochemical impedance spectroscopy (EIS) using a three-electrode system. A series of experimental study is performed to measure electrochemical behavior of a steel bar embedded in a concrete cube specimen, with a side length of 200 mm, in various experimental conditions. Main variables include concrete dry conditions, coupling resistance between sensing electrodes and concrete surface, and area of the counter electrode. It is demonstrated that EI values remains stable when the compliant voltage of a measuring device is sufficiently great compared to the potential drop caused by TECR of concrete specimens. It is confirmed that the effect of the coupling resistance of TECR is far more influential than other two factors (concrete dry conditions and area of the counter electrode). The results in this study can be used as a fundamental basis for development of a surface-mount sensor for corrosion monitoring of reinforced concrete structures exposed to wet-and-dry cycles under marine environment.

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

Electrochemical Impedance Study on the Rebar Corrosion in Cement Mortar Containing Chloride Ions (전기화학적 임피던스법을 이용한 염함유 시멘트 모르터내의 철근부식 연구)

  • Nam, Sang Cheal;Paik, Chi-Hum;Cho, Won Il;Cho, Byung Won;Yun, Kyung Suk;Chun, Hai Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.811-816
    • /
    • 1998
  • Rebar corrosion in cement mortar containing chloride ions was investigated by electrochemical AC impedance spectroscopy. Corrosion of mild steel bar was accelerated by an acceleration test equipment in short period. Impedance values obtained from AC-impedance method could be adapted to the proposed electrochemical equivalent circuit model and they were consistent with calculated values obtained by CNLS fitting method. The weight loss of rebar could be calculated by charge transfer resistance($R_2$) with time and it was close to real value.

  • PDF

Modeling of a Thermal Voltage Converter and Development of AC-DC Transfer Difference Calculation Program (열전형 전압변환기의 모델링 및 교류-직류 변환 차이 계산 프로그램 개발)

  • Lee Jung-Nam;Kwon Sung-Won;Jung Jae-Kap;Lee Hyo-Kyoung;Park Jong-Kweon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.5 s.96
    • /
    • pp.455-464
    • /
    • 2005
  • We have proposed a model of a thermal voltage converter(TVC) using the trans-impedance of lossy transmission line and developed a calculation program for ac-dc transfer difference of the TVC. The proposed TVC consists of a thermo-element(f) and a range resistor wire connected in series at the center of coaxial cylinder. The range resistor wire is used to extend the measurement range of the n. The calculated ac-dc transfer differences of the proposed TVC by simulation agree well with the measured values within the uncertainties. The simulated and measured values are agreed within $1{\mu}V/V$ from 40 Hz to 10kHz, within $5{\mu}V/V$ from 20kHz to 100MHz, and within $12{\mu}V/V$ from 200kHz to 1 MHz.

Magneto-impedance and Magnetic Relaxation in Electrodeposited Cu/Ni80Fe20 Core/Shell Composite Wire (전기도금 된 Cu/Ni80Fe20 코어/쉘 복합 와이어에서 자기임피던스 및 자기완화)

  • Yoon, Seok Soo;Cho, Seong Eon;Kim, Dong Young
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.10-15
    • /
    • 2015
  • The model for the magneto-impedance of composite wires composed of highly conductive nonmagnetic metal core and soft magnetic shell was derived based on the Maxwell's equations. The Cu($100{\mu}m$ diameter)/$Ni_{80}Fe_{20}$($15{\mu}m$ thickness) core/shell composite wire was fabricated by electrodeposition. The impedance spectra for the $Cu/Ni_{80}Fe_{20}$ core/shell composite wire were measured in the frequency range of 10 kHz~10 MHz under longitudinal dc magnetic field in 0 Oe~200 Oe. The spectra of complex permeability in circumferential direction were extracted from the impedance spectra by using the derived model. The extracted spectra of complex permeability showed relaxation-type dispersion which is well curve-fitted with Debye equation with single relaxation frequency. By analyzing the magnetic field dependence of the complex permeability spectra, it has been verified that the composite wire has magnetic anisotropy in longitudinal direction and the origin of the single relaxation process is the magnetization rotation in circumferential direction.

Design of an Active Shaft Grounding System for the Elimination of Alternating Electromagnetic Field in Vessel (선체 교류 전자장 제거를 위한 능동 축 접지 시스템 설계)

  • Kim, Tae-kue;Ahn, Ho-kyun;Yoon, Tae-sung;Park, Seung-kyu;Kwak, Gun-pyong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1515-1524
    • /
    • 2015
  • Recently, for the purpose of preventing the corrosion of a vessel, the electrical corrosion protection device that prevents the corrosions of the hull and the propeller is widely used. However, the electrical corrosion protection method artificially emits the current into the seawater around the hull using the power supply in order to make the hull and propeller be in the state of not being corrosion, so that electromagnetic field is generated outside the hull by the current emitted into the seawater. In this paper, the static and alternating constituents of the electromagnetic field generated in underwater outside the hull are analyzed and a countermeasure is investigated to reduce the strength of the electromagnetic field. In conventional shaft grounding system, the shaft potential is maintained above at least 100mV and the alternating current component constitutes more than 10% of the total current. However, in this paper, a control system was designed in order that the alternating current component and the shaft potential which generate electromagnetic field are maintained within 1% and 2mV respectively, and the performance was verified by simulation.

Characteristics of Electrode Potential and AC Impendance of Perchlorate Ion-Selective Electrodes Based on Quaternary Phosphonium Salts in PVC Membranes (제4급 인산염을 이용한 과염소산 이온선택성 PVC막 전극의 전극전위와 AC 임피던스 특성)

  • 안형환
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.230-239
    • /
    • 1999
  • Perchlorate ion-selective electrodes in PVC membranes that respond linearly to concentration 106 M were developed by incorporating the quaternary phosphonium salts as a canier. The effects of the chemical structure, the contents of canier, the kind of plasticizer and the membrane thickness on electrode characteristics such as the electrode slope, the linear respone range and the detection limit were studied. With this results, the detectable pH range, selectivity coefficients and AC impedance characteristics were compared and investigated. The perchlorate ion substituents of the quaternary phosphonium salts like tetraoctylphosphonium perchlorate (TOPP) , tetraphenylphosphonium perchlorate(TPPP), and tetrabutylphosphonium perchlorate(TBPP) as a canier were used. The electrode characteristics were better in the ascending order of TBPP < TPPP < TOPP, with the increase of carbon chain length of the alkyl group. Dioctylsebacate(OOS) was best as a plasticizer, the canier contents were better with 11.76 wt% and the optimum membrane thickness was 0.19 mm. Under the above condition, the electrode slope was 56.58 mV/$^P{ClO}_4$,the linear response range was $10^{-1}$\times$10^{-6}$ M, the detection limit was 9.66 x $10^{-7}$ M. The performance of electrode was better than Orion electrode. The electrode potential was stable within the pH range from 3 to 11. The order of the selectivity coefficients for the perchlorate ion was sol < F < Br < 1. With the result of impedance spectrum, it was found that the equivalent circuit for the electrode could be expressed by a series combination of solution resistance, parallel circuit consisting of the double layer capacitance and bulk resistance and Warburg impedance. And solution resistance was almost not appeared and Warburg impedance was highly appeared by diffusion. Then Warburg coefficient was 1.32$\times$$10^74 $\Omega$ $\cdot$ ${cm}^2/s^{1/2}$.

  • PDF