• 제목/요약/키워드: 교류발전기

검색결과 78건 처리시간 0.02초

교류 발전기의 고장 검출 알고리즘에 관한 비교 연구 (A Comparative Study on Fault Detection Algorithm of AC Generator)

  • 박철원;신광철;신명철
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.102-108
    • /
    • 2008
  • AC generator plays an important role of power system. The large AC generator fault may lead to large impacts or perturbations in power system. And then the protection of a generator has very important role in maintaining stability in a power system. In present, the DFT(discrete Fourier transform) based RDR(ratio differential relay) had been widely applied to a internal fault of a generator stator winding. But DFT has a serious drawback. In the course of transforming a target signal to frequency domain, time information is lost. DWT uses a time-scale region. This paper proposes an advanced fault detection algorithm using DWT(discrete Wavelet transform) to enhance the drawback of conventional DFT based relaying. To evaluate the performance of the proposed relaying, we used the test data which were sampled with 720 [Hz] per cycle and obtained from ATP(alternative transient program) simulation. And we made a comparative study of conventional DFT based RDR and the proposed relaying.

인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발 (Development of generator excitation system with main/standby controller in Inchun thermal power plant #4)

  • 류호선;김수열;김장목;임익헌
    • 전력전자학회논문지
    • /
    • 제4권6호
    • /
    • pp.507-514
    • /
    • 1999
  • 한국전력에서는 인천화력 4호기 수명연장의 일환으로 여자시스템 교체가 이루어졌다. 기존의 회전형 여자 시스템은 발전기축에 부여자기와 교류여자기가 부착되어 회전하는 형태로 과거 스위칭소자 용량의 한계를 극복하기 위하여 설계된 시스템으로 전력연구원에는 회전형 여자시스템을 새롭게 개발된 아날로그와 디지털의 하이브리드 제어기와 대용량 사이리스터 제어정류기를 가지고 잇는 정지형 이중화 여자시스템으로 교체하였다. 설비의 신뢰성을 높이기 위하여 정지형 여자시스템의 상태를 순시 감시하기 위한 데이터 취득 시스템이 설치 되었고 위상제어정류기는 운전시 1대가 고장이 발생하더라도 발전기의 전부하 능력을 유지하기 위하여 3대가 병렬로 운전되는 N+1 방식을 채택하였다. 시스템의 신뢰성 시험은 성능평가를 위한 시운전시에 검증되었으며 성공적으로 운전중에 있다.

  • PDF

교류 발전기 고정자 사고 검출을 위한 최적 마더 웨이브릿의 선정 (A Selection of an Optimal Mother Wavelet for Stator Fault Detection of AC Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.377-382
    • /
    • 2008
  • For stator winding protection of AC generator, KCL(Kirchhoff's Current Law) is widely applied. Actually a CRDR(Current Ratio Differential Relay) based on DFT(Discrete Fourier Transform) has been used for protecting generator. It has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. Wavelets techniques are proposed for the analysis of power system transients. This paper introduces an algorithm to choose a suitable Mother Wave1et for generator stator fault detection. For optimal selection, we analyzed db(Daubechies), sym(Symlets), and coif(Coiflects) of Mother Wavelet. And we compared with performance of the choice algorithm using detail coefficients energy and RMS(root mean square) error. It can be improved the reliability of the conventional DFT based CRDR. The feasibility and effectiveness of the proposed scheme is proved with simulation using collected data obtained from ATP (Alternative Transient Program) package.

보정된 2차원 모델에 의한 초전도 교류 발전기의 과도특성 해석 (Analysis of Transient Characteristics in Superconducting AC Generator Using the Compensated 2-D Model)

  • 이형우;전연도;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.103-105
    • /
    • 1998
  • This paper presents the compensated 2-D magnetic fields analysis of superconducting AC generator(SCG) by using efficient 2-D model. 3-D analysis is necessary for the accurate analysis because SCG has a large leakage flux owing to the air cored winding and end ring structure. However, in 3-D FEM, considering the movement of rotor is difficult, so efficient 2-D model which can compensate the leakage flux has been proposed and the movement of rotor is easily considered. The characteristics in transient state of SCG and the prime role of damper also have been evaluated.

  • PDF

원전 비상전원 설계를 위한 납축전지 및 리튬계열전지 전기적 특성 비교 (Comparison of electrical characteristic between Lead-Acid Battery and Lithium-based Battery for Designing in NPPs)

  • 박성윤;김건우;김종훈;박성백
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.119-120
    • /
    • 2018
  • 국내 원자력 발전소의 비상전원공급을 위하여 대체교류디젤 발전기와 납축전지를 사용하고 있다. 납축전지는 온도, 방전 전류, 수명 및 안정성 등에서 리튬계열전지와 비교되고 있으며, 전기적 특성이 우수하고 안정성이 높은 리튬계열전지의 사용이 고려되고 있다. 본 논문은 원전의 비상전원 설계를 위하여 납축전지와 리튬계열전지의 전기적 특성을 비교 분석하였다.

  • PDF

계통연계 태양광발전시스템과 회전계자형 동기발전기의 병렬운전 특성 (Parallel Operation Characteristics of Utility Interactive Photovoltaic System and Revolving Field Type Synchronous Generator)

  • 류연수;유왕진;이철규;문종범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.43-48
    • /
    • 2008
  • Through simulations and field experiment on A.C. parallel operation of both Utility Interactive Photovoltaic System and Diesel Engine Revolving Field Type Synchronous Generator, following factors have been found. First, the inverter should be operated in three modes of frequency(mode.1: ${\pm}$0.3Hz, mode.2: ${\pm}$1Hz, mode.3: ${\pm}$2Hz) as default, considering properties of operating Synchronous Generator. Second, as a result of supplying 13.5kW of residual power, it has been found that Synchronous Generator takes the power input only as reactive power, because it was electrically stable with frequency of 60.14Hz and high voltage of 222.3V even when power factor was -0.94. Besides, it was mechanically stable, too, because the quake, noise, and temperature of Synchronous Generator in this case were 7.5mm/s, 97dB, and $6^{\circ}C$ respectively, which were lower than normal load connection of 145.6kW; 11.03mm/s. Thus, load share of Revolving Field Type Synchronous Generator reduces according to the supply of Photovoltaic System to the load power. In this experiment, 200kW of Synchronous Generator and 40kW of Photovoltaic System were operated in parallel. The load share was 20% in maximum. and 11.1lit/hr of fuel was saved.

  • PDF

분리축방식 터보축 엔진의 정상상태 모사 및 실험연구 (A Steady-State Simulation and Experimental Study of Turboshaft Engine with Free Power Turbine)

  • 공창덕;기자영;고광웅
    • 한국추진공학회지
    • /
    • 제1권2호
    • /
    • pp.84-90
    • /
    • 1997
  • 다목적으로 활용할 수 있는 분리축방식의 터보축 엔진 개발을 위한 정상상태 해석 프로그램의 개발과 함께 동일한 형식의 가스터빈엔진 시험장치를 이용한 실험을 통해 프로그램의 해석결과와 비교, 그 타당성을 입증하였다. 실험에 이용된 시험장치는 1단 원심형 압축기, 인통형 연소기, 1단 원심형 압축기 터어빈 및 동력 터어빈으로 구성되어 있으며 출력은 3상 교류발전기를 통해 획득된다. 해석에 사용된 주요 구성품의 성능곡선은 시험장치 제작자로부터 획득된 자료를 이용하였으며, 경우에 따라 시험장치를 이용한 실험을 통하여 보정하였다. 시험장치를 이용한 실험결과를 프로그램 해석결과와 비교한 결과, 시험장치의 운용제한에 의해 실제 작동영역이 제한되기는 했으나, 압력비, 출력 등 주요 변수들에서 6% 미만의 오차를 보였다.

  • PDF

전기도금 방법으로 제작한 코일을 이용한 초소형 발전기의 특성분석 (Characterization of a Micro Power Generator using a Fabricated Electroplated Coil)

  • 이동호;김성일;김영환;김용태;박민철;이창우;백창욱
    • 마이크로전자및패키징학회지
    • /
    • 제13권3호
    • /
    • pp.9-12
    • /
    • 2006
  • 전기도금 방법으로 유리기판 위에 제작한 코일과 영구자석을 이용하여 초소형발전기를 제작하였다. 여러 크기의 코일 구조를 설계한 마스크를 제작하고, 이를 이용하여 MEMS 코일을 제작하였다. 그 중 두께가 $7{\mu}m$ 선폭이 $20{\mu}m$ 길이가 1.6 m인 코일을 선택하여 실험하였다. 광학현미경과 SEM을 사용하여 제작된 코일의 구조를 분석하였다. 또한 모터의 회전운동을 진동운동과 유사한 선형운동으로 변환하는 진동발생시스템을 제작하였고, 자석과 코일을 진동발생장치에 설치하고 진동을 발생시키면 교류 전압이 발생한다. 0.5Hz에서 8Hz까지 진동주파수를 변화시켜 특성을 측정하였다. 발생된 전압은 3Hz에서 106mV가 발생하였고, 6Hz에서 198mV가 발생하였다. 본 연구의 목적은 쓸모없이 버려지는 진동에너지를 유용한 전기에너지로 변환하는 초소형발전기 소자를 제작하는 것이다.

  • PDF

전기자동차용 전동기/제어기의 시험 방법 (Test method for Motor/controller for Electric Vehicle)

  • 오성철
    • 전력전자학회논문지
    • /
    • 제8권4호
    • /
    • pp.328-335
    • /
    • 2003
  • 본 논문에서는 전기자동차용 전동기/제어기를 시험하기 위한 절차를 제시하였다. 현재 전기자동차용 전동기/제어기의 시험에 관한 국제 규격은 주로 안전 운전을 위한 최소 기준치를 정의하고 있지만 상세한 시험 방법에 대해서는 기술하고 있지 않다. 시험 항목 및 방법을 개발하기 위하여 기존의 선진국 규격에 대하여 전문가들의 의견을 바탕으로 보완 작업을 수행하였다. 개발된 규격에 따라 전동기/제어기의 시험 방법을 제시하였으며 다양한 부하 장치를 사용할 경우의 시험 방법을 제시하였다. 시험 절차는 주로 전동기 제어기 조합시험에 주안점을 두었으며 부하 장치로는 전동기-발전기, 와전류형 엔진 다이나모, 교류 다이나모 등을 사용하였으며 전동기/제어기를 차량에 탑재하지 않은 상태에서 전동기/제어기의 실제 주행모드 운전 특성을 시험하기 위한 방법을 제시하였다.

고효율 신형 정류시스템에 대한 고찰 (A study on the new high efficiency rectifier system)

  • 김규홍;정재훈;조만현;안치홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3172-3174
    • /
    • 1999
  • 교환기나 전송장치 등 각종 통신설비에 전원을 공급하기 위해서 정류기, 축전지 및 발전기 등의 전원설비가 사용되고 있다. 이들 중에서도 정류기는 통신설비에 직류전원을 공급하기 때문에 다른 전원설비 보 다도 신뢰성 및 안정성이 확보된 장치로 인식되어 왔다. 그러나 현재 사내전화국에 설치 운용중인 정류기는 교환 기별로 종류가 다양하여 유지보수에 어려움이 내재하고 있을 뿐만 아니라 통신망의 광대역화, 대용량화에 대처가 곤란하며 정류기를 전력실 또는 통신실에 집중해서 설치 운용하는 집중공급방식으로는 축전지의 만충전이 곤란하다. 또한 현재의 이러한 급전방식은 통신장치의 광대역화, 고도화 등 통신망의 급격한 발전과 함께 다음과 같은 문제점이 대두되고 있다. 첫째, 전력실에서 총괄하여 교류전력을 직류48V로 변환해서 급전하기 때문에 급전전류가 크게되고, 또한 전력실에서 통신실까지의 급전손실이 크다 둘째, 통신설비의 증감에 따른 전원설비의 증감이 어렵기 때문에 설비 가동율이 나쁘다 셋째, 전원설비의 고장에 의한 전화국 전체설비에 심각한 영향을 미칠수 있다 이러한 문제점을 해소하기 위하여 집중 및 분산급전방식으로 운용이 가능하며, 또한 모든 전원설비를 감시/제어하는 전원 집중관리 시스템과의 인터페이스 등이 가능한 정류시스템을 1997년부터 개발하였다. 본고에서는 신형 정류기와 기존의 정류기와의 성능 및 특성에 대해 비교하였고, 특히 경제성측면과 설치상련에 대해 비교분석 하였다. 또한 집중급전방식과 분산급전방식의 특성에 대해서도 서술하였다.

  • PDF