• Title/Summary/Keyword: 교량구조물

Search Result 798, Processing Time 0.026 seconds

A Basic Study on Vehicle Load Analyzing System for Embedded Road (임베디드 도로를 위한 차량하중 분석시스템 기초연구)

  • Jo, Byung-Wan;Yoon, Kwang-Won;Park, Jung-Hoon;Kim, Heoun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.127-132
    • /
    • 2011
  • Load managing method on road became necessary since overloaded vehicles occur damage on road facilities and existing systems for preventing this damage still show many problems. Accordingly, efficient managing system for preventing overloaded vehicles could be organized by using the road itself as a scale by applying genetic algorithm to analyze the load and the drive information of vehicles. First of all, accurate analysis of load using the behavior of road itself is needed for solving illegal axle manipulation problems of overloaded vehicles and for installing intelligent embedded load analyzing system. Accordingly in this study, to use the behavior of road, the transformation was measured by installing underground box type indoor model and indoor experiment was held using genetic algorithm and 10% error were checked.

A Study of the Advanced Composite Material Slab for Light Weight of Tall Building (초고층빌딩 경량화를 위한 복합신소재 슬래브에 관한 연구)

  • Han, Bong-Koo
    • Composites Research
    • /
    • v.27 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • For each construction material used, there is certain theoretical limit in sizes. For tall building construction, the reduction in slab weight is the first step to take in order to break such size limits. In this paper, the feasibility of such objective is proven and given by numerical analysis result. For a typical building slab, both concrete and advanced composite sandwich panels are considered. The concrete slab is treated as a special orthotropic plate to obtain more accurate result. For each panel, the deflection under the dead and live loads is compared, since both tensile and compressive strengths of the composites are far more higher than those of concrete. All types of sandwich panels considered, except one case, have self-weights less than one tenth of that of the reinforced concrete slab, with deflections less than that of the reinforced concrete slab.

Selective Histogram Matching of Multi-temporal High Resolution Satellite Images Considering Shadow Effects in Urban Area (도심지역의 그림자 영향을 고려한 다시기 고해상도 위성영상의 선택적 히스토그램 매칭)

  • Yeom, Jun-Ho;Kim, Yong-Il
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.2
    • /
    • pp.47-54
    • /
    • 2012
  • Additional high resolution satellite images, other period or site, are essential for efficient city modeling and analysis. However, the same ground objects have a radiometric inconsistency in different satellite images and it debase the quality of image processing and analysis. Moreover, in an urban area, buildings, trees, bridges, and other artificial objects cause shadow effects, which lower the performance of relative radiometric normalization. Therefore, in this study, we exclude shadow areas and suggest the selective histogram matching methods for image based application without supplementary digital elevation model or geometric informations of sun and sensor. We extract the shadow objects first using adjacency informations with the building edge buffer and spatial and spectral attributes derived from the image segmentation. And, Outlier objects like a asphalt roads are removed. Finally, selective histogram matching is performed from the shadow masked multi-temporal Quickbird-2 images.

LoRa LPWAN-based Wireless Measurement Sensor Installation and Maintenance Plan (LoRa LPWAN 기반의 무선 계측센서 설치 및 유지관리 방안)

  • Kim, Jong-Hoon;Park, Won-Joo;Park Sang-Hyun, Jin-Oh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • Social infrastructure facilities that have been under construction since the country's high-growth period are undergoing rapid aging, and, thus, safety assessments of large structures such as bridge tunnels, which can be directly linked to large-scale casualties in the event of an accident, are necessary. It is difficult to construct economical and efficient wireless smart sensor networks that improve structural health monitoring (SHM) because the existing wire sensors have a short signal reach. However, low-power wide-area networks (LPWANs) are becoming popular within the Internet of Things, and enable economical and efficient SHM. In this study, the technology trends of a wireless measuring sensor based on LoRa LPWANs were investigated, and an installation and maintenance plan for this type of sensor is proposed.

A Design of Transducer Interface Protocol for Context-aware Middleware (상황인식 미들웨어를 위한 트랜스듀서 인터페이스 프로토콜 설계)

  • Jang, Dong-Wook;Sohn, Surg-Won;Han, Kwang-Rok;Sun, Bok-Keun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.9
    • /
    • pp.45-55
    • /
    • 2011
  • Context awareness technologies are based on efficient sharing of environment information of ubiquitous sensors in everyday life, and users require this awareness technologies to get quality of services. However, the application has been restricted due to its varieties of sensors and many different methods of communications. Therefore, IEEE 1451 standard has been published to interface between sensors and network layer. But it does not connect to a middleware because IEEE 1451 is for transducer standards. This paper presents a transducer and application interface protocol which connect to the context-aware middleware by defining a protocol to obtain context information using XML. We have implemented a bridge health monitoring system and railroad monitoring system in which different sensors and users' application are used to prove the efficacy of proposed interface protocols.

Comparison of Modeling Methods of a Pile Foundation in Seismic Analysis of Bridge Piers (교각의 내진설계를 위한 말뚝기초의 모델링 기법 비교)

  • 김나엽;김성렬;전덕찬;김명모
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.6
    • /
    • pp.25-32
    • /
    • 2002
  • In the seismic designing of bridges, the pile foundation of bridge piers generally have been modeled to have a fixed end for its convenience and conservative designing. The fixed-end assumption, however, produces very conservative results in terms of the pier forces. Therefore, many other design methods are evolved to consider the flexibility of the pile foundation. In this study, the response spectrum analysis was performed for a bridge pier having a pile foundation. The shear force, moment, and displacement, which occurred at the pier column under an earthquake loading, were compared to analyze the effects of the modeling method, soil condition and the input earthquake response spectrum. In most cases, the fixed-end model gives larger design forces than flexible foundation models. However, when a long period earthquake is applied to the bridge pier on a soft clay foundation, it is found that the flexible foundation models give larger design forces than the fixed-end model. In the end, the reliability of several flexible foundation models was verified by comparing their results with those of a numerical analysis that considers the soil-structure interaction phenomenon in a rigorous manner.

The Effect of Neglecting the Longitudinal Moment Terms in Analyzing Laminates with Increasing Aspect Ratio (적층판 해석시 형상비 증가에 따른 종방향 모멘트의 무시효과)

  • Han, Bong Koo;Kim, Duk Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.53-60
    • /
    • 2001
  • Theories for advanced composite structures are too difficult for such design engineers for construction and some simple but accurate enough methods are necessary. The senior author has reported that some laminate orientations have decreasing values of $D_{16}$, $B_{16}$, $D_{26}$ and $B_{26}$ stiffnesses as the ply number increases. For such plates the fiber orientations given above behave as specially orthotropic plates and simple formulas developed by the senior author. Most of the bidge and building slabs on girders have large aspect ratios For such cases frurther simplification is possible by neglecting the effect of the longitudinal moment terms(Mx) on the relevant partial differential equationsof equilibrium In this paper, the result of the study on the subject problem is presented.

  • PDF

Changes in Corrosion Progress and Ultimate load of Tendon Under 20% and 40% of Ultimate Loading Conditions (파괴하중의 20% 및 40% 인장조건에서 텐던 부식 진행 및 파괴하중 변화)

  • Ryu, Hwa-Sung;An, Gi Hong;Hwang, Chul-Sung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.47-52
    • /
    • 2017
  • PSC (Prestressed Concrete) structures have been used widely for its engineering advantage with using total concrete area as effective compressive section. However tendon inside is exposed to such a high tensile stress that and more attentions should be paid for corrosion control. This work is for changing corrosion current and ultimate strength in tendon with increasing prestressing force in a constant corrosive condition. With increasing prestressing force, corrosion current, corrosion amount, and ultimate load are changed linearly. When prestressing force increases from 20.0 % to 40.0 %, corrosion current increases to 124.4 % and 168.0 % and ultimate load decreases to 87.8 % and 78.4 %, respectively. With inducing constant electrical potential, increasing corrosion current and reduction of strength are evaluated to be linearly related with increasing prestressing load.

Experimental Analysis of Vibration Transfer Characteristics of an Elevated Railroad Station (철도 선하역사 진동 전달 특성의 실험적 분석)

  • Choi, Sanghyun;Yoo, Yong;Kim, Jinho;Kwon, Segon
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.89-96
    • /
    • 2015
  • To reduce noise inside an elevated railroad station, the vibration of the station structure should be lowered, and to establish more effective anti-vibration measures it is required that, reflecting the track-bridge-structure interaction, the transfer characteristics of vibration induced by a train is well identified. In this paper, the current status of domestic railroad stations is classified, and the vibration transfer characteristics is analyzed via measurement data from representative elevated stations. From the analysis results on the measurement data, in transferring vibration from the track to the structure, remarkable vibration reduction in higher frequency range is observed, and, in some stations, amplified response characteristics in lower frequency range is identified. Also, for stations with floating track system or TPS type, relatively greater reduction in transferred vibration is observed.

A Study on Fatigue Crack at Coped Stringers of the Plate Girder Subway-Bridge (플레이트거더 지하철교량 세로보의 피로 균열에 관한 연구)

  • Jo, Jae Byung
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.713-724
    • /
    • 2004
  • A fatigue crack found at the coped stringer of the old dismantled Dangsan Subway Bridge was numerically simulated. A model of a single span of the plate girder bridge with its beam elements was created and analyzed in order to obtain the nominal stress history caused by trains. A detailed FEM analysis of the coped stringer was conducted using a shell element model. A fracture mechanical model was used to estimate crack propagation. The stress intensity factors were calculated using the J-Integral method. The simulation with some reasonable assumptions showed that the calculated crack lengths were comparable to those found on the site.