• Title/Summary/Keyword: 광 상관

Search Result 671, Processing Time 0.032 seconds

Anomaly Detection from Hyperspectral Imagery using Transform-based Feature Selection and Local Spatial Auto-correlation Index (자료 변환 기반 특징 선택과 국소적 자기상관 지수를 이용한 초분광 영상의 이상값 탐지)

  • Park, No-Wook;Yoo, Hee-Young;Shin, Jung-Il;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.4
    • /
    • pp.357-367
    • /
    • 2012
  • This paper presents a two-stage methodology for anomaly detection from hyperspectral imagery that consists of transform-based feature extraction and selection, and computation of a local spatial auto-correlation statistic. First, principal component transform and 3D wavelet transform are applied to reduce redundant spectral information from hyperspectral imagery. Then feature selection based on global skewness and the portion of highly skewed sub-areas is followed to find optimal features for anomaly detection. Finally, a local indicator of spatial association (LISA) statistic is computed to account for both spectral and spatial information unlike traditional anomaly detection methodology based only on spectral information. An experiment using airborne CASI imagery is carried out to illustrate the applicability of the proposed anomaly detection methodology. From the experiments, anomaly detection based on the LISA statistic linked with the selection of optimal features outperformed both the traditional RX detector which uses only spectral information, and the case using major principal components with large eigen-values. The combination of low- and high-frequency components by 3D wavelet transform showed the best detection capability, compared with the case using optimal features selected from principal components.

Diurnal and Seasonal Variation of Chlorophyll Fluorescence from Korean Fir Plants on Mt. Halla (한라산 구상나무 잎의 엽록소형광의 일변화와 계절적 변화)

  • 오순자;고정군;김응식;오문유;고석찬
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.1
    • /
    • pp.43-48
    • /
    • 2001
  • Chlorophyll fluorescence of needles of Korean fir (Abies koreana) plants and environmental factors of their natural habitat were investigated in order to obtain the information for environmental adaptation and conservation of Korean fir plants. The photochemical efficiency of photosystem II, Fv/Fm, of Korean fir needles was significantly low (0.19-0.36) in the winter, whereas it was high (0.8-0.86) in the summer. The Fv/Fm value of the winter was slightly higher at mid-day than at dawn, suggesting that mid-day environmental conditions of the winter were favorable on needles of Korean fir plants. In contrast, the mid-day Fv/Fm value of the summer maintained high (around 0.8). It indicates that mid-day environmental conditions of the summer did not induce photodamage, although it caused a slight decrease in the Fv/Fm values. The non-photochemical fluorescence quenching (NPQ) of Korean fir needles was very low (0-0.01) all through the day in the winter. However, it was high (0.76) at mid-day in the summer. These results suggest that Korean fir plants have a system for the protection of PS II from mid-day environmental stresses of the summer. In the winter, the Fv/Fm values were positively correlated with temperature, light intensity and relative humidity, although NPQ values showed no correlation with any of them. In the summer, the Fv/Fm values were positively correlated with relative humidity but negatively correlated with temperature and light intensity. These results indicate that increase of tempera-ture, light intensity and relative humidity lead to promotion of the photochemical efficiency in the winter and high temperature and light intensity may cause photoinhibition in the summer.

  • PDF

In Vitro Effect on Light Qualities and Lighting Types Provided by Light-Emitting Diodes (LEDs) for the Mycelia Growth of Soil-Borne Fungal Pathogens in Apple (기내에서 Light-Emitting Diodes(LEDs)를 이용한 광질과 광조사 방법이 사과 토양병원균의 균사생장에 미치는 영향)

  • Lee, Sung-Hee;Kwon, Yeuseok;Shin, Hyunman;Chang, Whobong;Nam, Sang-Yeong;Hong, Eui Yon;Cha, Jae-Soon;Heo, Jeong Wook
    • Research in Plant Disease
    • /
    • v.22 no.2
    • /
    • pp.100-106
    • /
    • 2016
  • We have studied the mycelia growth of four soil-borne fungal pathogens under light qualities and two lighting types (continuous and intermittent) provided by light-emitting diodes (LEDs). As a result, each mycelia growth on Phytophthora cactorum KACC40166, Athelia rolfsii KACC40170, and Helicobasidium mompa KACC40836 strain showed the similar growth rates within 10% or less difference among treatments compared to dark control, regardless of lighting types. However, the mycelia growth on Rosellinia necatrix KACC40168 strain was significantly suppressed by blue, blue+green and blue+red LED as well as fluorescent lamp compared to a dark control, in common with lighting types. The melanin pigment on R. necatrix KACC40168 strain showed relatively to induce more strongly under green LED and fluorescent lamp, whereas no induction under red LED and a control, regardless of lighting types. Thus, the hypha width on R. necatrix KACC40168 was significantly thinned by blue and blue+green LED compared to a control, in common with lighting types.

Evaluations of the Accuracy and Reliability of Measurements Made on White Light Scanner-based Dental Digital Models (백색광 스캐너로 채득된 치과용 디지털모형의 정확도와 신뢰도 평가)

  • Kim, Ki-Baek;Kim, Jae-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.357-364
    • /
    • 2012
  • Dental scanner-based dental digital models have been developed that have the potential to replace conventional stone model. The aim of this study was examine the accuracy and reliability of measurements made on digital models. A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the white light scanner(Identica, korea). One examiner individually measured 6 parameters on the conventional model and the digital models on two occasions. The student's t-test for paired samples and intra-class correlation coefficient(ICC) were used for statistical analysis. At the intra-examiner reliability of measurement, ICC at the stone and digital models were 0.75 and 0.87. The mean difference between measurements made directly on the stone models and those made on the digital models was 0.11-0.23mm, and was statistically significant(P<0.05). These in vitro studies show that accuracy of the digital model is similar to that of the stone model. These results will have to be confirmed in further clinical studies.

A Study on the Reception Sensitivity of the Optical Receiver with the Order Change of the Optical Filter in Optical Preamplifier System (광 전치 증폭시스템에서 광필터의 차수변화에 따른 광수신기의 수신감도에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.218-223
    • /
    • 2016
  • This study examined the order of the Butterworth filter for the correlation on the sensitivity of the receiver in the receiver of an optical system. In the general case, the sensitivity of the receiver is increased if the order of the filter was increased more. This is because increasing the order of the filter response of the normalized frequency of the filter is similar to the rectangular wave. For that reason, the method used to increase the order of the filter increases the sensitivity of the receiver. On the other hand, a method of increasing the order of the filter and makes the system complicated increases the cost of the system. This study examined the correlation between the order of the sensitivity of the receiver filter and to configure the system by simply looking for ways to reduce the cost of the system. The simulation results showed that increasing the order of the filter resulted in a receiver that can determine if the sensitivity is raised. In addition, the order of the Butterworth filter range that does not reduce the sensitivity of the receiver was 2. Therefore, it will be possible to implement an inexpensive optical system of the receiver using the data from this study.

Characteristics of Photosynthesis and Dry Matter Production of Liriope platyphylla $W_{ANG}\;et\;T_{ANG}$ (차광처리에 의한 맥문동의 광합성 및 물질 생산 특성)

  • Won, Jun-Yeon;Lee, Chung-Yeol
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.2
    • /
    • pp.82-87
    • /
    • 2002
  • This study was conducted to investigate the influence of shading treatment on the photosynthetic rate, transpiration rate, stomatal conductance and its any correlations in Liriope platyphylla $W_{ANG}\;et\;T_{ANG}$. Followings were achieved as a conclusion. The net photosynthetic rate was increased as the PAR was increased and reached maximum at the $700-1000{\mu}mol/m^2/s$ of PAR in all of leaves, also this treatment caused a higher net photosynthetic rate in comparison with control. It shows the tendency of increasing stomatal conductance caused by the increment of PAR. The diurnal changes of photosynthesis, transpiration rate and stomatal conductance were increased as the PAR was increased in the morning, but they indicated a decreased tendency in broad day. The relationship between net photosynthetic rate and stomatal conductance is well fit by the first regression linear equation. However, the values obtained from the linear equation have the different, respectively, and have highly significance. From the above results, net photosynthetic rate of shading treatment is higher than control in the same stomatal conductance. Different first regression linear equation were obtained between the transpiration rate and stomatal conductance, photosynthesis and stomatal conductance in during the control and shading treatment, too.

Measuring Leaf Areas with a Structured-Light 3D Scanner (3차원 구조광 스캐너를 이용한 식물의 잎 면적 측정 방법)

  • Nam, Kyong-Hee;Ko, Eun Mi;Mun, Saeromi;Kim, Chang-Gi
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.3
    • /
    • pp.232-238
    • /
    • 2014
  • We have developed a non-destructive, touch-free method for estimating leaf areas with a structured-light three-dimensional (3D) scanner. When the surfaces of soybean leaves were analyzed with both the 3D scanner and a leaf area meter, the results were linearly related ($R^2=0.90$). The strong correlation ($R^2=0.98$) was calculated between shoot fresh weights and leaf areas when the scanner was employed during growth stages V1 to V4. We also found that leaf areas measured by the scanner could be used to detect changes in growth responses to abiotic stress. Whereas under control conditions the areas increased over time, salt and drought treatments were associated with reductions in those values after 14 d and 12 d, respectively. Based on our findings, we propose that a structured-light 3D scanner can be used to obtain reliable estimates of leaf area and plant biomass.

DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT (광중합기를 이용한 광학적 치아우식활성도 검사법)

  • Lee, Nan-Young;Kim, Mi-Ra;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.671-679
    • /
    • 2004
  • The purpose of this study was to develop a practical caries activity test by fluorescence using laser, plasma light and halogen light. The subjects of study were 45 children of 7-8 years old Argon laser, plasma light and halogen light were irradiated to buccal or labial surface of all teeth. Fluorescence of initial carious lesion from teeth was observed through barrier filter and the number of teeth showing lesion was counted. Visual examination for the dDfFtT, mutans streptococci screening test and Lactobacilli colony counting were also done. Data analysis was accomplished by Axelsson's method. The result from the present study can be summarized as follows. 1. Laser, plasma light and halogen light could detect the initial carious lesions better than visual examination(p<0.05). 2. There was positive correlation between laser(r=0.42), plasma light(r=0.41), halogen light(r=0.39) and dBfFtT rate(p<0.01). 3. The specificity sensitivity and predictive value was showed highest value in laser, but was showed favorable value in plasma light and halogen light. In regard to above results, laser, plasma light and halogen light all considered to be reliable method for determining individual caries activity. And they were also considered to be practical method because it would be simple, inexpensive, and time saving method.

  • PDF

A Study on Photovoltaic Panel Monitoring Using Sentinel-1 InSAR Coherence (Sentinel-1 InSAR Coherence를 이용한 태양광전지 패널 모니터링 효율화 연구)

  • Yoon, Donghyeon;Lee, Moungjin;Lee, Seungkuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.2
    • /
    • pp.233-243
    • /
    • 2021
  • Photovoltaic panels are hazardous electronic waste that has heavy metal as one of the hazardous components. Each year, hazardous electronic waste is increasing worldwide and every heavy rainfall exposes the photovoltaic panel to become the source of heavy metal soil contamination. the development needs a monitoring technology for this hazardous exposure. this research use relationships between SAR temporal baseline and coherence of Sentinel-1 satellite to detected photovoltaic panel. Also, the photovoltaic plant detection tested using the difference between that photovoltaic panel and the other difference surface of coherence. The author tested the photovoltaic panel and its environment to calculate differences in coherence relationships. As a result of the experiment, the coherence of the photovoltaic panel, which is assumed to be a permanent scatterer, shows a bias that is biased toward a median value of 0.53 with a distribution of 0.50 to 0.65. Therefore, further research is needed to improve errors that may occur during processing. Additionally, the author found that the change detection using a temporal baseline is possible as the rate of reduction of coherence of photovoltaic panels differs from those of artificial objects such as buildings. This result could be an efficient way to continuously monitor regardless of weather conditions, which was a limitation of the existing optical satellite image-based photovoltaic panel detection research and to understand the spatial distribution in situations such as photovoltaic panel loss.

Trial to Identify Irradiated Corn Powder by Viscometric and Pulsed Photostimulated Luminescence (PPSL) Methods

  • Yi, Sang-Duk;Chang, Kyu-Seob;Yang, Jae-Seung
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.1
    • /
    • pp.82-87
    • /
    • 2001
  • A study was performed to establish detection methods by viscometric and pulsed photostimulated luminescence (PPSL) methods for irradiated com powder. Viscosity was determined using a Brookfield DV-rotation viscometer at 3$0^{\circ}C$ and operated at 30, 60, 90, 120, 150, 180, and 210 rpm. All irradiated samples showed a decrease in Viscosity with increasing stirring speeds (rpm) and irradiation doses. Treatments at 1~3 kGy significantly decreased the viscosity. The photon counts of irradiated corn powder were measured by PPSL immediately after irradiation and exhibited an increase with increasing irradiation dose. The photon counts of irradiated com powder almost disappeared with lapse of time in room conditions, but detection of irradiation was still possible after one month at darkroom conditions. Consequently, these results suggest that the detection of irradiated com powder is possible by both viscometric and PPSL methods.

  • PDF