• Title/Summary/Keyword: 광학 정렬

Search Result 254, Processing Time 0.041 seconds

Design of 3-Axis Focus Mechanism Using Piezoelectric Actuators for a Small Satellite Camera (소형 위성 카메라의 압전작동기 타입 3-축 포커스 메커니즘 설계)

  • Hong, Dae Gi;Hwang, Jai Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.3
    • /
    • pp.9-17
    • /
    • 2018
  • For Earth observation, a small satellite camera has relatively weak structural stability compared to medium-sized satellite, resulting in misalignment of optical components due to severe launching and space environments. These alignment errors can deteriorate the optical performance of satellite cameras. In this study, we proposed a 3-axis focus mechanism to compensate misalignment in a small satellite camera. This mechanism consists of three piezo-electric actuators to perform x-axis and y-axis tilt with de-space compensation. Design requirements for the focus mechanism were derived from the design of the Schmidt-Cassegrain target optical system. To compensate the misalignment of the secondary mirror (M2), the focus mechanism was installed just behind the M2 to control the 3-axis movement of M2. In this case, flexure design with Box-Behnken test plan was used to minimize optical degradation due to wave front error. The wave front error was analyzed using ANSYS. The fabricated focus mechanism demonstrated excellent servo performance in experiments with PID servo control.

Comparison of Misalignment and Retardation Errors of Dual Rotating Quarter-Wave Plates in Muller-Matrix Ellipsometry (타원편광 분석기에서 정렬오차와 사분파장판의 지연오차로 인한 뮬러 매트릭스 오차 분석)

  • Cheong, Hai Du;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.262-272
    • /
    • 2014
  • Using an ellipsometer with dual rotating quarter-wave plates, we have analyzed the relationship between Fourier coefficients and Mueller matrices in the cases of an error-free optical system and of five systematic errors (alignment errors and retardation errors in the quarter-wave plates, and alignment error in the analyzer). In the case with five systematic errors, simulation results show that retardation errors cause more error in the diagonal elements of the Mueller matrix than do alignment errors. We have found that errors in the Mueller matrix caused by initial misalignment of the dual quarter-wave plates were the same. We have chosen the rotation rates of two quarter-wave plates such that the rotational frequencies ${\omega}_1$ and ${\omega}_2$ differ by a factor of 5, i.e. ${\omega}_2=5{\omega}_1$. The simulation results show 0.18% relative error in the diagonal elements ($m_{22}$ and $m_{33}$) and 200% relative error in the off-diagonal elements ($m_{23}$ and $m_{32}$), when we compare errors caused by misalignment of the analyzer to those caused by initial misalignment of the quarter-wave plates. We can use these results in measuring accurate Mueller matrices of optical materials.

A Study for the Limitation of Measurement Accuracy and Reliability of Autostigmatic Null lens System by Adjustment and Fixing Process (조정방식과 경통고정방식에 대한 자동무수차점 널 렌즈 광학계의 측정 정밀도 한계 및 신뢰도)

  • Lee, Young-Hun;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.440-445
    • /
    • 2005
  • The limitation of measurement accuracy and reliability of autostigmatic null lens system are studied for the cases of using inter-distance of null lenses as the adjustment factor of alignment and fixing the distance by mounting. If we investigate the first case, the wavefront aberration of null lens system is compensated by the adjustment process even though the shape of aspherical surface is not properly fabricated. As the result, it brings about the problem of measurement reliability. However, for the fixing process by mounting null lenses, it doesn't cause the reliability problem because the wavefront aberration of null lens system is not compensated. Further, the fixing process shows nearly same result in measurement accuracy to the adjustment process, that is, $0.0316{\lambda}$ vs. $0.0326{\lambda}$. So, we can conclude the setup for autostigmatic null lens system must be constituted by means of the fixing process. Meanwhile, we introduce and define the alignment aperture on aspheircal mirror, which can be approximated as spherical zone for alignment of null lens system, and besides, we calculate the required fabrication accuracy of the zone for the necessary measurement accuracy.

Optical coupling coefficients and packaging of optical transmitter module for optical subscriber (광가입자용 수동광정렬형 광송신 모듈에 대한 광결합 효율 및 패키징)

  • 김상곤;송민규
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.179-186
    • /
    • 2000
  • Optical coupling coefficients and misalignment tolerance of 155 Mbps optical transmitter module of passive alignment technology, to be usable in ATM system, B-NT (Broadband Network Termination) system, and 10 G transmission system for information super-highway networks, were calculated, compaired with it's engineer samples, and discussed. These engineer samples of -4.5 dBm maximum output power were packaged in the method of butt coupling of flat-fiber and tested reliability evaluation. Hence the cheap packaging method of optical transmitter module was researched. rched.

  • PDF

Development of an Optical Alignment Control Module with High Speed and Accuracy for Optics-Based Products (광학제품을 위한 고속.고정밀 광정렬 제어 모듈 개발)

  • Kim Seung-Chul;Kim Gyung-Bum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.103-110
    • /
    • 2006
  • Automatic optical alignment modules are a key technology in optical communication system. However, the optic component assembly depends highly on manual or semi-automated alignment process. In this paper, a novel alignment mechanism with minimum degree-of-freedom has been designed and theoretical models are derived from geometric optical characteristics on collimators, optical filters and optical ray alignment. The automatic alignment control algorithm has been newly developed based on the mechanism and models, and then we make fast, precise and reliable alignment through the algorithm. The reliability of developed modules has been verified with various simulations and performance evaluations.