• Title/Summary/Keyword: 광학성능

Search Result 1,082, Processing Time 0.032 seconds

Effect of microwave radiation on physical special quality of normal, high amylose and waxy corn starches (마이크로웨이브를 조사한 옥수수전분의 물리적 특성변화)

  • Lee Su Jin;Choe Yeong Hui
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.15 no.1
    • /
    • pp.113-125
    • /
    • 2004
  • Effect of microwave radiation on physico-chemical properties of cor'n starches was studied. Waxy com, com and high amylose com starches of varying moisture content(20~35%) were subjected to microwave processing(2450MHz) at $120^{\circ}$ and the experimental starch samples were examined by a X-ray diffractometry, rapid viscosity analyzer(RVA) and. with the samples in temperature was observed and the peaks of high amylose com starches at $2^{\circ}$=5.0, 15.0 and $23.0^{\circ}$, were disappeared indicating the melting of crystallines while those of com and waxy com had not changed. A change in gelatinization pattern was observed in the case of corn starches from type A with nearly no peak-viscosity and breakdown to type C. Except a decreased viscosity, no change was observed in those of waxy com starches.

  • PDF

A Study on Evaluating the Possibility of Monitoring Ships of CAS500-1 Images Based on YOLO Algorithm: A Case Study of a Busan New Port and an Oakland Port in California (YOLO 알고리즘 기반 국토위성영상의 선박 모니터링 가능성 평가 연구: 부산 신항과 캘리포니아 오클랜드항을 대상으로)

  • Park, Sangchul;Park, Yeongbin;Jang, Soyeong;Kim, Tae-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1463-1478
    • /
    • 2022
  • Maritime transport accounts for 99.7% of the exports and imports of the Republic of Korea; therefore, developing a vessel monitoring system for efficient operation is of significant interest. Several studies have focused on tracking and monitoring vessel movements based on automatic identification system (AIS) data; however, ships without AIS have limited monitoring and tracking ability. High-resolution optical satellite images can provide the missing layer of information in AIS-based monitoring systems because they can identify non-AIS vessels and small ships over a wide range. Therefore, it is necessary to investigate vessel monitoring and small vessel classification systems using high-resolution optical satellite images. This study examined the possibility of developing ship monitoring systems using Compact Advanced Satellite 500-1 (CAS500-1) satellite images by first training a deep learning model using satellite image data and then performing detection in other images. To determine the effectiveness of the proposed method, the learning data was acquired from ships in the Yellow Sea and its major ports, and the detection model was established using the You Only Look Once (YOLO) algorithm. The ship detection performance was evaluated for a domestic and an international port. The results obtained using the detection model in ships in the anchorage and berth areas were compared with the ship classification information obtained using AIS, and an accuracy of 85.5% and 70% was achieved using domestic and international classification models, respectively. The results indicate that high-resolution satellite images can be used in mooring ships for vessel monitoring. The developed approach can potentially be used in vessel tracking and monitoring systems at major ports around the world if the accuracy of the detection model is improved through continuous learning data construction.

Gap-Filling of Sentinel-2 NDVI Using Sentinel-1 Radar Vegetation Indices and AutoML (Sentinel-1 레이더 식생지수와 AutoML을 이용한 Sentinel-2 NDVI 결측화소 복원)

  • Youjeong Youn;Jonggu Kang;Seoyeon Kim;Yemin Jeong;Soyeon Choi;Yungyo Im;Youngmin Seo;Myoungsoo Won;Junghwa Chun;Kyungmin Kim;Keunchang Jang;Joongbin Lim;Yangwon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1341-1352
    • /
    • 2023
  • The normalized difference vegetation index (NDVI) derived from satellite images is a crucial tool to monitor forests and agriculture for broad areas because the periodic acquisition of the data is ensured. However, optical sensor-based vegetation indices(VI) are not accessible in some areas covered by clouds. This paper presented a synthetic aperture radar (SAR) based approach to retrieval of the optical sensor-based NDVI using machine learning. SAR system can observe the land surface day and night in all weather conditions. Radar vegetation indices (RVI) from the Sentinel-1 vertical-vertical (VV) and vertical-horizontal (VH) polarizations, surface elevation, and air temperature are used as the input features for an automated machine learning (AutoML) model to conduct the gap-filling of the Sentinel-2 NDVI. The mean bias error (MAE) was 7.214E-05, and the correlation coefficient (CC) was 0.878, demonstrating the feasibility of the proposed method. This approach can be applied to gap-free nationwide NDVI construction using Sentinel-1 and Sentinel-2 images for environmental monitoring and resource management.

Experimental Study on Improving Compressive Strength of MWCNT Reinforced Cementitious Composites (MWCNT 보강 시멘트 복합체의 압축강도 향상에 대한 실험적 연구)

  • Kang, Su-Tae;Park, Soon-Hong
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.63-70
    • /
    • 2014
  • This experimental study was intended to improve the compressive strength of multi-walled CNT reinforced cementitious composites with efficiency. The variables considered are the degree of sonication, the amount of surfactant, the replacement ratio of silica fume, etc. Optical microscope informed that fiber dispersion of CNT was improved with the increase of sonication time, and the compressive strength was proved to be enhanced as the degree of sonication increased. When superplasticizer as a surfactant had SP/CNT ratio of 4~6, the best improvement in strength was obtained. Silica fume was shown to produce the highest compressive strength at 10% replacement. Microstructure of CNT composites was also analyzed; XRD and SEM results indicated that CNT addition hardly changed hydration products and microstructure, and MIP analysis found the reduction of total porosity as well as the increase of nano-pores with the size of tens of nm instead of the decrease of pore distribution in the region of around 10 ${\mu}m$ and 100 nm. The results of microstructure analysis explains that the strength improvement is closely related to physical contribution rather than chemical influence by adding CNT.

Wear Behaviors of WC-CoCr and WC-CrC-Ni Coatings Sprayed by HVOF (고속화염 용사법으로 제조된 WC-CoCr 코팅과 WC-CrC-Ni 코팅의 내마모 거동)

  • Lee, Seoung Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.204-211
    • /
    • 2020
  • The high-velocity oxy-fuel (HVOF) thermal spraying coating technique has been considered a promising replacement for traditional electrolytic hard chrome plating (EHC), which caused environmental pollution and lung cancer due to toxic Cr6+. In this paper, two types of cermet coatings were prepared by HVOF spraying: WC-CoCr and WC-CrC-Ni coatings. The produced coatings were analyzed extensively in terms of the micro-hardness, porosity, crystalline phase and microstructure using a hardness tester, optical microscopy, X-ray diffraction, and scanning electron microscopy (including energy dispersed spectroscopy (EDS)), respectively. The wear and friction behaviors of the coatings were evaluated comparatively by reciprocating sliding wear tests at 25 ℃, 250 ℃, and 450 ℃. The results revealed correlations among the microstructures, metallic binder matrixes, porosities, and wear performance of the coatings. For example, WC-CoCr coatings showed better sliding wear resistance than WC-CrC-Ni coatings, regardless of the test temperature due to the more homogeneous microstructure, Co-rich, Cr-rich metallic binder matrix, and lower porosity.

Effect of Pressure on HCl Absorption Behaviors of a K-based Absorbent in the Fixed Bed Reactor (고정층 반응기에서 K-계열 흡수제의 압력에 따른 HCl 흡수 거동 연구)

  • Kim, Jae-Young;Park, Young Cheol;Jo, Sung-Ho;Ryu, Ho-Jung;Baek, Jeom-In;Park, Yeong Seong;Moon, Jong-Ho
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.165-172
    • /
    • 2013
  • In this study, the hydrogen chloride removal using K-based dry sorbents ($K_2CO_3/Al_2O_3$, KEPRI, Korea) was studied with varying the pressure in a fixed bed reactor (15 cm tall bed with 0.5 cm I.d.). Working temperature was $400^{\circ}C$ and feed gas concentration was 750 ppm (HCl vol%, $N_2$ balance). The chloride sorption capacity of sorbent increases with increasing pressure (1, 5, 10, 15 and 20 bar). Also, after forming KCl crystal by reaction with $K_2CO_3$ and HCl, owing to the strong bonding energy, sorbent regeneration was practically impossible. Its optical, physical and chemical characterizations were evaluated by SEM, EDAX, BET, TGA and XRD. At $400^{\circ}C$ and 20 bar condition, working condition for the dehalogenation process after gasification, K-based dry sorbent showed high HCl sorption capacity and HCl/$N_2$ separation performances comparing with Ca-based and Mg-based dry sorbents.

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

Improvement of the performance of SPPCM using mixed polarized beam and cylindrical lens (혼합 편광빔과 원주면렌즈를 사용한 SPPCM의 성능 개선)

  • Yi, Eun-Hyeong;Kim, Seong-Wan;Kim, Cheol-Su;Kim, Jong-Yun;Lee, Seung-Hee;Lee, Soo-Joong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.56-63
    • /
    • 1999
  • Conventional method to improve the response time of the Cat-SPPCM was to increase fanning beam using cylindrical lens. But, in this case the temporal instability of this SPPCM is increased, and fanning beam plays a role as noise, so that it decreases the reflectivity. Thus, fanning beam must be controlled to improve the properties of SPPCM. In this paper, we propose the method to increase the reflectivity of SPPCM and decrease the response time by focusing line-shaped input beam into photorefractive crystal using cylindrical lens and decrease the temporal instability of output beam by using mixed-polarized beam instead of simple extraordinary polarized beam. Optical experiments show that the reflectivity of proposed SPPCM is increased twice and the response time is reduced by 15 times. Also, we observed that the temporal instability of SPPCM is reduced when the polarization angle of the mixed-polarized beam is between $10^{\circ}$ and $30^{\circ}$ . We used a $45^{\circ}-cut\;BaTiO_3$ crystal which has high electro-optical coefficients in optical experiments.

  • PDF

EVALUATION OF ECTOPIC BONE FORMATION EFFECT BY DECALCIFIED DEGREE OF ALLOGRAFTS (동종이식골의 탈회정도가 이소성 골형성유도에 미치는 영향)

  • Yun, Hong-Sik;Chin, Byung-Rho;Shin, Hong-In
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.139-147
    • /
    • 1998
  • This study has been performed to evaluate the relationship between the remained mineral components in a decalcified bone matrix and an ectopic bone formation efficiency. The freezed rat diaphyseal cortical bones measuring 0.5cm in length were demineralized in heated 0.6N HCl at $60^{\circ}C$ for 5, 10, 15, 20, 25, 30, 35, 40 minutes, respectively, using a controlled heat ultrasonic cleaner. Each 1cc of decalcifying solution taken during decalcification procedure was used to calculate calcium content using calcium dignostics kit under 600nm of spectrophotomer. After decalcification, each specimen was also weighed. Then each prepared specimen was implanted into the dorsal pouch of 24 Sprague-Dawley rats divided into 8 groups by time course. The implants were harvested at 1, 2, and 3 weeks and prepared for routine H-E stain specimens to evaluate osteogenic activity. The results are as follows: 1. There was statistical significant difference in change of calcium concentration up to demineralization of 30 minutes and each allogenic bones decalcifed up to 20 minutes revealed 99.65% of decalcification in average. 2. There was statistical significant difference in change of weight in demineralized allogenic bone up to 20 minutes treatment but, no significant change was noted after that time. 3. The histologic analysis revealed active ectopic bone formation in the implanted allografts demineralized for 20, 25, 30 minutes, respectively. However, the other groups of allografts showed relatively poor osteoinductive activity. These findings suggest that complete decalcification with a minimized degeneration of collagen matrix is necessary to induce maximal osteogenesis by decalcified bone allograft.

  • PDF

Adhesion properties of Microorganisms onto surfaces of phosphorylcholine(PC)-modified copolymer for sensor applications (센서 응용을 위해 포스포릴 콜린으로 개질된 고분자 막 표면의 미생물 점착 특성)

  • Kim, Sun-Yong;Sohn, Ok-Jae;Chae, Kyu-Ho;Rhee, Jong-II
    • KSBB Journal
    • /
    • v.23 no.3
    • /
    • pp.226-230
    • /
    • 2008
  • In this study we have studied adhesive properties of various microorganisms onto surfaces of phosphorylcholine-based copolymer for the application of optical biosensors. Three microorganisms, E.coli JM109, B.cereus 318, P.pastoris X-33 were cultivated in confocal cultivation dishes with glass surface, respectively. The glass surface was coated with copolymer containing 0% 5% and 10% MPC (2-methacryloxyethyl phosphorylcholine). After cultivation, culture medium was discarded and adhered microorganisms were dyed by gram staining method. Adhered microorganisms were analyzed using an optical microscope and scanning electronic microscope (SEM). A great number of microorganisms, $2-3{\times}10^3/mm^2$ were adhered on the surfaces of glass and copolymer membrane without MPC. But the antifouling effects of copolymer containing 5% and 10% phosphorylcholine were large, that microorganisms of less than $50-100/mm^2$ were attached on the copolymer membranes. Thus, the copolymer containing phosphorylcholine is very useful as an antifouling coating material for optical biosensor.