• Title/Summary/Keyword: 광학계 변조전달함수

Search Result 15, Processing Time 0.017 seconds

MTF Measuring Equipment of Optical System for LCD Substrate Inspection (LCD 기판 검사 광학계의 MTF 측정장치 제작)

  • Hong, Sung-Mok;Kim, Hee-Nam;Jo, Jae-Heung;Lee, Yun-Woo;Lee, Hoi-Youn;Yang, Ho-Soon;Lee, In-Won;Jung, Jin-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • We developed the equipment to measure the MTF(modulation transfer function) of an optical system for automatically inspecting the surface condition of an LCD substrate. We have made an object generator with USAF(United States Air Force) targets of three bar patterns and an integrating sphere, and an image analyzer with a 2 dimensional CCD(charge coupled device) and a relay lens. The MTF of the lens under test was obtained by correcting the measured CTF(contrast transfer function) which is the ratio of the contrast in the image of the USAF target to the contrast in the object. We have measured an optical system of F/13.65 (2.6x), the MTF are 30.6 % tangential plane and 26.1 % sagittal plane at 62.5 1p/mm.

Study of MTF Measure That Adopts a Fitting Curve for the Variable Angle of a Slant Target in Presampled MTF (Presampled MTF 기법에서 Slant Target의 다양한 각도에 대한 함수 Fitting이 적용된 MTF 측정기법에 관한 연구)

  • Choi, Siyoun;Kim, Junghwan;Kong, Hyunbae;Kim, Donghwan;Baek, Kyounghoon;Park, Ingu;Jeon, Hyowon;Lee, Kinam
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.310-316
    • /
    • 2022
  • In this paper, the difference in modulation transfer function (MTF) results according to the change in the angle of a slant target when measuring a presampled MTF was confirmed, and the difference was reduced by fitting the edge spread function graph obtained to reduce the error by the target's rotation. Due to the feature of the presampled MTF method, the spatial frequency changed due to the sensor's projected intensity being changed by the target's rotation, and it was confirmed that the difference in the MTF value occurred depending on the rotation angle of the target. In this paper, the MTF was calculated after fitting only one column of the acquired image. It was confirmed that the rotation error is smaller compared to the case of the presampled MTF method and this fitting method can be applied to a scene that contains various target angles, such as auto-focusing using the MTF.

Optical Design of a Subminiature Catadioptric Omnidirectional Optical System with an LED Illumination System for a Capsule Endoscope (LED 조명계를 결합한 캡슐내시경용 초소형 반사굴절식 전방위 광학계의 설계)

  • Moon, Tae Sung;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.68-78
    • /
    • 2021
  • A subminiature catadioptric omnidirectional optical system (SCOOS) with 2 mirrors, 6 plastic aspherical lenses, and an illumination system of 6 light emitting diodes, to observe the 360° panoramic image of the inner intestine, is optically designed and evaluated for a capsule endoscope. The total length, overall length, half field of view (HFOV), and F-number of the SCOOS are 14.3 mm, 8.93 mm, 51°~120°, and 3.5, respectively. The optical system has a complementary metal-oxide-semiconductor sensor with 0.1 megapixels, and an illumination system of 6 light-emitting diodes (LEDs) with 0.25 lm to illuminate on the 360° side view of the intestine along the optical axis. As a result, the spatial frequency at the modulation transfer function (MTF) of 0.3, the depth of focus, and the cumulative probability of tolerance at the Nyquist frequency of 44 lp/mm and MTF of 0.3 of the optimized optical system are obtained as 130 lp/mm, -0.097 mm to +0.076 mm, and 90.5%, respectively. Additionally, the simulated illuminance of the LED illumination system at the inner surface of the intestine within HFOV, at a distance of 15.0 mm from the optical axis, is from a minimum of 315 lx to a maximum of 725 lx, which is a sufficient illumination and visibility.

A Study on the Method of Evaluating Optical-system Performance and an Athermal Structure through Thermal Analysis of the Korsch Telescope (Korsch 망원경의 열분석을 통한 광학계 성능 평가 방법 및 비열화 구조 연구)

  • Kim, Kyu-Ho;Park, Seong-Woo;Park, Seung-Han;Lee, Kyoung-Mook;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.266-275
    • /
    • 2021
  • In this paper, a method for evaluating optical-system performance and an athermal structure through thermal analysis of the Korsch telescope was studied. In the case of an optical system having a complex asymmetrical structure, there is a limit to implementing the satellite structure by applying the coefficient of thermal expansion (CTE) in the optical-design software, so it is difficult to evaluate the performance of the optical system against temperature changes. To solve this problem, using mechanical design software all length changes were implemented in all structures that affect the optical system according to temperature, and the value of the change in distance between optical components due to temperature change was organized. Also, the values of changes in shape and thickness of the optical components against temperature changes are organized in the optical-design software. All changes derived from both software packages were applied in the optical software to evaluate the performance of the optical system. As a result, it was found that the MTF for a spatial resolution of 71.4 cycles/mm was maintained at more than 25% in the range from 9 ℃ to 33 ℃. In addition, the performance of the optical system applying the improved structure was evaluated, by finding the structure that had the most influence on the optical system's performance change, and deriving an athermal structure to reduce the effect. As a result, it was found that the MTF for a resolution of 71.4 cycles/mm was maintained at over 67% in the range from 9 ℃ to 33 ℃.

Optical Design of a Modified Catadioptric Omnidirectional Optical System for a Capsule Endoscope to Image Simultaneously Front and Side Views on a RGB/NIR CMOS Sensor (RGB/NIR CMOS 센서에서 정면 영상과 측면 영상을 동시에 결상하는 캡슐 내시경용 개선된 반사굴절식 전방위 광학계의 광학 설계)

  • Hong, Young-Gee;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.286-295
    • /
    • 2021
  • A modified catadioptric omnidirectional optical system (MCOOS) using an RGB/NIR CMOS sensor is optically designed for a capsule endoscope with the front field of view (FOV) in visible light (RGB) and side FOV in visible and near-infrared (NIR) light. The front image is captured by the front imaging lens system of the MCOOS, which consists of an additional three lenses arranged behind the secondary mirror of the catadioptric omnidirectional optical system (COOS) and the imaging lens system of the COOS. The side image is properly formed by the COOS. The Nyquist frequencies of the sensor in the RGB and NIR spectra are 90 lp/mm and 180 lp/mm, respectively. The overall length of 12 mm, F-number of 3.5, and two half-angles of front and side half FOV of 70° and 50°-120° of the MCOOS are determined by the design specifications. As a result, a spatial frequency of 154 lp/mm at a modulation transfer function (MTF) of 0.3, a depth of focus (DOF) of -0.051-+0.052 mm, and a cumulative probability of tolerance (CPT) of 99% are obtained from the COOS. Also, the spatial frequency at MTF of 170 lp/mm, DOF of -0.035-0.051 mm, and CPT of 99.9% are attained from the front-imaging lens system of the optimized MCOOS.

Non-Paraxial Diffraction Effect of High NA Objectives (높은 개구수를 가지는 대물렌즈의 비근축 회절효과)

  • Lee, Jong Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.8-13
    • /
    • 2014
  • By using finite ray-tracing and curve fitting, a numerical method to determine the non-paraxial pupil function of a high-NA objective is presented. MTF degradations caused by the non-paraxial diffraction effect are analyzed for on-axial imaging of a far-infrared objective and aberration-free ellipsoidal mirror system. The ellipsoidal mirror system has the same paraxial specifications as the far-infrared objective.

A Serial-Parallel Scanner Optics for Thermal Imaging System (열상장비용 직병렬주사광학계)

  • 김창우;김현숙;홍석민;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.212-216
    • /
    • 1994
  • We have designed and constructed a scanner optics for thermal imaging system operating in 8 - 12 /lfll band. The scanner consists of rotating polygon and oscillating mirror for serial-parallel scan using 5 elements SPRITE HgCdTe. A spherical mirror is used for scan relay mirror to minimize size of the scan mirrors and pupil aberration. The scanner has $40^{\circ}\times26.67^{\circ}$ wide scan field of view and the calculated diffraction MTF shows diffraction limited performance. As a result we have obtained high resolution thermal image. image.

  • PDF

Design and Performance of a Catadioptric Omnidirectional Zoom Optical System Using a Hybrid Lens for Visible Light (가시광에서 하이브리드 렌즈를 사용한 반사굴절식 전방위 줌 광학계의 설계 및 성능평가)

  • Park, Hyun Sik;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.2
    • /
    • pp.96-104
    • /
    • 2020
  • A catadioptric omnidirectional zoom optical system using a hybrid lens (COZOSH) that performs simultaneously two functions of a lens and a mirror was designed at the visible wavelength range for daytime unmanned surveillance, and its performance was analyzed. The hybrid lens has lots of advantages in terms of fabrication and assembly of a COZOSH, because of the obviation of a lens boring process and reduction of the number of optical components. Additionally, we designed the COZOSH to expand the compressed inner-image region of a donut image at low spatial frequencies. As a result, the optimized design performance of the optical system that satisfies all initial design specifications was obtained from calculation of the modulation transfer function, spot diagram, and tolerance analysis. We confirmed that the COZOSH is a passively athermalized optical system under conditions of temperature variation from -30℃ to 50℃, by using athermalization analysis during zooming.

Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass (칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작)

  • Oh, Seung Eun;Lee, Sun Kyu;Choi, Joong Kyu;Song, Kook Hyun;Baek, Jong Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • In this paper, for low cost infrared optical equipment, we design and fabricate an infrared optical system for an uncooled detector using PGM(Precision Glass Molding) lenses. The designed infrared optical system has a good athermalization, and the material of all of its lenses is a chalcogenide glass suitable for the PGM method. In addition, we also fabricate the same infrared optical system using SPDT(Single Point Diamond Turning) lenses in order to measure the optical performance of PGM lenses. We measure the MTF(Modulation Transfer Function) of the two infrared optical systems which use the PGM lenses and the SPDT lenses. And then we compare and analyze the images of them both. As a result, we find that they have only a very small difference in optical performance. If the use of PGM lenses increases, we expect to reduce the cost of infrared optical equipment.

MTF and wavefront error testing of large aperture optical system using unequal path interferometer (경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사)

  • Song, Jong-Sup;Jo, Jae-Heung;Lee, Yun-Woo;Song, Jae-Bong;Yang, Ho-Soon;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2005
  • A method for measuring the wavefront error and the modulation transfer function(MTF) of large aperture optics using an unequal path interferometer is presented. A bidirectional shearing interferometer is used for collimation testing of the measurement system. A large aperture Fizeau interferometer with long optical path difference measures the wavefront error of the optics under test by using a $\Phi$ 400 mm off-axis parabolic mirror. The MTF is also measured at the wavelength of the interferometer by changing the laser light into partially incoherent light. Test results of a $\Phi$ 300 mm Cassegrain type satellite telescope made in Korea are presented.