Design of a Free-form Mueller Matrix Ellipsometer with Imperfect Compensators (불완전한 보정기를 적용한 자유형 뮬러행렬타원계의 설계)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.2
    • /
    • pp.59-66
    • /
    • 2022
  • A free-form Mueller matrix ellipsometer (MME) based on independent control of the azimuthal angle of each polarizing element is introduced. The azimuthal angles of the polarizer and the matching compensator which generate the optimum Stokes vectors of an incident beam are investigated for the polarization state generator, where the spectral responses of the retardation angle and transmittance ratio of a nonideal compensator are taken into account. Similarly, the azimuthal angles of the analyzer and the corresponding compensator are investigated for the polarization-state detector, to unambiguously determine the Stokes vector of the outcoming beam from the sample, and explicit expressions for the Stokes elements are derived. Since the suggested technique enables one to utilize a nonideal quarter-wave plate as the compensator for an MME, it will contribute to the construction and application of a Mueller matrix spectroscopic ellipsometer (MMSE) operating over a wide spectral range from deep ultra-violet to near infrared.

Prediction of the Glucose Concentration Based on Its Optical Absorbance at Multiple Discrete Wavelengths (복수 개의 광파장에 대한 상대적 흡광 특성을 이용한 글루코스 농도 측정)

  • Kim, Ki-Do;Son, Geun-Sik;Lim, Seong-Soo;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.416-421
    • /
    • 2008
  • A scheme for predicting the concentration of a glucose solution based on its relative optical absorbance at multiple probe wavelengths was proposed and verified. The relative absorbance at each of the probe wavelength was obtained with respect to the absorbance at a reference wavelength. The single reference wavelength (1310 nm) and a group of four different probe wavelengths (1064, 1550, 1685, 1798 nm) were selected to exhibit the glucose absorbance with opposite signs, thereby enhancing the accuracy of the prediction. The final glucose concentration was estimated by taking the average of the predicted values provided by the four probe wavelengths. The absorbance of the glucose solution for the path length of 5 mm was $-1.42{\times}10^{-6}\;AU$/(mg/dL) at the reference wavelength of 1310 nm and peaked at $+8.12{\times}10^{-6}\;AU$/(mg/dL) at 1685 nm. The concentration of the glucose solution was decently predicted by means of the proposed scheme with the standard error of prediction of ${\sim}28\;mg/dL$. In addition, the influence of the ambient temperature and the fat thickness upon the prediction of the glucose concentration was examined. The absorption change with the temperature was $-9.1{\times}10^{-5}\;AU/^{\circ}C$ in the temperature range of $26{\sim}40^{\circ}C$ at the reference wavelength, and $-2.08{\times}10^{-2}\;AU/^{\circ}C$ at 1550 nm. And the absorption change with respect to the fat thickness was +1.093 AU/mm at the probe wavelength of 1685 nm.

Color Filter Based on a Sub-wavelength Patterned Metal Grating (광파장 이하 주기를 갖는 금속 격자형 컬러필터)

  • Lee, Hong-Shik;Yoon, Yeo-Taek;Lee, Sang-Shin;Kim, Sang-Hoon;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.383-388
    • /
    • 2007
  • A color filter was demonstrated incorporating a patterned metal grating in a quartz substrate. The filter is created in a metal layer perforated with a symmetric two-dimensional array of circular holes, with the pitch smaller than the wavelength of the visible light. A finite-difference time-domain simulation was performed to analyze the device by investigating the effect of structural parameters like the grating height, the period, the hole size, and the refractive index of the hole-filling material on its performance. The device performance was especially optimized by controlling the refractive index of the material comprising the holes of the grating. And two different devices were fabricated by means of the e-beam direct writing with the following design parameters: the grating height of 50 nm, the two pitches of 340 nm for the red color and 260 nm for the green color. For the prepared device with the period of 340 nm, the center wavelength was 680 nm and the peak transmission 57%. And for the other device with the pitch of 260 nm, the center wavelength was 550 nm and the peak transmission was 50%. The filling of the hole with a material whose refractive index is matched to that of the substrate has led to an increase of ${\sim}15%$ in the transmission efficiency.

Refractometric Glucose Biosensor Incorporating a Vertically Coupled Microring Resonator in Polymeric Waveguides (수직형 폴리머 마이크로링 공진기 기반의 글루코스 바이오 센서)

  • Kim, Gun-Duk;Son, Keun-Sik;Lee, Hak-Soon;Kim, Ki-Do;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.127-131
    • /
    • 2008
  • A refractometric glucose biosensor incorporating a vertically coupled microring resonator in polymers was proposed and realized. The ring was covered with a target analyte of glucose solution with a certain concentration, so that its effective refractive index could be altered and, as a result, the resonance wavelength of the sensor was shifted. Therefore the concentration of the glucose solution can be estimated by observing the shift in the resonance wavelength. Two schemes were exploited for enhancing the sensitivity of the sensor. First, the effective refractive index of the polymeric waveguide used for the resonator sensor was adjusted to approach that of the target analyte as best as possible. Second, the ring waveguide, which serves as a crucial sensing part, was appropriately over-etched to enlarge its contact area with the analyte. The proposed resonator sensor was designed with the beam propagation method. The refractive indices of the core and cladding polymer involved were 1.430 and 1.375 respectively, leading to the waveguide's effective refractive index of ${\sim}1.390$, which is faiirly close to that of the glucose solution of ${\sim}1.333$. The prepared ring resonator with the $400-{\mu}m$ radius exhibited the free spectral range of 0.66 nm, the bandwidth of 0.15 nm, and the quality factor of 10,000. For the sensor operating at 1,550 nm wavelength, the achieved sensitivity was as great as 0.28 pm/(mg/dL), which is equivalent to 200 nm/RIU.

Effect of LED Light Wavelength on Lettuce Growth, Vitamin C and Anthocyanin Contents (LED광 파장이 상추생육과 비타민 C 및 안토시아닌 함량에 미치는 영향)

  • Choi, Man Kwon;Baek, Gyeong Yun;Kwon, Soon Joo;Yoon, Yong Cheol;Kim, Hyeon Tae
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • In this study, we analyzed the growth characteristics of red lettuce under Light-emitting diode (LED) light environment as well as the change of vitamin C and anthocyanins of lettuce. We made five monochromatic light treatments (red 647 nm, 622 nm, blue 463 nm, 450 nm, White), six mixed red (R) and blue (B) light treatments (R : B = 9 : 1, 8 : 2, 7 : 3, 6 : 4, 5 : 5) and red + white, and three light treatments made according to photoperiod of LED with lighting sources ratio of red : blue (R : B = 8 : 2(18/06 h, 15/09 h, 12/12 h)). It was composed of totally 14 control beds. As a result, the red lettuce the most developed leaf height, leaf numbers and fresh weight under red single light, root length and leaf developed when grown under blue single light. Therefore, red light were related to above part of the lettuce, blue light were related to the growth of the underground part of lettuce. Case of the mixed light, leaf height, leaf numbers, fresh/dry weight of above and underground part were highest red + white light and root length and chlorophyll content were highest under red 7 : 3 blue light. Result of growing investigation by photoperiod, the red lettuce were considered to be most effective in 15/09 h (on/off). The content of anthocyanins; the single light source, mixed light and light irradiation period were highest under blue light (463 nm), red 7 : 3 blue and 18/06 h (on/off) light irradiation, respectively. The vitamin C showed the lowest content of $1.26mg{\cdot}L^{-1}$ under the white light, but showed the greatest content of $3.02mg{\cdot}L^{-1}$ for the control group.