• Title/Summary/Keyword: 광파이버

Search Result 78, Processing Time 0.021 seconds

A Study on the Development of Optical-Fiber Water Leakage Sensing System (광파이버 누수센싱 시스템 개발에 관한 연구)

  • Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.

A Stabilization Scheme of a Dynamic FOG Compass using the Fuzzy Control (퍼지제어에 의한 동적방식 광파이버 자이로콤파스의 구동시스템 안정화)

  • 권용수;김상우
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.150-158
    • /
    • 1999
  • A driving system of a dynamic FOG compass with a stabilized platform is described. A stepping motor adopted as a driving motor is required to maintain a stable operation with constant speed and low oscillation for the proper operation of the FOG compass itself. The previous stabilization scheme operated on frequency-modulated supply is modified to include fuzzy control algorithm. The proposed scheme has advantages, particularly in the size, weight and flexibility of the driving system.

  • PDF

Digital Signal Processing for a Fiberoptic Fabry-Perot Interferometry (초소형 광파이버 패브리페로 간섭계의 디지털 신호처리)

  • Kim, K.S.;Lee, H.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1820-1822
    • /
    • 2001
  • 광파이버 패브리페로 간섭계에서 동작영역을 넓히기 위해 공진기의 길이를 1mm보다 짧은 초소형 간섭계를 구성하고자 하였을 경우, 광출력의 위상변화에 대한 감도가 낮아 전달함수로부터 변화된 위상을 복원하는 과정이 까다로워진다. 이러한 신호복원 과정에는 대부분 신호잡음비를 높여주는 신호처리 수단을 포함하게 되므로 간섭계가 겪은 위상변화를 보다 높은 신뢰성으로 검출하고자 할 때 어떠한 신호처리 방법이 적절한가하는 선택의 문제가 발생된다. 이는 각각의 신호처리방법이 장단점을 가지므로 응용목적에 따른 trade-off가 필요하기 때문이다. 본 연구에서는 참조 간섭계와 센서 간섭계 간의 correlation으로부터 위상을 검출하여 시스템의 잡음을 common mode 잡음으로 처리할 수 있었으며, 디지털 신호처리기법을 응용하여 짧은 공진기로 구성된 센서 간섭계의 위상변화분을 보다 안정적으로 검출하게 되었다.

  • PDF

Design and Performance Evaluation of the Optical Fiber Position Sensor for the State Monitoring of a High Speed Spindle (고속 주축 상태 모니터링용 광파이버 변위 센서 설계 제작 및 성능평가)

  • 홍준희;박찬규;신우철;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.393-398
    • /
    • 2004
  • This paper is focused on practical applicability of the optical fiber sensor considering the machine center which is going to use them. Optical fibers may be fluctuated because the machine center operates as column moving type. This causes distortion of the sensor output signal. To reduce this problem, we have improved the sensor structure and its bracket. And we evaluated performances of the sensor.

  • PDF

Basic reseach for the development of optical CT for GIS3 (GIS용 Optical CT개발의 기초연구3)

  • Jeon, Jae-Il;Song, Si-Joon;Lee, Jung-Soo;Park, Won-Zoo;Lee, Kyang-Sik;Kim, Jung-Bae;Song, Won-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1837-1839
    • /
    • 2002
  • 본 논문은 패러데이 효과(Faraday Effect)에 의한 초고압 전력설비에서의 광CT 특성에 대한 기초 연구를 기술하였다. 광원은 LD(Laser Diode : 830[nm])를 사용하고, 수신부는 PIN-Photodiode론 사용하였다. 광의 전송로는 파이버 내에서 편광상태론 유지할 수 있는 싱글모드 광파이버를 사용하였고, 광파이버의 양끝은 편광자와 검광자를 두어 빛의 광학적인 편파면을 이용한 전류측정이 가능함을 확인할 수 있었다. 측정 결과에서는 기존 문헌상의 결과와 동일한 형태의 출력을 얻을 수 있었고 나아가서는 초고압전력설비인 가스절연개폐장치 (GIS: Gas Insulated Switchgear)에 대한 적용도 가능하게 했다.

  • PDF

The Performance Evaluation of Fiber Optic Sensor for Monitoring Magnetic Bearing (자기베어링 모니터링용 광파이버센서의 성능 평가)

  • 박한수;정택구;홍준희;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.411-416
    • /
    • 2002
  • In a high speed spindle system, it is very important to monitor the state of rotating rotor. Particularly in active control spindle system, the position sensor must provide feedback to the control system on the exact position of the rotor. In order to monitor the state of a high speed spindle exactly, high accuracy and wide frequency bandwidth of sensors are important. The focus in this paper is to make a fiber optic sensor for monitoring rotor of magnetic bearing, to design the circuit for detecting optical signal, and to evaluation static and dynamic characteristics of fiber optic sensor.

  • PDF

Fabrication and Performances Tests of the Optical Fiber Position Sensor for Application to Spindle State Monitoring (주축 상태 모니터링 용 광파이버 변위센서 제작 및 성능평가)

  • Shin Woo-cheol;Hong Jun-hee;Park Chan-gyu
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.37-44
    • /
    • 2005
  • This paper presents fabrication techniques of the optical fiber position sensor (or spindle state monitoring. These include selection of components such as optical fibers, a laser-diode, a photo-diode, and op-amp IC of the signal process circuit. We also describe electric runout problem. The fabricated sensor has a linearity of $1.7\%$ FSO in the air gap range $0.1\~0.6mm$, a resolution of $0.37{\mu}m$ and a bandwidth of 6.3kHz. Finally, we have successfully operated a magnetic bearing spindle system using the sensors.

Fundamental Experiment to Verify the Resolution of Hetero-core Fiber Optic Sensor for the Prestress Measurement (프리스트레스 측정을 위한 헤테로코어 광파이버 센서의 분해능 검증 기초실험)

  • Park, Eik-Tae;Choi, Kwang-Su;Kim, Tae-Yang;Lee, Hwan-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.259-266
    • /
    • 2018
  • This is the study for developing the hetero-core optical fiber sensors which are purpose to measure the prestress of PSC bridges during the life cycle period. The goal of this study is to improve the resolution of hetero-core sensors. As a result of the test, it is possible to measure the displacement in $2{\mu}m$ increments. In other words, if the length of the sensor module is 30cm, it is possible to measure the prestress variations in 0.2MPa increments at specified compressive strength of concrete(fck) of 40MPa by Hook's Law. So it can be useful for development of a sensor module measuring internal prestress measurement.

Hetero-core Optical Fiber Exposure Sensor Module and Instrumentation Delay (헤테로코어 광파이버 노출형 센서모듈과 계측 지연현상)

  • Song, Young-Yong;Park, Eik-Tae;Lee, Hwan-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.401-408
    • /
    • 2019
  • The objective of this study is to develop a new type of buried sensor module that can directly assess pre-stressed concrete by measuring strain using a hetero-core optical fiber sensor. In this regard, experiments were conducted to evaluate the performance of the sensor using an exposure sensor module. Based on the experimental results, when the values of the displacement control velocity were 0.12 mm/min and 1.80 mm/min, the corresponding delays in the measurement were 52.1 s and 2.6 s respectively, which indicated that the maximum delay between the two measurements was a factor of 19. Due to the measurement delay phenomena, the sensor module used in the experiments cannot be employed to check the real-time state of the structure. Thus, additional experiments were needed to develop a new sensor module that can measure the real-time state of the structure. To investigate the cause of the measurement delay phenomena, three experiments were conducted. It was confirmed that measurement delay is mainly attributed to frictional resistance. The measurement delay phenomena were not observed in the experiments using the friction-removed device.