Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Correction Method on Mismatched Posterior Edge of Medial and Lateral Tangential Fields for Three Fields Techniques in Breast Cancer (유방암 환자의 삼문 조사 시 내외측 접면 조사야의 Posterior Edge의 어긋남의 교정)

  • Kim Hun-Jung;Loh John JK;Kim Woo-Cheol;Park Sung-Young
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.174-181
    • /
    • 2003
  • Purpose: The target volume for the three field technique in breast cancer include the breast tangential and supraclavicular areas. The techniques rotating the gantry and couch angles, to match these two areas, will geometrically produce mismatching of the posterior edge between the medial and lateral tangential beams. This mismatch was confirmed by film dosimetry and three-dimensional computer planning. The correction methods of this mismatching were studied in this article. Materials and Methods: After the supraclavicular field was simulated using a half beam block and the medial and lateral tangential fields, by the rotation of the couch and gantry, we compared the following two methods to correct the mismatch. The first method was the rotation of coillmator until a line drawn on the posterior edge of tangential beams before the rotation of couch aligned the line drawn on the posterior edge after the rotation. The second method was the rotation of collimator according to the formula developed by the author as follows; Co=$2sin^{-1}${$sin\{theta}\{cdot}sin(C/2)$} (Co: collimator angle, $\theta$: angle between tangential beam and table, C: couch angle) Results: The film dosimetry showed the mismatching of posterior edges of the medial and lateral tangential fields prior to the rotation of collimator, while the posterior edges matched well after the rotation of collimator according to the formula. The three-dimensional computer plan also showed that the posterior edges matched well after the rotation of collimator accordingly. The DVH of the ipsilateral lung with the proper rotation of collimator angle was better than that without the rotation of collimator angle. Conclusion: The mismatching of the posterior edges of the medial and lateral tangential fields can be recognized on the three fileld technique in breast irradiation when the gantry and couch are simultaneously rotated and can be corrected with the proper rotation of the collimator angle. The radiation dose to the ipsilateral lung could be lowered with this technique.

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

Clinical Features Affecting the Efficacy of Systemic Clonazepam for Management of Burning Mouth Syndrome (구강작열감증후군의 치료를 위한 전신적 클로나제팜의 투여 시 환자의 임상적 특징에 따른 효능의 차이에 관한 연구)

  • Min, Bo-Kyong;Jung, Jae-Kwang;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.3
    • /
    • pp.161-167
    • /
    • 2012
  • Burning mouth syndrome(BMS) is defined as chronic, painful burning sensation in the oral mucosa. Treatments for BMS include medication and psychiatric interventions. Capsaicin, alpha-lipoic acid, and topical and systemic clonazepam showed more effective in reducing the symptoms of BMS in the previous studies. The purpose of this study is to evaluate of the therapeutic efficacy of systemic clonazepam in BMS and to elucidate the relationships between such a efficacy and various clinical features, including age, pain intensity, pain duration, previous dental history and condition of oral mucosa. A retrospective clinical records audit was performed of patients diagnosed with BMS between January 2011 and August 2012. Patients were prescribed 0.5 mg clonazepam two times daily. Pain was assessed by patients on an 11-point numeric rating scale (NRS; 0 to 10) before and 1-2 weeks after systemic administration of clonazepam. The efficacy of clonazepam was evaluated in terms of patient's age, initial pain intensity, pain duration, presence or absence of precipitating event, condition of the tongue, presence or absence of denture. A total of 50 patients (46 women, 4 men) were included in this study. The patients were divided into two or three groups according to above clinical features. The amount of mean NRS reduction in patients with severe initial pain was $3.33{\pm}2.74$, whereas that in patients with mild initial pain was $1.64{\pm}1.54$. The amount of mean NRS reduction in oldest patients was $3.53{\pm}1.94$ (${\geq}$70yrs), and those in another younger patients were $2.88{\pm}1.80$(< 60yrs) and $1.54{\pm}2.86$(60yrs ${\leq}$ age < 70yrs), respectively. It was concluded that the older patients and the patients with higher intensity of initial pain tend to show better efficacy of clonazepam. However, There were no statistically significant differences according to pain duration, presence or absence of precipitating events, tongue fissuring, and wearing dentures.

A Clinical Study on the Surgical Treatment of the Rheumatic Cardiac Valve Disease (류마티스성 심장판막질환의 외과적 치료에 대한 임상적 연구)

  • 김종원;정황규;이성광;김병준;신영우
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.346-352
    • /
    • 1998
  • Rheumatic valvulitis produces at least three distinct pathologic changes, the degree varying widely among the patients: fusion of the valve leaflets at the commissures; fusion and shortening of chordae tendinae: and fibrosis of the leaflets with subsequent stiffening, contraction and calcification. The most extensive changes usually are seen in patients with recurrent attacks of rheumatic fever. We studied on outcome of the surgical treatments of rheumatic valvular diseases that have been experienced for 12 years since 1982 at Pusan National University Hospital. The diagnoses were made by rheumatic fever history, echocardiographic findings, gross operative findings and microscopic findings. Total 502 patients were performed surgery for valvular heart diseases and 440 patients of rheumatic origin have bene analysed. There were more female than male patients as 1.3:1, and the mean age was 37.8 years old. 96.3% of them affected to the mitral valve, 19.8% to aortic valve, 16.3% affected to the tricuspid valve. Most of them underwent valve replacement, and valve repair was done in 3.9% of patients. There were 36 hospital deaths(8.2%) mainly from low cardiac output syndrome, and 15 late deaths equally due to embolism and hemorrhage. Follow up was 90.1% completed(2890 patient- year). Linealized rates of late complication events are follows : thromboembolism 1.3% per patient year; anticoagulant related hemorrhage 0.8% per patient year. Overall actuarial survival including hospital mortality was 92.7+/-2.9% in 1 year, 88.0+/-4.5% in 5 year, 82.3+/-7.7% in 10 year. We conclude that the rheumatic disease is still the most frequent and the most important cause of heart valve disease. So more intensive study is needed in spite of the abrupt decreasing rate of rheumatic fever in U.S.A. and other industrial country.

  • PDF

DEVELOPMENT OF HIGH SENSITIVE MODEL OF CARIES ACTIVITY TEST FOR EARLY DIAGNOSIS OF DENTAL CARIES (치아우식증의 조기진단을 위한 고감도 우식활성검사 모형개발)

  • Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.169-179
    • /
    • 2000
  • The purpose of this study is to develop the system which convert the optical difference of teeth texture between intact enamel and incipient caries lesion into shade difference by laser fluorescence and to develop new and simple caries activity test using laser fluorescence. The experimental design of this study consists of three parts. In first part, a new method for the in vitro assessment of changes in initial enamel caries lesion of Bovine teeth using laser fluorescence is tested. In second part, in vivo assessment undertaken. Number of teeth which showed incipient carious lesion on buccal surface examined by laser fluorescence was compared with the caries activity test of $Cariescreen^{(R)}$ test and other oral environmental test of dDfFtT. In third part, new caries activity test measured by laser fluorescence was developed on the basis of above results and evaluated the sensitivity, specificity, and diagnostic power. Optical density measured by laser fluorescence was increased as increasing the depth of incipient carious lesion and showed high correlation$(\gamma=0.7015)$ with lesion depth. Optical density showed direct proportion to lesion depth. Linear equation was obtained between the optical density and the lesion depth by regression analysis. The result of caries activity test with laser fluorescence showed high correlation with those of $Cariescreen^{(R)}$ test and dDfFtT examination. Caries activity test with laser fluorescence showed 48% of sensitivity, 52% of specificity, and 45% of diagnostic power on the basis of dDfFtT examination, and also showed 48% of sensitivity, 51% of specificity, and 36% of diagnostic power on the basis of $Cariescreen^{(R)}$ test. In regard above result, caries activity test with laser fluorescence considered to be reliable for caries activity test compared with other oral environmental test. and it was also considered to be practical because it would be simple, inexpensive, and time saving method.

  • PDF

Effect of Different Types of Bonding Agent and Application Methods on Shear Bond Strength of Orthodontic Bracket (Bonding agent의 종류 및 적용 방법에 따른 교정용 브라켓의 전단결합강도에 관한 연구)

  • Lee, Jaehee;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.419-426
    • /
    • 2017
  • Attachment of the orthodontic bracket conducted during the window opening procedure can result in failure due to various adverse conditions such as blood or saliva contamination, or other wet conditions. For the success of the bracket attachment, reduction of total operation time is crucial. The purpose of this literature is to evaluate the differences between the final resultant shear bond strength of the conventional method of using phosphoric acid and self-etching primer, and that of the operation time-reduced method in which the curing step is omitted subsequent to the primer application. A total of 40 human maxillary incisors were prepared. Group I(control group) and II were etched with 37% phosphoric acid and Group III and IV were conditioned with self-etching primer. Attachment of the group I and III was conducted by manufacturer's instructions. The operation time of Group II and IV was reduced by eliminating the curing step after the primer application. The resultant shear bond strength of each group was measured and an adhesive remnant index (ARI) was recorded. The mean shear bond strength of group I, II, III, and IV were 14.16 MPa, 8.33 MPa, 8.29 MPa, and 6.48 MPa respectively. Significant differences could only be found between the control group and the experimental groups (p < 0.05). The ARI indicated no significant difference among all groups.

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

A STUDY OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO FILLING METHODS USING STRAIN GAUGE (스트레인 게이지를 이용한 적층방법에 따른 복합레진의 중합수축에 관한 연구)

  • Kim, Eung-Hag;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.18-29
    • /
    • 2008
  • The purpose of this study was to compare the polymerization shrinkage of several filling methods using strain gauges. In this study, a light-emitting diode(LED) curing unit(Elipar Freeligh2, 3M EPSE, USA) and plasma arc lamp(PAL) curing unit(Flipo, LOKKI, France) were used for curing, Filtek $Z350^{TM}$(3M EPSE, USA) composite resin was used for the cavity filling. Sixty permanent bicuspid teeth, that were extracted for orthodontic treatment, were studied. The cavities were prepared on the occlusal surface and were filled using the following methods : 1) bulk filling, 2) parallel filling, 3) oblique filling The strain was recorded on the buccal, lingual, mesial and distal surfaces and the strain values were computed into stress values. The shear bond strength of each filling method was tested using a Micro Universal Testing machine. The results can be summarized as follows: 1. In the strain changes, all LED and PAL curing groups showed an increase on the buccal surface and a slow decrease as time elapsed. 2. In the strain changes of the mesial and distal surfaces, the decreases and increases were shown repeatedly and reduced as time elapsed. 3. There were no significant statistical strain changes among filling methods in the LED or PAL curing groups. 4. There were significant statistical strain changes between the LED and PAL curing groups on the buccal surface(p<0.05). 5. From the shear bond strength results, in the LED curing group, filling method 3 showed lower surface stress than filling method 1 and 2(p<0.05). In the PAL curing group, there were no significant statistical strain changes between each filling method. 6. The surface stress of each group was lower than the shear bond strength.

  • PDF