• Title/Summary/Keyword: 광자에너지

Search Result 258, Processing Time 0.026 seconds

Direct Measurement of Chamber Response Function and Its Application to Radiation Dose Distribution Dosimetry (전리함 반응 함수의 직접 측정과 이를 이용한 방사선의 실제선량 분포측정)

  • Lee Sang Hoon;Cho Byung Chul;Kim Jong Hoon;Choi Eun Kyung;Kwon Soo Il;Chang Hyesook;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.65-69
    • /
    • 1997
  • Purpose : To obtain the actual dose distribution from measured data by doconvolution method using the measured ion chamber response function. Materials and Methods : The chamber response functions for 2 ionization chambers (diameter 5mm, 6.4mm) were measured. and dose Profiles were measured for $10{\times}20cm^2$ field size using two different detectors. The deconvolution of chamber response function from the measured data were performed for these Profiles. The same procedures were repeated for 4MV, 6MV and 1 SMV photon energies. Results : Different dose Profiles were obtained for the same field with the chambers which have the different response functions. Nearly the same results could be obtained with deconvolution for the profiles from various detectors. Conclusion : The effect of the chamber response function can be extracted by deconvolution method. Deconvolved dose profile using various ionization chambers gave better dose distributions. Technical improvements are needed for practical application.

  • PDF

On the Crystal Growth of Gap by Synthesis Solute Diffusion Method and Electroluminescence Properties. (합성용질확산법에 의한 GaP결정의 성장과 전기루미네센스 특성)

  • Kim, Seon-Tae;Mun, Dong-Chan
    • Korean Journal of Materials Research
    • /
    • v.3 no.2
    • /
    • pp.121-130
    • /
    • 1993
  • The GaP crystals were grown by synthesis solute diffusion method and its properties were investigated. High quality single crystals were obtained by pull-down the crystal growing ampoule with velocity of 1.75mm/day. Etch pits density along vertical direction of ingot was increased from 3.8 ${\times}{10^4}$c$m^{-2}$ of the first freeze to 2.3 ${\times}{10^5}$c$m^2$ of the last freeze part. The carrier concentration and mobilities at room temperature were measured to 197.49cc$m^2$/V.sec and 6.75 ${\times}{10^{15}}$c$m^{-3]$, respectively. The temperature dependence of optical energy gap was empirically fitted to $E_g$(T)=[2.3383-(6.082${\times}{10^{-4}}$)$T^2$/(373. 096+TJeV. Photoluminescence spectra measured at low temperature were consist with sharp line-spectra near band-gap energy due to bound-exciton and phonon participation in band edge recombination process. Zn-diffusion depth in GaP was increased with square root of diffusion time and temperature dependence of diffusion coefficient was D(Tl = 3.2 ${\times}{10^3}$exp( - 3.486/$k_{\theta}$T)c$m^2$/sec. Electroluminescence spectra of p-n GaP homojunction diode are consisted with emission at 630nm due to recombination of donor in Zn-O complex center with shallow acceptors and near band edge emission at 550nm. Photon emission at current injection level of lower than 100m A was due to the band-filling mechanism.

  • PDF

Fabrication of $Li_2B_4O_7$ Series Single-Crystal TLDs and their TL properties ($Li_2B_4O_7$ 계열 단결정 TLD 소자의 제작과 특성)

  • Park, Myeong-Hwan;Park, Kang-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • High-quality single crystals of pure $Li_2B_4O_7$ as well as $Li_2B_4O_7$ doped with Cu, Mn and Mg impurities (1.0mol%, respectively) have been grown from the melt of $Li_2CO_3+2B_2O_3$ by Czochralski method in platinum crucibles. To study the thermoluminescent properties, $Li_2B_4O_7$ series single crystal TLDs were made by cutting in the size of $4{\times}5{\times}1\;mm^3$. The glow curves show two or three peaks which can be easily deconvoluted. It is observed that room temperature($20{\sim}30^{\circ}C$) fadings of the dosimetric peaks of $Li_2B_4O_7$ series single crystal TLDs were about 10 % for 30 days. The relative photon energy response for $Li_2B_4O_7$ series single crystal TLDs were about 85 % when the responses were normalized to that measured with $^{60}Co\;(1.25\;MeV)\;{\gamma}-rays$. The measured data are in a good agreement with theoretical ones. The $Li_2B_4O_7$ series single crystal TLDs fabricated in this work can be used for monitoring personal and environmental radioactivity.

  • PDF

A Study on the Reduction of Absorbed Dose through the Insertion of a Shielding Material in the Intraoralsensor of Dental Radiography (치과 방사선촬영 시 구내 센서 내 차폐체 삽입을 통한 피폭선량 감소 연구)

  • Kim, A Yeon;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.273-279
    • /
    • 2022
  • In order to reduce the absorbed dose given to the patient during dental radiography, a sensor that inserts a shield into the intraoralsensor was designed. Using the designed sensor, the change in absorbed dose depending on whether or not a shield was used was evaluated. The system used to evaluate the absorbed dose is VEX-S300C from Vatech, and the energy spectrum of X-rays was obtained through SPEKTR simulation based on the irradiation conditions of 65 kV, 3 mA, and 0.15 sec, and the number of photons for each energy was derived. After designing the system through Genat4 Application for Tomographic Emission(GATE) simulation, the energy spectrum obtained was used as a radiation source to calculate the absorbed dose. Lead was used for the shield, and simulations were performed at 0.1 mm thickness intervals from 0.1 mm to 0.5 mm was evaluated. In the case of using an X-ray field with a diameter of 60 mm, the decrease in absorbed dose according to the presence or absence of a shield decreased exponentially as the thickness of the shield increased. In addition, when a 20 mm × 30 mm field was used, the absorbed dose was significantly reduced even when no shield was used, and it was confirmed that the absorbed dose was further reduced when a shield was used.

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Determination of the Phantom Scatter Factor ($S_P\;Factor$) using a small Block in the Phantom (작은 블럭을 이용한 판톰 내에서의 판톰 산란 인자(Sp Factor)측정법)

  • Yi Byong Yong;Hong Seok Min;Kim Jae Sung;Choi Eun Kyung;Chang Hyesook;Lee Myung Za;Chun Ha Chung
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.121-123
    • /
    • 1992
  • New measurement method for $S_{p}$ factors (Phantom Scatter Factors) is presented. The theoretical development of the approach is disscused showing that $S_{p}$ factors can be obtained from three measurements of ionnization in a blocked, reference field and open field. This method has been tested using $^{60}Co$ gamma rays. The results were within 1% deviation between the theory and the experiment for the $S_{p}$ factor. The new method does not need air measurement, and we could could determine the $S_P$ factors with a small piece of block

  • PDF

A Study of Performance Characteristics for Electronic Personal Dosimeters in Photon and Electron Radiation Field (광자 및 베타 방사선에 대한 전자개인선량계의 성능특성연구)

  • Kim, Hyun-Ki;Kim, Bong-Hwan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.85-95
    • /
    • 1997
  • TLD and film badges have been traditionally used as formal dosimeters in personal monitoring and are still most widely used. Recently, electronic personal dosimeters based upon Si diode or miniature G-M tube were developed and are getting attractions due to their merits of active nature ; indication of dose rates and the commutative dose, and facilitation of record keeping and radiological control. Response characteristics of the electronic dosimeters including reproducibility, accuracy, linearity, energy and angular dependencies, detection threshold, and response time were examined for three commercial types ; EPD2, STEPHEN6000, and PD-3i. The results were compared with the relevant requirements of IEC standards and Ontario Hydro standards to conclude that their general performances were good. Some specific deficiencies, e.g. incapability of shallow dose measurement of STEPHEN6000, and PD-3i, however, should be corrected to be used as a formal dosimeter.

  • PDF

Stem Effect Correction Factor of Ionization Chamber in Exposure Measurements of High Energy Photons (고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수)

  • Park, Cheol-Woo;Lee, Jae-Seung;Kweon, Dae-Chel;Cha, Dong-Soo;Kim, Jin-Soo;Kim, Kyoung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.

  • PDF

Picosecond Fluorescence Lifetimes of Hematoporphyrin Derivatives in Solutions and in vitro (용액 및 시험관 실험에서의 헤마토포르피린 유도체 분자의 피코초 형광수명시간 분석)

  • Kim, Hyun-Soo;Chu, Sung-Sil;Kim, Gwi-Eon;Lee, Won-Young;Kim, Ung
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.61-70
    • /
    • 1995
  • The picosecond time resolved fluorescence spectra of Hematoporphyrin Derivative (HPD) in both solutions and cancer cell are measured by a time correlated single photon counting system with a synchronously mode locked dye laser. Two exoponential decay components in the fluorescence spectra were observed. The slow decay(6.3 ㎱)and the fast one(350 ㎰)are attributed to be originated from monomers and dimers, respectively. The absorption and fluorescence measurements in steady state also showed the presence of a monomeric and dimeric forms of HPD molecules. The monomer lifetime in the cancer cell was measured to be longer than that in solution, which was expected from the blue shift and narrowing of the absorption spectra for HPD-treated in vitro. The relative amplitude of the fast component was found to be enhanced in cancer cell, strongly indicating the higher affinity of the dimer for the cancer cell.

  • PDF