• Title/Summary/Keyword: 광와동

Search Result 54, Processing Time 0.017 seconds

THE EFFECT OF LIGHT CURING METHODS AND RESIN ADHESIVES ON THE MICROLEAKAGE OF RESTORATIONS IN PRIMARY TEETH (광중합 방법 및 레진 접착제의 종류에 따른 유치 수복물의 미세누출)

  • Jeong, Young-Nam;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.592-599
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the effects of several light curing methods and several adhesives on the microleakage of composite resin restorations in primary teeth. Materials and methods : In 150 extracted human primary anterior teeth, O-shaped cavities were prepared in the labial surface ; the cavity diameter and depth were 1.6mm. The cavities were filled with light-activated composite resin, Compoglass. Four kinds of adhesives were used. Each filling materials were polymerized with three light cure methods. The restorations were polished using Sof-Lex discs(3M Co., USA). The samples were thermocycled 1,000 times between $5^{\circ}C$ and $55^{\circ}C$ with a 1-minute dwell time. Then, they were immersed in a 2% methylene blue solution(pH 7) for 12hours. Subsequently they were sectioned labio-lingually through the center of the restoration with a diamond saw at low speed with a water coolant, and evaluated by stereomicroscopy. Microleakage analyses were done, using scores from 0 to 4. Results : Results showed the least microleakage in Compoglass group(P<0.05). There were less microleakage in SBMP group among the adhesive groups, but no significant difference was observed(P>0.05). And there were no significant differences among the groups depending on curing methods(P>0.05).

  • PDF

Interfacial fracture analysis of human tooth/composite resin restoration using acoustic emission (음향방출법을 이용한 치아/복합레진 수복재의 계면부 파괴해석)

  • Gu, Ja-Uk;Choi, Nak-Sam;Arakawa, Kazuo
    • Composites Research
    • /
    • v.22 no.6
    • /
    • pp.45-51
    • /
    • 2009
  • The marginal integrity at the composite resin-tooth interface has been analyzed in real time through acoustic emission (AE) monitoring during the polymerization shrinkage of composite resin subjected to the light exposure. It was found that AE signals were generated by the polymerization shrinkage. Most AE hit events showed a blast type signal having the principal frequency band of 100-200kHz. Bad bonding states were indicated by many hit events in the initial curing period of 1 minute with high contraction rate. The quantity of hit events for the human molar dentin specimen was much less than that for the steel ring specimen but more than that for the PMMA ring specimen. The better the bonding state, the less the AE hit events. The AE characteristics were related with the tensile crack propagation occurring in the adhesive region between the composite resin and the ring substrate as well as the compressive behavior of the ring substrate, which could be used for a nondestructive characterization of the marginal disintegrative fracture of the dental restoration.

THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS (법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향)

  • Koo, Bong-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.452-459
    • /
    • 2006
  • Competition will usually develop between the opposing walls as the restorative resin shrinks during polymerization. Magnitude of this phenomenon may be depended upon cavity configuration and volume. The purpose of this sturdy was to evaluate the effect of cavity configuration and volume on microleakage of composite resin restoration that has margins on the enamel site only. The labial enamel of forty bovine teeth was ground using a model trimmer to expose a flat enamel surface. Four groups with cylindrical cavities were defined, according to volume and configuration factor(Depth x Diameter / C-factor) - Group I : 1.5 mm ${\times}$ 2.0 mm / 4.0, Group II : 1.5 mm ${\times}$ 6.0 mm / 2.0, Group III : 2.Omm ${\times}$ 1.72 mm / 5.62, Group IV : 2.0 mm ${\times}$ 5.23 mm / 2.54. After treating with fifth-generation one-bottle adhesive - BC Plus$^{TM}$ (Vericom, AnYang, Korea), cavities were bulk flted with microhybrid composite resin - Denfill$^{TM}$ (Vericom). Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Specimens were thermocycled 500 times between 5$^{\circ}$C and 55$^{\circ}$C for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}$A) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. The results were as follows: 1. Small cavity volume showed lower microleakage score than large one, however, there was no statistically significant difference. 2. There was no relationship between cavity configuration and microleakage. Factors of cavity configuration and volume did not affect on microleakage of resin restorations with enamel margins only.

A STUDY OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO FILLING METHODS USING STRAIN GAUGE (스트레인 게이지를 이용한 적층방법에 따른 복합레진의 중합수축에 관한 연구)

  • Kim, Eung-Hag;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.18-29
    • /
    • 2008
  • The purpose of this study was to compare the polymerization shrinkage of several filling methods using strain gauges. In this study, a light-emitting diode(LED) curing unit(Elipar Freeligh2, 3M EPSE, USA) and plasma arc lamp(PAL) curing unit(Flipo, LOKKI, France) were used for curing, Filtek $Z350^{TM}$(3M EPSE, USA) composite resin was used for the cavity filling. Sixty permanent bicuspid teeth, that were extracted for orthodontic treatment, were studied. The cavities were prepared on the occlusal surface and were filled using the following methods : 1) bulk filling, 2) parallel filling, 3) oblique filling The strain was recorded on the buccal, lingual, mesial and distal surfaces and the strain values were computed into stress values. The shear bond strength of each filling method was tested using a Micro Universal Testing machine. The results can be summarized as follows: 1. In the strain changes, all LED and PAL curing groups showed an increase on the buccal surface and a slow decrease as time elapsed. 2. In the strain changes of the mesial and distal surfaces, the decreases and increases were shown repeatedly and reduced as time elapsed. 3. There were no significant statistical strain changes among filling methods in the LED or PAL curing groups. 4. There were significant statistical strain changes between the LED and PAL curing groups on the buccal surface(p<0.05). 5. From the shear bond strength results, in the LED curing group, filling method 3 showed lower surface stress than filling method 1 and 2(p<0.05). In the PAL curing group, there were no significant statistical strain changes between each filling method. 6. The surface stress of each group was lower than the shear bond strength.

  • PDF

EFFECT OF BISCOVER ON THE MARGINAL MICROLEAKAGE OF COMPOSITE RESIN RESTORATION (복합레진 수복물의 변연 미세누출에 관한 BiscoverTM 전색제의 효과)

  • Cho, Young-Gon;Choi, Hee-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.355-362
    • /
    • 2005
  • The purpose of this study was to compare the effect on marginal leakage of a resin surface sealant (Biscover) applied before or after polymerization of composite resin to unsealed composite restorations. Thirty Class V cavities with the occlusal margin in enamel and cervical margin in dentin or cementum were prepared on the buccal surfaces of sound extracted molars and restored with a microfilled light-cured composite resin (Micronew). Restorations were randomly assigned into one of three equal groups (n = 10): a control group - no surface sealing, group 1 - applied Biscover after polymerization of the composite resin. and group 2 - applied Biscover before polymerization of the composite resin. Specimens were thermocycled, immersed in a $20\%$ methylene blue solution for 4 hoots, sectioned longitudinally, and analyzed for leakage at the occlusal and gingival margins. The results of this study were as follows 1. In sealed group, group 2 showed higher microleakage than group 1 at both occlusal and gingival margins. but there was no significant difference between two groups (p > 0.05). 2. Unsealed control group showed a little higher microleakage than sealed group at occlusal margins, and a little Higher or similar microleakage than sealed group at gingival margins (p > 0.05) 3. Control group and group 2 showed significantly less microleakage at the occlusal margins, but group 1 showed no significantly difference between microleakage at the occlusal and gingival margins.

EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS (삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향)

  • Kim, Yong-Hee;Park, Jae-Gu;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.327-334
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of burs on microleakage of Class V resin restorations when a self-etching primer adhesive was used. Forty Class V cavities were prepared with four different cutting burs on extracted third molars, and divided into one of four equal groups (n = 10); Group 1-plain cut carbide bur (no. 245), Group 2-cross cut carbide bur (no. 557), Group 3-fine diamond bur (TF-21F), Group 4-standard diamond bur (EX-41). The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. Cavities were treated with Clearfil SE Bond and restored with Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. The results of this study were as follows; 1. At enamel margin, microleakage of group 4 was statistically higher than those of group 1, 2 and 3 (p < 0.01). 2. At dentinal margin, microleakage of group 4 was statistically higher than group 3 (p < 0.01), but group 1 and 2 were not statistically different with group 3 and 4. 3. Enamel microleakage was statistically higher than dentinal microleakage in group 1, 2 and 3 (p < 0.05), but statistical difference between the microleakage of enamel and dentinal margin was not in Group 4. In conclusion, the use of coarse diamond bur showed high microleakage at both enamel and dentinal margin when Clearfil SE Bond was used in class V cavity.

THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES (1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과)

  • Baek, Shin-Young;Cho, Young-Gon;Song, Byeong-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.428-434
    • /
    • 2008
  • The purpose of this study was to compare the microtensile bond strength in Class I cavities associated with different light curing modes of same light energy density. Occlusal enamel was removed to expose a flat dentin surface and twenty box-shaped Class I cavities were prepared in dentin. Single Bond (3M Dental product) was applied and Z 250 was inserted using bulk technique. The composite was light-cured using one of four techniques, pulse delay (PD group), soft-start (SS group), pulse cure (PC group) and standard continuous cure (CC group). The light-curing unit capable of adjusting time and intensity (VIP, Bisco Dental product) was selected and the light energy density for all curing modes was fixed at $16J/cm^2$. After storage for 24 hours, specimens were sectioned into beams with a rectangular cross-sectional area of approximately $1mm^2$ Microtensile bond strength $({\mu}TBS)$ test was per- formed using a univel·sal testing machine (EZ Test, Shimadzu Co.). The results were analyzed using oneway ANOVA and Tukey's test at significance level 0.05. The ${\mu}TBS$ of PD group and SS group was higher than that of PC group and CC group. Within the limitations of this in vitro study, modification of curing modes such as pulse delay and soft start polymerization can improve resin/dentin bond strength in Class I cavities by controlling polymerization velocity of composite resin.

MICROLEAKAGE IN RESIN COMPOSITE POLYMERIZED WITH VARIOUS LIGHT CURING UNITS (수종의 광중합기에 의한 복합레진 중합시 미세누출에 관한 연구)

  • Park, Sung-Jin;Kim, Dae-Eup;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.604-610
    • /
    • 2005
  • This study was to evaluate the effects of several light curing units on the microleakage of composite resin restorations in primary teeth. The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Filpo) low heat plasma arc light(Aurys) and high intensity LED(Freelight 2). After preparing cavities on sound primary teeth, cavities were filled with composite resin(Z100) using the same resin bond agent(Scotchbond Multi-Purpose) and were cured with each curing light system. After storing each specimen in sterile water for 24 hours, thermal circulation was done 1,000 times followed by pigmentation using 2% methylene blue solution. Each specimen was sliced and the degree of pigmentation was graded. When microleakage is graded, the average of Aurys was 0.95 which was the lowest and Freelight 2(1.05), Filpo(1.25), Optilux 360(1.30) followed. But values were not shown statistically significant difference (P>0.05). The results suggest that the newly developed curing units which has advantage in children by decreasing discomfort and procedure time can increase the microleakage of the composite resin.

  • PDF

THE ADAPTIBILITY OF LIGHT-CURED GLASS-IONOMER CEMENTS TO CAVITY WALLS. (와동벽에 대한 광중합형 글래스아이오노머 시멘트의 적합도)

  • Kang, Mi-Sun;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.173-182
    • /
    • 1995
  • The purpose of this study was to evaluate the adaptability of light-cured glass ionomer cement to cavity walls. Class V cavities were prepared on the labial surfaces of extracted bovine incisor teeth. The cavities were restored with Fuji II as self-cured glass ionomer cement and Fuji II LC, Vitremer as light-cured glass ionomer cement. Fluorescent markers (fluoreceine and rhodamin B) were incorperated into liquid and primer for a better image of microscopic observation. Restored teeth were sectioned by longitudinal and labiolingual direction. The adaptability at the tooth-restoration interface was assessed incisally, axially and cervically by confocal scanning laser microscope. Following results were obtained : 1. Chemical-cured glass iomomer cement restoration showed close adaptation on the all of the cavity walls, but, cracks formed within the cement. 2. Light-cured glass ionomer cement restoration was well adapted to the cavity walls, but showed crack in the cement adjacent to axial dentinal wall. 3. There' was no significant difference in adaptability between two light-cured glass ionomer cement restorations.

  • PDF

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).