The Study on the Emission Characteristics of Particulate Matters from Meat Cooking (고기구이에서 발생하는 입자상물질의 배출특성에 관한 연구)

  • Bong, C.K.;Park, S.J.;Park, S.K.;Kim, J.H.;Hwang, Y.H.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.196-201
    • /
    • 2011
  • Emission from meat cooking may contribute to the concentration of the Particulate Matters(PM) in the city. This study is to investigate the particle size and the emission characteristics of particulate matters from pork and beef cooking. The chamber was installed for sampling of PM generated from pork belly and beef sirloin cooking including seasoned ones. Cascade Impactor and Portable Aerosol Monitor (PAM) were used to analyse the particle size distribution. At the result of the Cascade Impactor sampling, particulate matters from the pork cooking was higher than that of beef. The gravimetric concentration of PM according to the size was highest at the range of $1.95{\sim}3.2{\mu}m$ and the gravimetric concentration of PM from the non-seasoned meat was higher than that of the seasoned one. The emission factors from pork, pork seasoned, beef and beef seasoned were 1.36 g/kg, 1.03 g/kg, 1.23 g/kg, 0.92 g/kg respectively. To see the result of PAM sampling, the ranges of $1.6{\sim}2.5{\mu}m$ and $2.5{\sim}3.5{\mu}m$ were reveled as highest. The ration of $PM_{2.5}/PM_{10}$ from pork and beef was 0.56~0.58. The emission factors from pork, pork seasoned, beef and beef seasoned measured by PAM were revealed as 3.37 g/kg, 2.76 g/kg, 2.93 g/kg, 2.77 g/kg respectively.

Implementation of Particle Measuring Sensor System Using Laser Optical Scattering Method (레이저 광산란식 미세먼지 측정 시스템의 실현)

  • Kim, Gyu-Sik;Na, Hyeong-Uk;Kang, Sang-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.365-366
    • /
    • 2008
  • 광학입자 계수기는 실내환경, 대기오염 및 콜린룸 등 입자크기분포 측정장비로 가장 많이 사용된다. 광학입자 계수기에 샘플링된 업자는 관측체적 내로 1개씩 통과 하며 산란된 빚은 집광장치에 의해 광검출기로 전달한다. 이때 산란광의 양에 비례하여 전압 (전류)의 세기로 변환하여 전기적 선호로서 나타나는 Pulse의 높이는 Calibration Data에 따라 업자의 크기로 변환하고 Pulse의 개수는 입자의 개수로 표시된다. 입자의 크기와 개수등 이용하여 부피로 환산 한 후 부유하는 입자의 평균 밀드를 이용하여 질량으로 환산시킨다. 이렇게 측정된 미세먼지 농도는 ZigBee 통신을 사용하여 구축한 시스템을 통해서 중앙부에서 실시간으로 먼지 농도를 알 수 있다. 특히 멀티흡 기능을 이용하여 건물 구조가 복잡하거나 층간의 통신, 꺾인 부분이나 사무실 안과 밖과 같은 무선 통신이 원할 하지 못하는 경우를 극복하여 미세먼지의 농도 값을 측정 할 수도 있다.

  • PDF

Development of Particle Counter with wireless FMS (무선 FMS를 지원하는 초미세 입자 계수기 개발)

  • Ku, Ja-Yl;Jun, Sung-Don
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.63-66
    • /
    • 2010
  • 기존의 입자계수기(Particle Counter)는 0.3um의 최소 인식 크기와 샘플링 유량이 2.83 lpm을 갖는다. 본 논문에서는 0.1um의 최소 인식 크기와 샘플링 유량이 28.3lpm과 50lpm을 갖는 입자 계수기를 개발하였다. 이와 함께 온도, 습도, 정전기를 실시간으로 측정하여, 이를 무선 인터페이스를 통해서 모니터링 프로그램과 연동, DB화하여 크린룸 현장의 환경을 실시간으로 유지 관리하도록 하였다.

  • PDF

Implementation of Indoor Air Quality Monitoring System for Subway Stations (지하철 역사 공기질 모니터링 시스템의 구현)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.294-301
    • /
    • 2013
  • The particle matter concentrations in the subway stations should be monitored and controlled for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the cheap instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, a monitoring system is implemented to display and record the data of $PM_{10}$, $CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, CDMA M2M wireless communication method is applied.

Reference-based Calibration Method for Sensor Error of Oil Mist Detection System (Reference 기반 오일 미스트 검출 센서 오차 최소화 보정 방법)

  • Kim, Se-Jin;Jeon, Sang-Wook;Park, Ju-Won;Jung, So-Young;Kim, Young-Tak;Lee, Young-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.11a
    • /
    • pp.94-95
    • /
    • 2011
  • 선박 엔진 크랭크 케이스 내부의 기계 결함으로 발생하는 윤활 오일 미스트 발생은 폭발뿐만 아니라 급격한 온도와 압력상승으로 2차 폭발을 야기하는 등 큰 피해를 가져와 현재 선박용 엔진의 크랭크 케이스에 오일미스트 검출장치의 설치를 의무화 하고 있는 추세이다. 본 논문에서는 이러한 피해를 줄이기 위하여 광 산란 방식을 이용한 오일 미스트 검출장치를 구현하였으며, 구현된 오일미스트 검출 장치의 오일미스검출 센서 센싱 성능은 전기적, 광학적 그 외 환경적 요인으로 인하여 출력값이 일정하지 못해 각각의 오일미스트 검출 센서를 보정해야 한다. 본 논문에서는 크랭크케이스마다 장착되는 오일미스트 검출 센서의 오차를 최소화하기 위하여 정밀하게 Calibration된 Reference Data를 기반으로 최소자승법을 적용하여 센서를 Calibration하였으며, 그 결과 각각의 오일미스 검출센서의 오차를 기존 방법과 비교하여 최소화할 수 있었다.

  • PDF

Environmental Sensor Monitoring System of Subway Stations Using USN (USN을 이용한 지하철 역사 대기환경 모니터링 시스템)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • The$PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, an USN monitoring system is implemented to display and record the data of $PM_{10}$, CO/$CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, 2.4GHz Zigbee, 424MHz wireless communication, and CDMA M2M method are applied and evaluated.