• Title/Summary/Keyword: 광도법

Search Result 192, Processing Time 0.03 seconds

A Bioassay for Chemicals Affecting Plant Pigment Biosynthesis: Greening Assay (식물색소 관여형 화합물의 생물검정법으로서 Greening Assay)

  • Kim, J.S.;Kim, T.J.;Hong, K.S.;Hwang, I.T.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.10 no.3
    • /
    • pp.214-220
    • /
    • 1990
  • To establish a greening assay for screening, and physiological and biochemical studies of the compounds affecting biosynthesis of plant pigments, were conducted on environmental factors, and on ways of incubation and illumination which affect plant greening. Greening was good when both cucumber and barley were grown for 5 to 6 days at $25^{\circ}C$ in darkness, when adaxial sides of cucumber cotyledons were contacted with the solution, and when barley leaf fragments were taken 0.5 to 2.0cm from the leaf tip. Potassium phosphate buffer(pH 6.0) at 10mM was most desirable for plant greening. The speed of greening during illumination was increased as the temperature increased from $15^{\circ}C$ to $35^{\circ}C$. The responses were sensitive more in cucumber than in barley, and in chlorophyll biosynthesis than in carotenoid biosythesis. The content of chlorophyll was greatest at the light intensity of 5000 and 1000 lux for cucumber and barley, respectively, but the biosynthesis of carotenoids were greatest at the light intensity higher than for chlorophyll. In use of solvents for dissolving chemicals, acetone, ethyl alcohol and DMSO at 10, 0.1 and 2.5% or less, respectively, did not affect the biosynthesis of plant pigments. $pI_{50}$ values were calculated for chemicals affecting pigment biosynthesis.

  • PDF

The Evaluation and Fabrication of Photoconductor Sensor for Quality Assurance of Radiation Therapy Devices (방사선치료기기 정도관리를 위한 광도전체 센서 제작 및 평가)

  • Kang, Sang Sik;Noh, Sung Jin;Jung, Bong Jae;Noh, Ci Chul;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.565-569
    • /
    • 2016
  • Recently, a use of linear accelerator with a multi-leaf collimator(MLC) for radiation therapy is increasing. The importance of quality assurance (QA) for the linear accelerator is emphasized as the side effects of the inaccurate delivery of the radiation beam has been increased according to the high dose irradiation technique. In this study, The $HgI_2$ and $PbI_2$ photoconductor layer samples of $400{\mu}m$ thickness were fabricated using sedimentation method among particle-in-binder technology. From the fabricated samples, the electrical properties(dark current, output current, response properties and linearity) were investigated. From the experimental results, $HgI_2$ has good charge signal generation and linearity. Finally, from the signal response results about various thickness of $HgI_2$ sensor, the signal creation efficiency of $400{\mu}m$ thickness of $HgI_2$ sensor has the highest value and the excellent reproducibility below ${\pm}2.5%$.

Transport Properties of Charge Carrier in Amorphous Selenium Converter drived by Vacuum Thermal Evaporation Method (진공증착법을 이용한 비정질 셀레늄 변환체의 전하캐리어 이동특성 분석)

  • Park, Ji-Koon;Choi, Il-Hong;Lee, Mi-Hyun;Lee, Kwang-Phoo;Yu, Haeng-Soo;Jung, Bong-Zae;Kang, Sang-Sik;Kim, Mi-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.37-40
    • /
    • 2010
  • In this paper, transport properties of charge carrier which is produced by x-ray exposure were investigated.. It is the research of charge transport and specific property of trap that is performed in direct digital x-ray image receptor. We measured transit time and drift mobility of charge carriers of a-Se photoconductor using time-of-flight method. We made a testing glass with a-Se of $100{\mu}m$ thickness on corning glass using thermal evaporation method. As a result of this experiment, electron and hole transit time was each $229.17{\mu}s$ and $8.73{\mu}s$ at $10V/{\mu}m$ electric field and drift mobility was each $0.00174cm^2/V{\cdot}s$, $0.04584cm^2/V{\cdot}s$. But the results shows us different measurement value of electron and charge drift mobility and it was investigated about charge transport properties and trap mechanism.

Optimized Processing Condition of Production of Nannochloropsis oculata under Light-emitting Diode (LED) Condition (LED배양조건에서 미세조류 Nannochloropsis oculata의 생산 효율성을 높이는 공정 최적화)

  • Lee, Nam Kyu
    • Journal of Life Science
    • /
    • v.27 no.7
    • /
    • pp.754-759
    • /
    • 2017
  • The 100 l culture system was made on the basis of LED light, and Nannochloropsis oculata was cultured in f/2 medium at light intensity ($100{\mu}mol/m^2/s$), culture temperature ($20^{\circ}C{\pm}1^{\circ}C$) and LD cycle (12hr). As a result, the maximum biomass of 1.07 g/l was cultured as a result of 100 l mass culture at $100{\mu}mol/m^2/s$ and 24 mg/l nitrate concentration in LED blue (475 nm). The extraction was carried out using sonicator, homogenizer and chemical method 0.5M HCl shredding method. The contents of chlorophyll a, chlorophyll b and carotenoid were 1.6, 0.5 and 0.3 mg/g cell. When using homogenizer, it was measured at 1.0, 0.6 and 0.2 mg/g cell. The chemical breakdown method of 0.5M HCl, chlorophyll a, b, and carotenoid contents were measured as 0.9, 0.8, 0 mg/g cell. The highest amount of biomass during the distruption time was measured at 3.6 mg/g cell at 15 min disintegration and acetone, 3.6 mg/g cell of acetone, methanol, and ethanol were measured as effective solvents. Concentration was measured by using microfilter, disk type continuous centrifuge and tubular type continuous centrifuge were 16.0, 1.1 and 0.5 g/l, respectively. Four kinds of equipment such as hot air dryer, vacuum dryer, spray dryer and freeze dryer were tested to optimize the drying process. As a result, the recovery rates of spray dryer and freeze dryer were 80% and 60%.

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

A Study on the Growth Analysis of Pinus koraiensis Seedings under Various Relative Light Intensities and Planting Densities (잣나무 묘목(苗木)의 생육환경(生育環境) 요인(要因)에 따른 생장해석적(生長解析的) 연구(硏究))

  • Kim, Young Chai
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.3
    • /
    • pp.314-322
    • /
    • 1989
  • For the improvement of nursery condition and the study of eco-physiological characteristics of Pinus koraiensis(2-2) seedlings, the primary productivity was investigated and the growth characteristics and their correlationship were analyzed from May to September in 1987. Seedlings used in this study were grown at the nursery of Experimental Forestry of Kyung Hee Univ. The installation of experimental plots were divided into control plot (100%), 63%, 37% and 19% relative light intensity, and each relative light intensity plots were split into $15{\times}15/m^2$, $12{\times}12/m^2$, $9{\times}9/m^2$ and $6{\times}6/m^2$ plnting density by randomized black design method. To take into account the edge effect of plant population, material were selected from each plot by random sampling at 30 days interval. Each sampled material was divided into leaf and stem drived in a drying oven at the temperature of $85^{\circ}C$ until it had constant weight and weighed. and leaf area was surveyed. Growth analysis for RGR and NAR was done by Blackman method and correlation coefficient were investigated between RGR and NAR by analyzing the dry matter production and growth characteristics of the material, cultivated on the experimental nursery under the condition of different treatment the obtained result were as follows : 1. The increasing rate of dry matter was similar at early stage of growth, but not at late stage. 2. Leaf area growth was the maximum value at 63% relative light intensity and the minimum at 19% RLI 3. The value of RGR was the highest on June under $6{\times}6/m^2$ planting density in 63% relative light intensity, the lowest on September under $12{\times}12/m^2$ of 19% relative light intensity. 4. The change NAR decreased in early stage of growth, while it increased on August and September, The value of RGR on June under $6{\times}6/m^2$ planting density in 100 light intensity was the highest, and on September under $12{\times}12/m^2$ planting density in 19% relative light intensity was the lowest. 5. Regression and correlation between RGR and NAR showed significantly positive.

  • PDF

Spectrophotometric microtitre assay for rapid screening of membrane-disrupting herbicides (분광분석을 이용한 막과산화작용 제초제의 신속한 검정법)

  • Kwon, Ok-Kyung;Cho, Kwang-Yun;Kim, Jin-Seog
    • The Korean Journal of Pesticide Science
    • /
    • v.4 no.1
    • /
    • pp.11-18
    • /
    • 2000
  • This study was conducted to establish an efficient screening method of membrane-disrupting herbicides, based on the result that membrane leakage leading to evolution of carbonyl compounds and aldehydes could be colorimetrically assessed by formation of stable chromophores with MBTH and ferric chloride. Assay conditions including plant material, light intensity, irradiation time, concentrations of reagents for colorization, and reaction time were optimized, and activities of different types of known herbicides were investigated with cucumber cotyledon discs. That result indicated that this assay was sensitive to membrane-disrupting herbicides, such as protoporphyrinogen oxidase inhibitors (acifluorfen, oxyfluorfen, oxadiazon) and an electron interceptor from photosystem I(paraquat). With seven compounds newly synthesized, highly positive correlation was observed between herbicidal activities measured by greenhouse bioassay and MBTH method. Because only a single disc(4 mm diameter) from cucumber cotyledon in 60 ${\mu}L$ of incubation solution was required to assay, a large number of herbicides could be tested simultaneously using 96-well microtitre plates. But the assay efficiency is not likely to significantly increase because of the boiling step during the reaction.

  • PDF

On Board Comparison of Total Hydrogen Ion Concentration (pH) and Total Alkalinity Measurements in Seawater (해수의 총수소이온농도(pH)와 총알칼리도 측정방법에 대한 선상 비교 연구)

  • Kang, Dong-Jin;Tishchenko, Pavel Ya;Kahng, Sung-Hyun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.205-211
    • /
    • 2011
  • On board comparison of pH and total alkalinity measurement in seawater was carried out during the JES expedition on R/V Roger Revelle in the East Sea using 550 real seawater samples from the surface to the bottom. Spectrophotometry and potentiometry without liquid junction were compared for pH measurement. The pH values of two methods are generally in a good agreement. Spectrophotometry with a pipette provides higher value compare with the potentiometry in the deep layer, where pH values are lower. However, spectrophotometry without a pipette shows same values with potentiometry within their precision range. The pipetting procedure may remove of $CO_2$ in the sample, which causes increase of pH. Potentiometric titration methods using a closed-cell and an open-cell were compared for the total alkalinity measurement. Values from open cell method are smaller by about 5~10 ${\mu}mol\;kg^{-1}$ than those from closed cell method. This may be caused by the bubble formed in the closed cell during the experiment. Although any analytical method compared in this study for the pH or TA measurement can be applied, special attentions should be paid for satisfactory results.

Study on Improvement of Signal to Noise Ratio for HgI2 Radiation Conversion Sensor Using Blocking Layer (Blocking layer 적용을 통한 HgI2 방사선 변환센서의 신호대 잡음비 향상에 관한 연구)

  • Park, Ji-Koon;Yoon, In-Chan;Choi, Su-Rim;Yoon, Ju-Sun;Lee, Young-Kyu;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

Quantitative Analysis of Acid Value, Iodine Value and Fatty Acids Content in Sesame Oils by NIRS (근적외선분광광도법을 이용한 참기름의 산가, 요오드가, 지방산정량법에 관한 연구)

  • Kim, Jae-Kwan;Lee, Myung-Jin;Kim, Myung-Gill;Kim, Kyung-A;Park, Eun-Mi;Kim, Young-Sug;Ko, Hoan-Uck;Son, Jin-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.204-212
    • /
    • 2006
  • This study was conducted to investigate the possibility of rapid and non-des tructive evalution of AV (Acid Value), IV (Iodine Value) and fatty acids in sesame oils. The samples were scanned over the range $400\sim2500nm$ using transmittance spectrum of NIRS(Near-infrared spectroscopy). A calibration equation calculated by MPLS regression technique was developed and correlation coefficient of determination for AV, IV, palmitic acid, stearic acid, linoleic acid and linolenic acid content were 0.9907, 0.9677, 0.9527, 0.9210, 0.9829, 0.9736 and 0.9709 respectively. The validation model for measuring the AV content had R of 0.989, SEP of 0.058 and IV content had R of 0.944, SEP of 0.562 and palmitic acid content had R of 0.924, SEP of 0.194 and stearic acid content had R of 0.717, SEP of 0.168 and oleic acid content had R of 0.989, SEP of 0.221 and linoleic acid content had R of 0.967, SEP of 0.297 and linolenic acid content had R of 0.853, SEP of 0.480 by MPLS. The obtained results indicate that the NIRS procedure can potentially be used as a non-destructive analysis method for the purpose of rapid and simple measurement of AV, IV and fatty acids in sesame oils.