Fluid Flow in the Fluidized Bed Shell and Tube Type Heat Exchanger with Corrugated Tubes (파형관 튜브가 있는 순환유동층 원통다관형 열교환기 내의 유체유동)

  • 안수환;이병창;배성택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.406-412
    • /
    • 2003
  • An experimental study was carried on the characteristics of fluid flow and heat transfer in a fluidized bed shell-and-tube type heat exchanger with corrugated tubes. Seven different solid particles having same volume were circulated in the tubes. The effects of various parameters such as water flow rates, particle geometries and materials, and geometries of corrugated tubes on relative velocities and drag coefficients were investigated. The present work showed that the drag force coefficients of particles in the corrugated tubes were usually lower than those in the smooth tubes, meanwhile the relative velocities between particles and water in the corrugated tubes were little higher than those in the smooth tubes except the glass.

A Study on Fluid Flow of Various Viscosities in Coronary Artery (관상동맥 분지관에서 점도에 따른 유체의 유동현상 연구)

  • An, Gi-Yeong;Lee, Hyeon-Seop
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.403-408
    • /
    • 2013
  • 본 논문은 EDISON_CFD를 이용하여 관상동맥 분지관에서 점도에 따른 유체의 유동현상에 관하여 연구를 하였다. 뉴턴유체인 물의 점성계수 일때와 비뉴턴유체인 혈액의 Carreau model에서의 영전단율 점성계수(${\eta}_0$)와 무한전단율 점성계수(${\eta}_{\infty}$)일 때의 유동현상을 살펴보았다. 그 결과 점도가 증가할수록 재순환 영역에서 유체의 속도가 감소하였고 CF 및 CP값이 감소하는 구간의 수가 증가하여 벽면의 저전단응력으로 인해 생기는 재순환영역의 수가 증가하는 것으로 나타났다.

  • PDF

Study on Reflected Pressure in a Shock Tunnel According to the Size of a Nozzle Throat (충격관 터널의 노즐목 크기에 따른 반사압력특성 분석)

  • Lee, Jong Kook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.6
    • /
    • pp.479-487
    • /
    • 2015
  • In a reflected shock tunnel, stagnation conditions of a nozzle are determined by the flow behind a reflected shock. When calculating the flow behind the reflected shock, unlike a shock tube, the flow leakage through the nozzle is to be considered. The analytical studies were done to find out the characteristics of the stagnation conditions of the nozzle with various nozzle throat size. Experiments and numerical simulations were also carried out for further understanding of the flow leakage effects. It was found that the nozzle stagnation pressure was diminished by the increase of the size of the nozzle throat. It was also found that the steady pressure in the stagnation were maintained well at the area ratio of the driven tube to the nozzle throat is 4.5.

PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method (3차원 곡관에서의 굴절률 일치법을 이용한 맥동 유동의 PIV 측정)

  • Hong, Hyeon Ji;Ji, Ho Seong;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.511-517
    • /
    • 2016
  • Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent $10^{\circ}$ from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

차세대원자로의 주증기관 파단사고시 안전주입수 직접주입에 대한 유체혼합해석

  • 강형석;조봉현;배윤영
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.304-309
    • /
    • 1996
  • 차세대원자로(KNGR) 안전주입계통은 원자로용기 하향유로(RVDC)로 직접주입(DVI)되도록 설계되며 이는 4-트레인 안전주입계통의 설계에 있어 고유한 기본구조이다. DIV 채택으로 인해 가압열충격(PTS)과 관련된 인허가 상의 관심사론 조사하고 DVI 주입구 위치에 대한 RVDC에서의 유체거동과 온도분포를 상용전산코드인 FLOW3D를 이용하여 분석하였다. PTS관점에서 가장 최악의 경우인 외부 전원상실을 동반한 영출력 주증기관 파단사고를 해석대상으로 하였으며 사고후 570 ~ 600초 사이의 과도상태를 분석하였다. 본 연구의 결과로 주증기관 파단으로 야기되는 자연순환에 의한 열혼합은 충분히 이루어져 RVDC에서의 온도가 R $T_{PTS}$ 이상임을 확인했고 손상루프측 위의 DVI 주입구의 유동중 일부가 손상루프측 저온관 유동과 상호작용하여 건전루프측 저온관아래로 흐르며 이 영향으로 건전루프측 저온관 아래에서의 온도가 국부적으로 감소함을 확인하였다.다.

  • PDF

Numerical Study on Flow and Heat Transfer Enhancement during Flow Boiling in Parallel Microchannels (병렬 미세관 흐름비등의 유동특성 및 열전달 향상에 대한 수치적 연구)

  • Jeon, Jin-Ho;Lee, Woo-Rim;Suh, Young-Ho;Son, Gi-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.472-473
    • /
    • 2008
  • Flow boiling in parallel microchannels has received attention as an effective heat sink mechanism for power-densities encountered in microelectronic equipment. the bubble dynamics coupled with boiling heat transfer in microchannels is still not well understood due to the technological difficulties in obtaining detailed measurements of microscale two-phase flows. In this study, complete numerical simulation is performed to further clarify the dynamics of flow boiling in microchannels. The level set method for tracking the liquid-vapor interface is modified to include the effects of phase change and contact angle. The method is further extended to treat the no-slip and contact angle conditions on the immersed solid. Also, the reverse flow observed during flow boiling in parallel microchannels has been investigated. Based on the numerical results, the effects of channel shape and inlet area restriction on the bubble growth, reverse flow and heat transfer are quantified.

  • PDF

Effect of nonuniform perforation in the concentric resonator on the transmission loss and back pressure (동심관형 공명기 내부의 천공 요소의 불규칙한 배열이 전달손실 및 배압에 미치는 특성 연구)

  • ;Antoine Delaigue
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.515-519
    • /
    • 2002
  • 자동차 및 유체기계의 흡기계나 배기계에 사용되는 소음기의 음향성능은 전달손실로 기계성능은 배압으로 표현된다. 유체가 흐르는 관 사이의 임피던스 부정합을 이용하는 반사형 소음기의 경우, 내부 유로에 천공을 주어 음향감쇠를 시키거나 유동을 안정시키는 경우가 많다. 본 연구에서는 동심관형 공명기의 내부 관에 존재하는 천공의 분포 양상이 소음기의 전달손실과 배압에 미치는 영향을 실험을 통하여 고찰하였다. 내부관의 평균 천공율은 일정하지만 길이 방향을 따라서 천공율이 변하는 다섯가지의 공명기에 대한 실험을 수행하고, 성능에 미치는 영향을 살펴보았다. 전달손실은 천공요소의 임피던스 모델을 고려하여 예측한 결과와 비교하였고, 측정된 배압은 모의 해석 결과와 비교하였다. 분석 결과, 천공율이 점점 작아지는 분포나, 작았다가 커진후 다시 작아지는 형태의 분포를 가질 경우, 배압 측면에서 매우 유리하고, 음향 전달손실도 큰 차이가 없음을 밝혔다.

  • PDF

천마 연소관 브라켓 가공공정 개선

  • 김창식;최열경;양재일
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.27-33
    • /
    • 1993
  • 천마 연소관 및 Bracket는 고강도 특수강의 일종인 Maraging steel C-250 Grade로서 유동성형공정 (flow forming process: F/F) 및 용접공정을 거쳐 시효경화후의 경도(HRC 48-52)가 높아 절삭가공 및 Tapping에 어려움이 있다고 판단되어 브라켓 밀링가공(Tapping포함)을 시효경화공정 이전에 완성하는 것으로 공정 FLOW를 설정하였으나, 시효경화 시 유동성형공정 잔류응력 및 재질특성에 의한 수축, 변형 등으로 도면상 요구된 품질(형상 및 위치공차) 만족이 미흡하였을 뿐만 아니라 오히려 전체 공정 수만 증가하였음. 따라서 연소관 및 Bracket 완성가공을 시효경화 후에 실시하는 것으로 공정 개선 하고자 시험 작업한 결과, 선삭, 밀링작업등 다른 기계가공 공정의 문제점은 대부분 해결할 수 있었으나, Tapping공정만은 해결할 수 없어서 진정한 공정개선을 기할 수 없었음. 그러나, 제품의 품질 및 생산성을 고려 시효경화 후 Tapping 공정실시 필요성이 강력히 대두되어 Maraging steel 재질특성에 적합한 공구 및 작업조건을 검토, 설정 시험작업 함으로써 공정개선을 이룰 수 있었음.

  • PDF

Heat Transfer Characteristics of Cost Effective Plate Fin-tube Condenser for Household Refrigerator (가정용 냉장고의 응축기 비용저감을 위한 판형 핀-관 열교환기의 열전달 특성)

  • Son, Young-Woo;Lee, Jang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.323-327
    • /
    • 2008
  • 본 연구는 판형 핀-관 열교환기의 열전달 특성을 상용 CFD 코드인 SC/Tetra를 사용하여 해석한 내용에 관한 것이다. 해석조건은 입구속도 0.63 m/s, 튜브온도 $44.5^{\circ}C$이다. 해석 열교환기는 총6가지로 검토하였으며 각각의 온도분포와 유동패턴을 해석하고 판형 핀-관 열교환기의 열전달 특성을 비교 검토하였다.

  • PDF

Flow characteristics of supersonic twin-fluid atomizers (초음속 2유체 분무노즐의 유동 특성)

  • Park, Byeong-Gyu;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2267-2276
    • /
    • 1996
  • Twin-fluid atomization has been widely used in combustors and process industries because of its high performance and simple structure. Flow visualization and pressure measurements were conducted to investigate the effects of gas flow in twin-fluid atomization. Schlieren photographs showed that changes in atomizing gas pressure, altered the wave patterns, and the lengths of both recitrculating toroid (impinging stangnation point) nad supersonic flow region in the jet. A longer supersonic wave pattern like net-shape wqas observed as atomizing gas pressure increased. The disintegration phenomenon of liquid delivery tube. The variation of spray angles with gas pressures were obtained by visualization using laser sheet beam. Suction pressuresat the nozzle orifice exit and recirculating region are shown to be used to estimate the stable atomization condition of a twin-fluid atomizer.