• Title/Summary/Keyword: 관 삽입

Search Result 260, Processing Time 0.034 seconds

Design of a Partial Inter-tube Lancing System actuated by hydraulic power for type F model Steam Generator in Nuclear Power Plant (수압구동 전열관다발 부분 삽입형 증기발생기 세정장비 설계)

  • Kim, S.T.;Jeong, T.W.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1132-1135
    • /
    • 2008
  • The sludge grown up in steam generators of nuclear power plants shortens the life-cycle of steam generators and reduces the output of power plants. So KHNP(Korea Hydro and Nuclear Power), the only nuclear power utility in Korea, removes it periodically using a steam generator lancing system during the outage of plants for an overhaul. KEPRI(Korea Electric Power Research Institute) has developed lancing systems with high pressured water nozzle for steam generators of nuclear power plants since 2001. In this paper, the design of a partial inter-tube lancing system for model F type steam generators will be described. The system is actuated without a DC motor inner steam generators because the motors in a steam generator make a trouble from high intensity of radioactivity as a break down.

  • PDF

A study on the Development of Purge Burner for City Gas (도시가스용 퍼지 버너 개발에 관한 연구(II))

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.175-179
    • /
    • 2000
  • A combustion project was completed regarding the development of a high-flow-rate purge burner in cooperation with three city gas companies(Pusan, Taegu, Samchulli). The project, started in May 1991, aimed at purging the line-packed-gas safely and quickly before getting into gas pipe working or relocation. According to the results, the purging noise is less than 80dB due to silencer screen. multi-nozzle and outlet inserted tube employed. In addition, the developed burner shows an increased work efficiency of 40-50% more as compared to the performance of conventional purge equipments. The project result is regarded as the first high-flow-rate purge burner developed within Korea. contributing to shortening purge hours, safe field work and easiness of purge site selection.

  • PDF

Sample of Presentation Title of Surface Engineering (마이크로파 Plasma 탄소 섬유 처리 장치에서 입력 전력에 따른 온도 변화)

  • No, Ji-Hyeon;Hong, Gwang-Gi;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.162-162
    • /
    • 2011
  • 고강도 저가형 탄소 섬유 제작에 마이크로파 장비를 이용하는데 있어 공정 제어를 위한 온도 측정이 중요하다. 석영관 내부에 들어 있는 섬유의 표면 온도를 측정하기 어려우므로 직접 삽입한 K타입 열전대를 이용하여 입력 전력에 따른 섬유 다발 표면의 온도를 측정 하였다. 그 결과 안정화에 필요한 $300^{\circ}C$ 부근의 온도는 쉽게 얻을 수 있었으나 마이크로파가 방사되는 영역의 온도만 빠른 상승을 보여서 불균일도 해결을 위한 노력이 필요하다. 탄화 처리를 위한 고온 가열을 위해서 투입 전력을 648 W까지 증가시켰을 때 $727^{\circ}C$까지는 쉽게 상승하였으나 $2000^{\circ}C$ 이상을 획득하기 위해서는 고온 복사 손실을 줄 일 수 있는 전략이 필요하다.

  • PDF

X-band Compact Digital Phase Shifter Design (X 대역 소형 디지털 위상 천이기 설계)

  • 엄순영;전순익;육종관;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.907-915
    • /
    • 2002
  • In this paper, a compact digital phase shifter to be used an active phased array antenna system for satellite communications was proposed. The even and odd mode analysis for a given reflection-type phase shifter, which uses a folded hybrid coupler as a base element, was performed and the design parameters were derived. Also, to verify experimentally the electrical performances of the proposed structure, X-band 4-bit digital phase shifter was designed and fabricated using Teflon soft substrate $({\varepsilon}_r; =\;2.17)$. Its circuit size was less than 3.5 cm $\times$ 3.0 cm, and it exhibited at least 50 % size reduction as compared with the conventional unfolded configuration. The experimental results of the fabricated phase shifter showed that the average insertion loss and insertion loss variation were less than 3.5 dB, $\pm$ 0.6 dB within the operating band, 7.9 ~ 8.4 GHz, respectively. And, input and output return loss were more than 10 dB, respectively. Also, the phase response of the phase shifter showed 4-bit operation with $\pm$3$^{\circ}$ rms phase error.

Operative Treatment of Mitral Valve Regurgitation due to Papillary Muscle Rupture from Acute Myocardial Infarction Under ECMO -A case report- (급성심근경색 후 발생한 유두근 파열로 인한 승모판 판막 폐쇄부전의 체외막 산소화 장치하 승모판막 치환술 - 1예 보고 -)

  • Joo, Seok;Choo, Suk-Jung;Jung, Sung-Ho;Je, Hyoung-Gon
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.172-175
    • /
    • 2010
  • A 61-year-old man presented with chest pain and ST elevation, and he underwent coronary angiography under the impression of acute myocardial infarction. Coronary intervention under intra-aortic balloon pumping was necessary due to his hemodynamic instability from the acute total occlusion of a large obtuse marginal branch. In spite of successful intervention, the cardiogenic shock persisted, and so extracoporeal membranous oxygenation was performed to treat this. Afterwards, the cardiogenic shock still persisted, and the auscultatory and echocardiographic findings revealed severe acute mitral valve regurgitation. Emergency mitral valve replacement was then performed. The ECMO and IABP were removed on the $2^{nd}$ postoperative day. The patient was discharged on the $48^{th}$ postoperative day.

A Study on the Influence Factors for Ablation Rate of Graphite Nozzle Throat Insert (흑연 노즐목 삽입재의 삭마율에 미치는 영향 인자 연구)

  • Hahm, Heecheol;Kang, Yoongoo;Seo, Sangkyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.12-20
    • /
    • 2017
  • The ablation characteristics of graphite nozzle throat insert was analyzed for the use in solid rocket propulsion system. The propulsion system was composed of three types of conventional nozzles, such as De-Laval type, blast tube type, and submerged type. Various kinds of propellants were used in ten kinds of propulsion system that had different shapes with each other. Total forty eight tests were performed. From the results of the analysis, it was found that the ablation rate was increased for the higher average chamber pressure and the higher oxidizer mole fraction. A useful correlation for nozzle throat ablation rate was developed in terms of the chamber pressure, oxidizer mole fraction, and throat size. The calculated ablation rates from the correlation showed agreement within ${\pm}0.10mm/s$ with the experimentally determined values.

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF

Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow (정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성)

  • 이홍철;김철생;박복춘;박복춘
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • This experimental study is aimed at evaluating the hydrodynamic performance of newly designed self-expandable graft stents under steady flow condition. Two graft stents with different coating materials and a bare TiNi metallic stent for comparison test were used in the experiment. Pressure variation and velocity distribution at the upstream and downstream of the stents were measured at flow rates of 5, 10, and 15 l/min, respectively. Pressure loss due to insertion of the stent increased with increasing flow rate exponentially as expected. At a flow rate of 15 l/min, pressure loss of Polyure-thane(PU)-coated graft stent was 6 times higher than that of TiNi metallic stent, while the pressure loss of a porous Polytetrafluoroethylene(PTFE)-coated graft stent was comparable to a bare TiNi metallic stent. Velocity profiles of the porous PTFE-coated graft stent were similar to those of a bare TiNi metallic stent regardless of flow rate. Furthermore, the velocity profile of PU-coated graft stent revealed an asymmetrical and relatively low central velocity at a higher flow rate than 10 1/min, expecially, where the effects resulted in increases of wall shear stress and normal stress. The worse hydrodynamic behavior of PU-coated graft stent than the other two stents might be attributed to formation of folds due to poor flexibility of coated material when inserting the graft stent into the pipe with a more smaller size, which later gave rise non-symmetry of flow area, increase of surface roughness and jet flow via the crevice between the stent and cylinder wall.

Humidification of Air Using Water Injector and Cyclonic Separator (관 내 삽입 인젝터와 사이클론을 이용한 공기 가습)

  • Kim, Beom-Jun;Kim, Sung-Il;Byun, Su-Young;Kim, Min-Soo;Kim, Hyun-Yoo;Kwon, Hyuck-Ryul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.491-498
    • /
    • 2010
  • Humidification of PEM fuel cells is necessary for enhancing their performance and lifetime. In this study, a humidification system was designed and tested; the system includes an air-supply tube (inner diameter: 75 mm) through which a nozzle can be directly inserted and a cyclonic separator for the removal of water droplets. Three types of nozzles were employed to study the influence of injection pressure, air flow rate, and spray direction on the humidification performance. To evaluate the humidification performance, the concept of humidification efficiency was defined. In the absence of an external heat source, latent heat for evaporation will be supplied by the own enthalpies of water and air. Thus, the amount of water sprayed from the nozzle is the most critical factor affecting the humidification efficiency. Water droplets were efficiently removed by a cyclonic separator, but re-entrainment occurred at high air flow rates. The absolute humidity and humidification efficiency were $21.29\;kJ/kg_{da}$ and 86.57%, respectively, under the following conditions: nozzle type PJ24; spray direction angle $90^{\circ}$; injection pressure 1200 kPa; air flow rate 6000 Nlpm.

Fabrication of Ionization Chamber to Measure the Burnup of Spent Fuel (사용후핵연료 연소도 측정을 위한 이온 챔버 제작)

  • Park, Se-Hwan;Eom, Sung-Ho;Shin, Hee-Sung;Lim, Hye-In;Ha, Jang-Ho;Kim, Han-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.21-25
    • /
    • 2010
  • Burnup of spent fuel should be determined accurately for the safety control of spent fuel. Especially, it is necessary to measure the burnup profile along the nuclear fuel axis. In the present work, an ionization chamber was designed and fabricated to measure the gamma ray profile inside the guide tube of spent fuel. The ionization chamber was composed of three parts; induction part, gas-inlet part, and sensor part. The sensor part had two electrodes; cathode and anode. A guide electrode was considered in the ionization chamber design to make the ionization chamber to be inserted easily into the guide tube. Pure gas (argon and xenon) was inserted into the ionization chamber, and the leakage current and saturation curve were measured to determine the operation characteristics of the ionization chamber. The gamma ray radiation was also measured in relatively high dose environment. The gamma ray profile of the spent fuel will be measured with the ionization chamber.