The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters (PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화)

  • Shin, Gyoo-Seul;Dong, Kyeong-Rae
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • Purpose : There is difference between PET and PET/CT method on their transmission image for attenuation correction. The CT image is used for attenuation correction on PET/CT and the parameters of CT may be affected on PET image. We performed the phantom study to evaluate whether the change of CT parameters(kilovolts peak and milliampere) affect standardized uptake value(SUV) on PET image. Material and Method: The data spectrum lung phantom containing diluted [18F]fluorodeoxyglucose ([18F]FDG) solution(1.909 mCi for phantom 1, $913\;{\mu}Ci$ for phantom 2) was used. The CT images of phantom were acquired with varying parameters (80, 100, 120, 140 for kVp, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 for mA). The PET images were reconstructed with the each CT images and SUVs were compared. Result : The SUVs of phantom 1 reconstructed with each 80, 100, 120 and 140 kVp showed $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$ and $12.27{\pm}0.009$, respectively. The SUVs of phantom 2 revealed $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$ and $4.52{\pm}0.005$ with elevation of voltage. There was no statistically significant difference of SUVs between groups based on various kVp. Also SUVs of phantom 1 and 2 showed no significant change with elevation of milliampere in CT parameter. Conclusion : The parameters of CT did not significantly affect SUV on PET image in our study. Therefore we can apply various parameters of CT appropriated for clinical conditions without significant change of SUV on PET CT image.

  • PDF

Development of An Electronic Ballast for High pressure Sodium Lamp (고압나트륨램프용 전자식 안정기 개발)

  • 최현배;이진우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.21-22
    • /
    • 1998
  • 본 논문에서는 100[W] 고압나트륨램프용 전자식 안정기를 제작하여 전기적 특성을 측정하였다. 개발한 전자식 안정기는 입력전압 277[V], 입력전류 357[mA], 역률 98[%], 시동전압 1.1[kV], 관전압 91[V], 관전류 1.0[A]의 특성을 갖는 것으로 측정되었다.

  • PDF

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

A Study on Constant Current Boosted Squarewave Driving Electronic Ballasts for High Pressure Mercury Are Iamp (정전류 쵸핑을 이용한 구형파 구동형 고압 수은 방전등용 전자안정기 설계에 관한 연구)

  • 정화진;지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.1
    • /
    • pp.23-29
    • /
    • 1995
  • There are many articles about the HID lamps about it's characteristics and simulation methods for lamp design or ballast design. For the electronic ballasts of HID lamps, There are some problems caused by acoustic-resonance which destabilizes the arc of HID lamps. So, some studies suggest the methods to avoid it. For example, the methods suggested are high frequence driving over 100[kHz], and mixed frequence driving which alternates high frequence and low frequence, and squarewave driving etc. This study suggests the electronic ballast of HID lamps that solves the problems of acoustic-resonance, and can control the luminance by constant current boostes chopper of which frequence is 30[kHz] and by the squarewave driving of which frequence is 55.5[Hz.] As follows, we have the good electronic ballast for HID lamps which has the characteristics of a light weight, and a function of luminance control and a high quality luminosity and which saves electrical energy.

  • PDF

A Study on Measurement of Output Dose in X-ray Unit (X-선장치에서 출력선량 측정에 관한 연구)

  • Kim, Jong Eon;Lee, Sang Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.289-294
    • /
    • 2020
  • In order to control the quality of X-ray images and patient exposure, it is necessary to document the output dose(air absorption dose(mGy)) output from the X-ray unit from the measurement. The purpose of this study is to find an equation that can calculate the output dose from the measurement of the output dose and output factor(Of) of the X-ray Unit. The output dose and output factors of the X-beam irradiated from the X-ray unit were measured using an XR multi-detector. The output dose calculation formula was obtained by fitting the measured output dose divided by the tube current-exposure time product(mAs) and the set tube voltage with Allometric1. The final output dose calculation formula was obtained by multiplying this formula with the output factor. It is considered that the obtained final output dose calculation formula will be useful for all tube voltages, tube currents, exposure times, field sizes, and distances.

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

Evaluation of Area Dose Product and Image Density according to the Variable Tube Current (관전류 변화에 따른 면적선량과 영상 농도 평가)

  • Yun, YoungWoo;Je, Jaeyong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.645-650
    • /
    • 2018
  • This research aims at measuring images density of according to DAP(dose area product), and suggesting the need to quality control of exposure dose. When tube voltage was fixed as 80 kVp and tube current was set as 1, 25, 50, 80, and 100 mAs, with the increase of DAP from 25 mAs to 50 mAs, the dose also rose 1.88 times as much as before, and with the increase from 50 mAs to 100 mAs, it got 2.05 time higher than before. However, the images density obtained as film grew as much as 48% with the increase from 25 mAs to 50 mAs, and 29% with the increase from 50 mAs to 100 mAs. In addition, it has been found out that the higher the DR images density got from 25 mAs to 50 mAs, the bigger it became by 12%, and that it got bigger by 30% with the increase from 50 mAs to 100 mAs. In other words, the differences in the image density by the increase of the dose with the digital imaging equipment in a proper condition was proved to be less than in the film images. Based on the results of this research, medical institutions using a digital imaging equipment are expected to be able to reduce exposure dose of each region of interest than now through the quality control of radiation dose.

Dose Reduction of the Adolescent Female Breast during Scoliosis Radiography (청소년기 여성의 척추측만증 검사에서 유방입사선량 저감효과)

  • Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.373-379
    • /
    • 2018
  • The purpose of this study was to investigate quantitative data on the difference in breast entrance surface dose with changes in focus-film distance, patient posture (anteroposterior-posteroanterior), thoracic wall thickness, rib bone thickness, lung tissue thickness, tube voltage, and high-voltage rectification method in Whole Spine Scanography, which is necessary for the treatment of scoliosis patients. Given a tube voltage of 90 kVp, kerma of 0.1 mGy, focus-film distance of 260 cm, tube voltage ripple rate of 0, filter thickness of 3.5 mm, and thickness of patient's thoracic wall of 120 mm as an X-ray exposure condition, from the simulation results using the Simulation of X-ray Spectra program to confirm the reduction effect of breast entrance surface dose according to the patient's posture (AP and PA), there was a dose reduction effect in aluminum filter thickness of 2.6 times at 3.5 mm, 25.7 times the thoracic wall thickness at 120 mm, 1.43 times higher tube voltage, and 0 to 1.14 times the tube voltage ripple rate. The total dose reduction effect was about 109 times. In order to confirm the dose reduction effect of RANDO phantom posture (AP and PA), from the results of the measurements taken under the conditions that the focus-film distance was 260 cm, the tube voltage was 90 kVp, the tube current was 270 mA, the exposure time was 0.31 sec, and the tube voltage ripple rate of X-ray generators was 0, the entrance surface dose reduction effect of the breast in the PA position was found to be 20.56 times lower than that of the AP position.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF