• Title/Summary/Keyword: 관심도

Search Result 22,531, Processing Time 0.062 seconds

Quality of Life and Its Related Factors of Radiation Therapy Cancer Patients (방사선 치료를 받은 암환자의 삶의 질과 관련요인)

  • Shin, Ryung-Mi;Jung, Won-Seok;Oh, Byeong-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gyu;Lee, Sok-Goo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.21-29
    • /
    • 2011
  • Purpose: The purpose of this master's thesis is to utilize basic data in order to improve the quality of life of cancer patients who received radiation therapy after analysing related factors that influence patient's quality of life and obtaining information about physical, mental problems of patients. Materials and Methods: By using a structured questionnaire about various characteristics and forms of support, I carried out a survey targeting 107 patients that experienced radiation therapy at a university hospital in the Daejeon metropolitan area from July 15 to August 15, 2010 and analysed the factors influencing quality of life. Results: In case of pain due to disease, 65.15 and painless 81.87 showed a high grade quality of life. As body weight decreases, the quality of life become lower. When the grade of quality of life according to economic characteristics was compared, all items except treatment period showed a difference (P=0.000). When the score of social support, family support, medical support and self-esteem was low, the mark of quality of life showed respectively 61.71, 68.77, 71.31, and 69.39 on the basis of 128 points. When the score of support form was high, the mark of quality of life showed 90.47, 83.29, 90.40, and 90.36 (P<0.05). When analyzing the correlation between social support, family support, medical support and self-esteem and the degree of quality of life, social support was 0.768, family support 0.596, medical support 0.434, self-esteem 0.516. They indicated the correlation of meaningful quantity statistically (P<0.01). The factors that improved the quality of life were married state, having a job and painless status. As monthly income increases, the quality of life was also much improved (P<0.05). Among the factors related to quality of life, social support and medical support and higher self-esteem scores of the quality of life score increased 0.979 point, 0.508 points and 1.667 point, respectively. Conclusion: In conclusion, the quality of life of cancer patients that received radiation treatment is related to social support, medical support and self esteem. Self-esteem is an important factor that influenced quality of life, so if government offers works that doesn't affect patient's health, they are a useful method that maximize self-esteem and lessen their financial burden at the same time. Along with these policies, the developments of the attention of medical and the program for cancer patient's family are needed for the purpose of improving quality of life of cancer patients. Lastly, medical team, patients and family have to cooperate in harmony to overcome difficulties of cancer patients.

  • PDF

Relationship between Stress and Eating Habits of Adults in Ulsan (울산지역 성인 남녀의 스트레스와 식습관)

  • Kim, Hye-Kyung;Kim, Jin-Hee
    • Journal of Nutrition and Health
    • /
    • v.42 no.6
    • /
    • pp.536-546
    • /
    • 2009
  • This study was done to investigate the effect of stress on appetite and eating habits, and other health-related behaviors. The subjects of this study consisted of 188 males and 224 females in Ulsan area. The results were as follows: When stressed, 56% (n = 231) of the subjects experienced a change in appetite and of these, 32% (n = 132) experienced an increased appetite. Stress-induced eating may be one factor contributing to the development of obesity. There was a gender-specific response to stress in which women are more likely to use food to deal with stress, whereas men are more likely to use alcohol consumption or smoking. It was found that types of stressors were individual (52.9%), social (50.7%), family relations (34.5%), work demands (34.2%) and physical environment (32.3%). Stress-induced symptoms of the subjects were anxiety (38.3%), headache (36.7%) and neck or shoulder aches (36.2%), and females experienced those symptoms more than males. Those older than 50 years had a higher eating habit score and lower stress score compared with younger subjects. There were significant differences between sex, age, occupation, family type, BMI, exercise, sleeping hours and eating habits or stress level. This study may be helpful in advancing findings in this area to better provide health professionals with appropriate counseling tools to improve the health of all individuals.

Recognition and Attitude to Implement at ion of Service Area Assigned System of Public Health Programs among the Health Officer (공공보건사업의 지역담당제 실시에 관한 보건기관 근무 공무원의 인식과 태도)

  • Kim, Mi-Soon;Lee, Moo-Sik;Kim, Nam-Song
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.2
    • /
    • pp.15-41
    • /
    • 2001
  • Since medical clients and the community they live in are expected to be center of future public health and medical care system, new service programs must be developed with patients focused on in line with widening public access of information and social participation. Patients- focused service shall mean the area- oriented provision of public health service. In this study, health officers working at public health centers, public health sub- centers and medical offices in Jeonbuk- do area were taken for population in order to investigate their attitudes toward and knowledge about the service area assigning system under the public health programs. Findings from the survey to 260 health officers, divided by general category, are as follows : Government officers at public health organizations appeared to have high grade of understanding to the service area assigning system and also great appreciation for the necessity of it. Regarding the timing for the system to be introduced, they support the gradual implementation and, as for the type of service to be provided, they preferred home nursing and treatment of chronic diseases. Highly positive responses were centered on the health classes under the health promotion projects, and as far as health projects for the old are concerned, services for home nursing, for the disabled and for home- alone people are favored most. On the other hand, budgeting, manpower and reorganization are rated as prerequisite to establishment of the service area assigning system. From the viewpoint of system side, the improvement of working conditions is rendered as most urgent, while the information system for establishing the service area assigning system is conceived far from satisfactory. Proper assignment of specialists was noted as mostly important to establish the delivery system for medical service through the service area assigning system by team. As merits of the service area assigning system, it is pointed out that, through the system, health clients can better be managed and the nursing quality will be improved thank to the enhanced specialization. It is also perceived that the district health service is not well prepared to respond to the increased and diversified needs of community people and, furthermore, service programs of health centers have not been fully developed. The most serious problem standing in the way to expansion of health projects is, it is noted, uniformity (formality) of the project. Based on the results of the survey which suggest time has ripen to introduce the service area assigning system, following strategies are proposed to anchor down the system as soon as possible: First, we should introduce the system gradually, starting from the area selected, and in consideration of area specialities, refraining from the hitherto stereotyped way of providing health service. Second, we should seek to properly assign the specialists and improve the working conditions of the assigned officers by securing sufficient budget, since it is a most urgent step to lay foundation for the service area assigning system. Third, best service program should be developed to meet the satisfaction of community people by responding to their needs and solidifying the management of medical clients. Fourth, wide scope of study should further be conducted in order to help this system take roots in the central living of community residents since pilot project on the experimental base attended by specialists only can not win popularity among the masses.

  • PDF

Bone Density and Related Factors of Food and Nutrition Major and Non-Major University Students in Seoul Area (서울지역 식품영양전공.비전공대학생의 골밀도에 미치는 영향요인에 관한 연구)

  • 정남용;최순남
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.13 no.5
    • /
    • pp.391-407
    • /
    • 2003
  • This study was conducted to investigate the factors affecting the born density of food and nutrition major and non-major university students in Seoul area. Data for food habits, dietary and health-related behavior were obtained by self administered questionnaires. BQI(bone quality index) of the subjects were measured by Quantitative Ultrasound (QUS). The results are summarized as follows: The average height, weight, BMI and osteopenia percentage of the major and non-major male and female student were l74.49cm, 67.05kg, 21.96 and 22.0%; l74.34cm, 65.98kg, 21.69 and 11.8%; l60.76cm, 54.48kg, 21.07 and 40.0%; l61.30cm, 54.22kg, 20.84 and 40.2%, respectively. The BQI of the major and non-major subjects were 108.07 and 110.47 in male student group, and 89.13, 88.18 in female student group, respectively. The T-score and Z-score of bone density of the subjects were not significantly different. Weight and BMI were positively related with BQI in male and female group but the relationship with BMI tended to be stronger in non-major female group than other groups. BQI was positively affected by exercise time, favorite food, and intake of seafood and tea in major and non-major male student group. One-side eating habit and intake of instant foods were negatively related with BQI in both male groups. In major and non-major female student group, exercise time, meal regularity, favorite food, amount of meal, intake of tofu were related with BQI positively and intake of tea and/or meats negatively. The result of this study revealed that desirable food habits, dietary behavior and health-related lifestyle may have a beneficial effect on bone density. They need practically and systematically organized nutrition education on optimum body weight, good eating habits, weight bearing exercise and intakes of good quality nutrient for higher bone density level.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

INDIVIDUALIZED RECONSTRUCTION OF THE LOWER OCCLUSAL PLANE ACCORDING TO SKELETAL PATTERN (안면 골격 형태에 따른 하악 교합평면의 재구성)

  • Hyun, Seong-Wook
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.465-485
    • /
    • 1995
  • The purpose of this study is to locate the proper position of the lower occlusal plane according to individual skeletal pattern. Cephalometric films of 234 subjects of the control group, 358 of the pretreatment group and 358 of the treated group were analyzed to study proper relationships between vertical dimension ratio(VDR) and lower occlusomandibular plane angle(LOM). The control group was divided into two subgroups by the age. The first subgroup consisted of 113 subjects of the age 14 years and under and with the mean age of 10.82 years. The other subgroup consisted of 113 subjects of the age 18 years and above with the mean age of 23.76 years. The pretreatment group was divided into three subgroups by the age. The first subgroup consisted of 274 subjects of the age 14 years and under with the mean age of 11.36 years. The second subgroup consisted of 54 subjects of the age 14 through 18 years with the mean age of 15.4 years. The last subgroup consisted of 30 subjects of the age 18 years and above with the mean age of 21.35 years. The treated group was also divided into three subgroups by the age. The first subgroup consisted of 145 subjects of the age 14 years and under with the mean age of 12.91 years. The second subgroup consisted of 166 subjects of the age 14 through 18 years with the mean age of 15.64 years. The last subgroup consisted of 47 subjects of the age 18 years and above with the mean age of 21.61 years. Cephalometric films of the sample were traced. Measurements were made to a hundredth using a program specifically prepared for this study, and the results were entered into a 486DX PC. Means and Standard deviations of all the veriables were calculated for each group. Correlation coefficients between pertinent variables were calculated. Significance tests on those coefficients, one-way ANOVA and t-tests between variables or groups were performed. On the basis of the results studied above, certain subjects were selected from the control and the treated groups to locate the proper position of the occlusal plane, and designated as the optimal occluaion group. The subjects of this optimal occlusion group had 1-3 mm overbite, 1-3 mm of overjet and less than 1.75 mm of curve of Spee. A total subjects of 187 in this group consisted 104 treated subjects and 83 control group. Regression analysis was carried out between VDR and LOM, and regression equations were tabulated for this optimal occlusion group. The results were as follows : 1. Highly significant correlations were observed between various variables useful for identifying vertical component of skeletal frame, but any one particular variable did not accurately indicate the magnitude of anterior vertical overbite. 2. Of the variables useful identifying vertical component of skeletal frame, The VDR showed the highest correlation to the LOM. 3. Of the total sample, 80 percent had overbite within the normal range, irrespective of VDR. 4. The optimal occlusion group was divided into 9 subgroups by the age and the anteroposterior skeletal pattern, and correlation coefficient and determination coefficient between VDR and LOM of each group were calculated. Correlation coefficients and determination coefficients were found to be significantly high in all groups. 5. Regression equation was induced for each of the optimal occlusion group to find proper LOM according to the VDR. 6. It was found that the mean value of the cant of occlusal plane itself is not enough for a diagnosis and a treatment plan. Rather, It is very important to locate the proper occlusal plane for an Individual skeletal pattern.

  • PDF

Customer Behavior Prediction of Binary Classification Model Using Unstructured Information and Convolution Neural Network: The Case of Online Storefront (비정형 정보와 CNN 기법을 활용한 이진 분류 모델의 고객 행태 예측: 전자상거래 사례를 중심으로)

  • Kim, Seungsoo;Kim, Jongwoo
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.2
    • /
    • pp.221-241
    • /
    • 2018
  • Deep learning is getting attention recently. The deep learning technique which had been applied in competitions of the International Conference on Image Recognition Technology(ILSVR) and AlphaGo is Convolution Neural Network(CNN). CNN is characterized in that the input image is divided into small sections to recognize the partial features and combine them to recognize as a whole. Deep learning technologies are expected to bring a lot of changes in our lives, but until now, its applications have been limited to image recognition and natural language processing. The use of deep learning techniques for business problems is still an early research stage. If their performance is proved, they can be applied to traditional business problems such as future marketing response prediction, fraud transaction detection, bankruptcy prediction, and so on. So, it is a very meaningful experiment to diagnose the possibility of solving business problems using deep learning technologies based on the case of online shopping companies which have big data, are relatively easy to identify customer behavior and has high utilization values. Especially, in online shopping companies, the competition environment is rapidly changing and becoming more intense. Therefore, analysis of customer behavior for maximizing profit is becoming more and more important for online shopping companies. In this study, we propose 'CNN model of Heterogeneous Information Integration' using CNN as a way to improve the predictive power of customer behavior in online shopping enterprises. In order to propose a model that optimizes the performance, which is a model that learns from the convolution neural network of the multi-layer perceptron structure by combining structured and unstructured information, this model uses 'heterogeneous information integration', 'unstructured information vector conversion', 'multi-layer perceptron design', and evaluate the performance of each architecture, and confirm the proposed model based on the results. In addition, the target variables for predicting customer behavior are defined as six binary classification problems: re-purchaser, churn, frequent shopper, frequent refund shopper, high amount shopper, high discount shopper. In order to verify the usefulness of the proposed model, we conducted experiments using actual data of domestic specific online shopping company. This experiment uses actual transactions, customers, and VOC data of specific online shopping company in Korea. Data extraction criteria are defined for 47,947 customers who registered at least one VOC in January 2011 (1 month). The customer profiles of these customers, as well as a total of 19 months of trading data from September 2010 to March 2012, and VOCs posted for a month are used. The experiment of this study is divided into two stages. In the first step, we evaluate three architectures that affect the performance of the proposed model and select optimal parameters. We evaluate the performance with the proposed model. Experimental results show that the proposed model, which combines both structured and unstructured information, is superior compared to NBC(Naïve Bayes classification), SVM(Support vector machine), and ANN(Artificial neural network). Therefore, it is significant that the use of unstructured information contributes to predict customer behavior, and that CNN can be applied to solve business problems as well as image recognition and natural language processing problems. It can be confirmed through experiments that CNN is more effective in understanding and interpreting the meaning of context in text VOC data. And it is significant that the empirical research based on the actual data of the e-commerce company can extract very meaningful information from the VOC data written in the text format directly by the customer in the prediction of the customer behavior. Finally, through various experiments, it is possible to say that the proposed model provides useful information for the future research related to the parameter selection and its performance.

Effects of Pranlukast on Ovalbumin Induced Early-Phase Bronchoconstriction in Guinea Pigs (기니픽에서 Ovalbumin으로 유발된 즉시형 기관지 수축반응에 대한 Pranlukast의 효과)

  • Lee, Sin-Hyung;Shim, Jae-Jeong;Kim, Kyung-Kyu;Jeong, Hye-Cheol;Kwon, Young-Hwan;Kim, Je-Hyeong;Lee, Sung-Yong;Lee, So-Ra;Lee, Sang-Youb;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.697-708
    • /
    • 1999
  • Background : Leukotriene (LT) $C_4$, $D_4$, and $E_4$, the main components of slow-reacting substance of anaphylaxis (SRS-A), have been suggested to play an important role in bronchial asthma such as antigen-induced bronchoconstriction, airway hyperreactivity, and pulmonary eosinophil accumulation. The purpose of this study was to evaluate the effects of treatment with the cysteinyl-LTs (cys-LTs) antagonist, pranlukast on allergen-induced guinea pig asthma model. Methods : Guinea pigs of treatment and placebo groups were sensitized by subcutaneous injection of ovalbumin(OVA) and challenged by inhalation of aerosolized OVA (1% weight/volume OVA). Normal control group did not sensitize with OVA. Oral ingestion of pranlukast and normal saline to the treatment and placebo groups was performed. In the treatment and placebo groups, airway resistance was measured before and after oral ingestion. Serum $LTC_4$ and eosinophilic infiltration of the bronchiolar and peribronchiolar tissues were measured after ingestion in the treatment and placebo groups. Results : Allergen-induced airway constriction developed in 20 (8 in treatment group, 12 in placebo group) among 35 guinea pigs. Airway resistance was significantly decreased at 3 and 6 minutes after OVA challenge in the pranlukast treatment group. In the placebo group, there was no difference of airway resistance between before and after saline ingestion. Serum $LTC_4$ levels showed 348.4 pg/ml in the treatment group, 373.9 pg/ml in the placebo group, and 364.4 pg/ml in the control group. There were no statistically significant difference between treatment and placebo group (p=0.232), and treatment and control group (p=0.501). Eosinophilic infiltrations in the peribronchiolar region per one-microscopic field ($\times$400 high power fields) demonstrated 7.06 in the treatment group, 19.2 in the placebo group, and 4.50 in the control group. There was significant decrement of eosinophilic infiltration in the treatment group which was compared with placebo group (p=0.001). Conclusion : These results demonstrate that pranlukast, a cys-LTs receptor antagonist, can attenuate allergen induced early-phase bronchoconstriction and eosinophilic infiltration in the bronchiolar tissues.

  • PDF

Antitumor and Antimetastatic Effects of Toxoplasma Gondii in Mice with Lewis Lung Carcinoma (Lewis 폐암 마우스 모델에서 톡소포자충에 의한 항암 및 항전이 효과)

  • Kim, Ju-Ock;Jung, Sung-Soo;Park, Hee-Sun;Kim, Myoung-Hoon;Kim, Sun-Young;Lee, Young-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.317-329
    • /
    • 2002
  • Background : Immunotherapy is another treatment modality for various cancers. There is little information on the antitumor effects of immunotherapy on implanted lung cancer mouse models. Toxoplasma gondii is able to potently induce a nonspecific stimulation of the host immune system. Therefore, this study evaluated the antitumor and antimetastatic effect of nonspecific immune stimulation by T. gondii in a Lewis lung cancer mouse model. Methods : Female C57BL/6 mice were injected with either Lewis lung cancer cells ($1{\times}10^6$ per mouse) or 5 cysts from the T. gondii Me49 strain with various schedules. The number of survival days, the tumor size of the implanted muscle and the histopathological findings of each group were noted. In addition to these mice, the Toxoplasma antigen($50{\mu}g$ per mouse) or a lymphokine (0.5 ml per mouse) was added to boost the immunotherapy. Results : No mouse in the Toxoplasma-infected group had died, whereas the mice receiving only the cancer cells (cancer control) survived for $29.1{\pm}4.4$ days. Cancer cells were revealed from 1 week after cancer cell inceulation in the muscle and from 3 weeks in the lung of the cancer control, whereas cancer cells were found in both the preinfection control and coinfection control groups from 2 weeks and 4 weeks in the lung respectively. The in the number of survival days were $32.4{\pm}3.3$ in the mice receiving T. gondii 2 weeks prior to the cancer cells inoculation (preinfection control), $30.9{\pm}5.1$ in mice received both simultaneously (coinfection control), and $34.9{\pm}2.9$ in mice received T. gondii 2 weeks after cancer cells implantation (postinfection control). These 3 infection groups had significantly longer survival days and suppressed tumor growth than those of the cancer control. In addition to these mice, and injection with the Toxoplasma antigen alone or in combination with lymphokine resulted in a significant increase in the number of survival days. Conclusion : These findings suggest that an injection with T. gondii can induce the antitumor and antimetastatic effects in Lewis lung cancer mouse models. Moreover, these effects were increased with an injection of the Toxoplasma antigen alone or in combination with lymphokine. However, this therapy can not prevent the development of cancer.