• Title/Summary/Keyword: 관수로

Search Result 155, Processing Time 0.034 seconds

Analysis of Operating and Maintenance Parameters for Agricultural Pipeline System Using EPANET (EPANET을 이용한 농업용 관수로 시스템의 운영 및 유지관리 인자 분석)

  • Kim, Nam Do;Kim, Sun Joo;Kwon, Hyung Joong;Kim, Phil Shik;Park, Hyun Jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.4
    • /
    • pp.17-26
    • /
    • 2017
  • In this study, EPANET model which is using on the pipe network analysis was applied to Haenam irrigation district has provided irrigation water by pipeline system about 1,125ha and then have built pipe network to study area and supply performance evaluation of existing structure was analyzed by SPA (Single Period Analysis) in EPANET. As model results of simulation average ratio of maximum supply quantity/irrigation water requirements(base demand) was analyzed by 2.63. It means also that was analyzed as being capable of ensuring the water supply capacity. It was provided the necessary information for the maintenance facility through analyzed hydraulic behaviors in the pipeline inside such as flow velocities, pressures and hydraulic grade lines. It was satisfied with the allowable design criteria that was compared analyzed results with presented allowable design standards at agricultural production infra improvement project planning and design (Pipeline design standard). In order to analyze efficiency promotions of irrigation water, using Extended Period Simulation it was compared supply quantity with irrigation water requirements while pumps set operating pattern in 24 hours, then efficiency promotions of irrigation water was determined through analyzed oversupply water quantity and occurrence time by branch lines. According to results for oversupply quantity in Haenam district by time and end of branch lines efficiency promotions of irrigation water was suggested from 0.33 % to 37.59 %. To draw reasonable operating rules for water use and through this research, it is expected to be helpful for efficient water use and operational management of agricultural pipeline system to the current agricultural irrigation.

Modelling Development and Environmental Analysis of Oriental Melon Greenhouse in SUNGJU(1) -Characteristics on distribution of air temperature for cultivating oriental melon in tunnel type greenhouse in Sungiu- (성주지역 참외전용 온실의 모델개발 및 환경분석(1) -성주 시설 참외단지 단동하우스의 온도 분포 특성-)

  • 송재관;박규식;구건효
    • Journal of Bio-Environment Control
    • /
    • v.7 no.4
    • /
    • pp.311-323
    • /
    • 1998
  • This study was conducted to analyze the temperature characteristics under tunnel type greenhouse to cultivate watermelon in Sungju region. Air temperature of tunnel type greenhouse was descending rapidly after sunset, and the time required the air temperature inside greenhouse nearly reached the outside air temperature was about 2.5 hours. The maximum air temperature in tunnel type greenhouse, in case of high air temperature day, was exceeding 4$0^{\circ}C$ during day time. Air temperature inside greenhouse during night time could sustain about 2~3$^{\circ}C$ higher than the outside air temperature. But it was necessary to supply supplemental heat when the air temperature was below optimum growth temperature. Soil temperature in the depth of 20cm under soil surface could maintain higher than 2$0^{\circ}C$ and the variation range in a day was 3~5$^{\circ}C$, and the soil temperature descending due to irrigation was about 5~6$^{\circ}C$.

  • PDF

A Study on Greenhouse Farmers' Willingness to Pay of Agricultural Water Supply through Pipeline (관수로 농업용수 공급에 대한 시설재배 농가의 비용 지불의사 연구)

  • Lim, Cheong-Ryong;Park, Seong-gyeong;Chung, Won-ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.2
    • /
    • pp.109-114
    • /
    • 2018
  • In this study, we estimate the greenhouse farmers' willingness to pay of agricultural water supply through pipeline. First, in the questionnaire design, orthogonal design and block design were used to enhance the ease of survey. Second, the theoretical model was constructed through the setting of the probability utility function, and the parameters were estimated by using the conditional logit model. Third, all of the estimation coefficients were statistically significant at the 1% significance level. The results of analysis are summarized as follows. First, the probability of selection is increased when maintenance is carried out by Korea Rural Community Corporation or local government. Second, the probability of selection is increased when agricultural water supply through pipeline is higher than the current level. Third, if the Korea Rural Community Corporation carries out maintenance management, the marginal willingness to pay is 44 won per ton. And if the local government carries out maintenance management, the marginal willingness to pay is 25 won per ton. Fourth, according to the quality level of agricultural water supply, the marginal willingness to pay is 101 won, 114 won and 120 won per ton, respectively. This study can be used as a basic data on the cost setting for agricultural water supply through pipeline.

Optimizing Planting Distance and Labor-Saving Efficiency for Head Lettuce Using a Transplanter for Summer Season Cultivation in the Alpine Area (고랭지 결구상추의 기계정식시 적정 재식거리 및 노력절감효과)

  • Jang, Suk-Woo;Kim, Won-Bae;Kim, Jin-Young
    • Horticultural Science & Technology
    • /
    • v.18 no.6
    • /
    • pp.787-791
    • /
    • 2000
  • Lettuce seedlings used in this investigation of planting distance and labor-saving efficiency were first grown in 100-hole paper trays for 30 days. Seedling height for transplanting ranged from 3 cm to 6 cm and plants had 3 to 5 leaves. The beds prepared for transplanting were of the arched type and were 35-40 cm in width, 15-20 cm in bed height, and between-bed furrow width was 20 30 cm. Typical seedling planting depth with the transplanter was 4-5 cm, although depth was quite variable because of the irregularities of the ground. Total transplanting time with the transplanter varied from 2.6 to 2.7 hours per 10a, while it took 38.1 hours per 10a with conventional planting. It was critical that the condition of both the seedlings and the bed be adjusted to the transplanter before planting. Considering yield and inter-plant distance, optimal transplanter performance resulted with $60{\times}20cm$ or $60{\times}25cm$spacing, and the labor-saving efficiency using the transplanter was improved by over 93% of that of conventional planting by hand.

  • PDF

Application of Levenberg Marquardt Method for Calibration of Unsteady Friction Model for a Pipeline System (관수로 부정류 마찰항 보정을 위한 Levenberg Marquardt 방법의 적용연구)

  • Park, Jo Eun;Kim, Sang Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.4
    • /
    • pp.389-400
    • /
    • 2013
  • In this study, a conventional pipeline unsteady friction model has been integrated into Levenberg Marquardt method to calibrate friction coefficient in a pipeline system. The method of characteristics has been employed as the modeling platform for the frequency dependant model of unsteady friction. In order to obtain Hessian and Jacobian matrix for optimization, the direct differentiation of pressure to friction factor was calculated and sensitivities to friction for heads and discharges were formulated for implementation to the integration constant in the characteristic method. Using a hypothetical simple pipeline system, time series of pressure, introduced by a sudden valve closure, were obtained for various Reynolds numbers. Convergency in fiction factors were evaluated both in steady and unsteady friction models. The comparison of calibration performance between the proposed method and genetic algorithm indicates that faster and stabler behaviour of Levenberg Marquardt method than those of evolutionary calibration.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

An application of Smoothed Particle Hydrodynamics on intake system analysis in a dam (입자법을 이용한 댐 취수 운영의 3차원 해석 적용)

  • Kim, Sunghoon;Cho, Kwangjoon;Park, Chungik;Moon, Sukju;Kim, Jongchan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.92-92
    • /
    • 2019
  • 최근 기존의 격자방식의 해석 방법을 벗어나 해석 영역에 대한 분할을 별도로 고려치 않는 수치기법의 실무적 적용사례가 증가 하고 있으며, 이러한 방식중 SPH(Smoothed Particle Hydrodynamics) 방식이 근자에 수자원 분야에서도 도입되어 관수로 및 개수로 해석 또는 복합해석 등에 활용된 바 있다. 최초 도입된 무격자방식의 모형들은 주로 복잡한 형상을 지니는 유체기계 등에 활용성이 높았던 바, 큰 규모의 해석 도메인을 가지는 수자원 분야에서의 SPH의 실무적용 평가와 효율성의 확보를 위해서, 본 연구는 국내 댐을 시범 대상으로 하여 SPH 수치해석 툴을 적용하고자 하였다. 분석 대상댐은 국내 P댐으로서 관리수위의 변동은 크지 않으나, 댐 직상류의 만곡이 심하고 다수의 대규모 취수구를 가진 곳으로 상시 발전방류 및 수시 댐 수문방류에 의해 유체의 흐름이 2,3차원의 복잡성을 띄고있기 때문에, 3차원 전산유체역학 Tool의 적용이 적절한 것으로 판단하였다. 해석을 위해 하류경계조건을 댐축과 문비로 설정하였고 상류 1km까지를 해석의 도메인으로 설정하였다. 소요시간을 줄이기 위해 여러 번의 모의를 거쳐 입자의 평균 입경은 0.6m로 제안하고 시격은 1초 미만(평균 0.5초)로 설정하였다. 수문 및 발전방류는 해당댐의 1~2년 빈도 수준에 해당하는 $5,000m^3/s$ 이하의 유량을 기준으로 하여 모의를 수행하였다. 모의의 안정성을 확보한 이후에는 해당 댐지역의 하류영향을 고려한 문비제어를 반영한 다양한 방식의 수문운영 및 취수지점의 순간 수위 영향을 검토하였다. 그 결과로 본 모의에서는 특정한 수문의 운영 조건에서는 댐수위 계측지점과 인근 취수지점 간에도 0.2m 수준의 순간 수위차가 발생할 수 있음을 보였으며, 이는 경우에 따라 취수시설의 일시적 장애요소로 발생할 수 있음을 의미한다. 따라서, 현재의 취수구조물과 문비운영 특성에 따라 발생가능한 취수장애를 줄일 수 있는 운영조건의 탐색을 위해서 수치모의를 추가로 하였으며, 이 때 댐축 상류의 유속분포에 대한 추가 검토도 수행하였다. 다만, 댐에서 방류시 하류조건에 대한 검토는 추후 보강되어야 할 것으로 판단된다.

  • PDF

Characteristics of pressure fluctuation by plunge pool depth of intake facility in deep rainwater storage and drainage system (대심도 빗물저류배수터널 유입시설 감세지 깊이에 따른 압력변화 특성 연구)

  • Jun Oh Oh;Sang Mi Jun;Jea Hyeon Park;Yong Jang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.108-108
    • /
    • 2023
  • 기후변화 및 도시화로 인해 도시 내에서 증가하는 홍수로 인명 및 재산피해가 꾸준히 발생하고 있다. 특히 2022년 8월 8일 서울특별시 및 경기도 지역에 내린 폭우로 인해 8명 이상의 인명피해와 1300억원 이상의 재산피해가 발생하였다. 이러한 도시홍수를 근본적으로 방어하기 위하여 미국, 일본 등의 국가에서는 대심도 빗물저류배수터널을 활용하고 있다. 국내에서도 2011년 서울특별시 강서구 및 양천구에 발생하는 홍수를 방어하기 위하여 국내 최초 대심도 빗물저류배수터널인 '신월 빗물저류배수시설'을 건설하여 현재 운영 중에 있다. 대심도 빗물저류배수터널은 초기 개수로 흐름에서 만관 후 관수로 흐름으로 전이되는 구조물로 계획과 운영이 매우 어려운 시설이다. 이에 미국, 일본, 중국, 이탈리아 등 국가에서 대심도 빗물저류배수터널과 관련한 연구가 활발히 진행되고 있다. 본 연구에서는 대심도 빗물저류배수터널의 유입시설 중 감세부에 해당하는 수직갱과 감세지의 깊이에 따른 감세지 바닥 압력변화를 알아보기 위하여 수리실험을 수행하였다. 그 결과 감세지 깊이가 깊어질수록 바닥면의 압력이 증가하는 것으로 분석되었으며 바닥면의 압력이 감세지 깊이만큼의 정수압을 포함하는 경우 정수압 대비 최대 2.0배, 정수압을 포함하지 않는 경우 정수압 대비 최대 1.0배 인 것으로 분석되었다. 수직갱 깊이에 대한 실험 결과는 수직갱 깊이가 짧아질수록 압력이 감소하는 경향을 보이는 것으로 분석되었는데 이는 회전수 및 회전력과 관련 있는 것으로 판단된다. 향후 수직갱 직경, 수직갱 깊이에 대한 추가 연구가 필요한 것판단되며 이를 통하여 수직갱 깊이-감세지 깊이에 대한 정량적인 연구와 분석을 통해 경제적이고 안정적인 대심도 빗물저류배수터널 감세지 설계가이드라인을 제시하고자 한다.

  • PDF

Evaluation of Effective Wall Roughness for 3D Computational Analysis of Open Channel Flow (개수로 흐름의 3차원 전산해석을 위한 유효 벽면거칠기 산정)

  • Choi, Junwoo;Baek, Un Il;Lee, Sang Mok;Yoon, Sung Bum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.627-634
    • /
    • 2008
  • In a numerical simulation of open channel turbulent flows using RANS (Reynolds averaged Navier-Stokes) equations model equipped with VOF (Volume of Fluid) scheme, the determination of wall roughness for wall function was studied. The roughness constant, based on the law-of-the-wall for flow on rough walls, obtained by experimental works for pipe flows is employed in general wall functions. However, this constant of wall function is the function of Froude number in open channel flows. Thus, the wall roughness should be determined by taking into account the effect of Froude number. In addition, the wall roughness should be corresponding to Manning's roughness coefficient widely used for open channels. In this study, the relation between wall roughness height as an input condition and Manning's roughness coefficient was investigated, and an equation for effective wall roughness height considering the characteristics of numerical models was proposed as a function of Manning's roughness coefficient.

Analysis of Non-Darcy Flour in Tide Embankment (호안제체에서 Non-Darcy 흐름해석)

  • Choi, Hung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • The simulation results using i- V relationship of non-Darcy flow through tide embankment by Li et al.(1998) agree well to the observed data. The use of i- V relationship is applicable to the engineering practice and the correct input of porosity is necessary. The non-Darcy flow based on the pipe flow and Taylor's definition for mean hydraulics radius in rockfill material is applicable to the block and caisson materials. The correct calculation of flow through tide embankment enables the accurate calculation of velocity at final closing gap and the prediction of inner water level after tide embankment construction as well.