• Title/Summary/Keyword: 공초점 주사현미경

Search Result 63, Processing Time 0.026 seconds

EFFECT OF ETCHING TIME ON ENAMEL SURFACE ROUGHNESS: CONFOCAL LASER SCANNING MICROSCOPIC STUDY (공초점 레이저주사현미경을 이용한 산부식 시간에 따른 법랑질 표면 양상에 관한 연구)

  • Kam, Dong-Hoon;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2003
  • In order to evaluate the sufficient etching time for successful bonding and also minimizing unnecessary mineral loss, the enamel surface roughness analysis was performed using confocal laser scanning microscopy. Sixty extracted sound human molar teeth were imbedded in the center of acrylic cylinder using self-curing clear resin exposing buccal surface, and then polished with series of SiC paper(220, 500, 800, 1000, 2000, 4000 grit). Each specimen was randomly assigned to six groups(N=10). 37% phosphoric acid was applied to the polished tooth surface for 10, 20, 30, 40, 50, 60 seconds respectively and washed with copious water. After the surface roughness analysis, five roughness parameters(Sa, Sq, Sz, Sdr, Ra) were statistically analysed by ANOVA and Duncan post hoc test. We found that the all five parameters had higher roughness value in 30 seconds etching time, especially parameter Sz showed the lowest value in 10 seconds etching time and the highest value in 30 seconds etching time compared with the other etching times(p<0.05).

  • PDF

Optoelectrical Characteristics of Electrospun PVP Nanofibers Incorporated with ZnS:Mn Nanoparticles (전기방사법으로 제작된 ZnS:Mn/PVP 하이브리드 나노사의 발광특성)

  • Kim, Kwang-Eun;Cho, Kyoung-Ah;Kwak, Ki-Yeol;Yoon, Chang-Joon;Kim, Sang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1599_1600
    • /
    • 2009
  • ZnS:Mn 나노입자가 포함된 PVP 고분자 하이브리드 나노사를 전기방사법으로 제작하였다. 하이브리드 나노사의 표면 특성은 주사 전자 현미경으로 관측하였으며, 형광분광광도계와 공초점 주사현미경 (CLSM)을 이용하여 하이브리드 나노사의 발광특성을 조사하였다. 순수한 PVP 나노사와 하이브리드 나노사의 photoluminescence (PL) 스펙트럼 비교를 통하여, 586 nm에서 관찰된 PL 피크는 ZnS:Mn 나노입자에서 기인되었음을 알 수 있었으며, CLSM을 이용하여 ZnS:Mn 나노입자의 발광을 이미지화 하였다.

  • PDF

Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope (공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구)

  • Lim, Soo-Hee;Kim, Wi-Han;Lee, Ho;Lee, Choon-Young;Park, Cheol-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

An experimental study of cutting efficiency of air-driven diamond burs on human tooth (수종 air-turbine 다이아몬드 버의 절삭 효과에 관한 실험적 연구)

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the cutting efficiency of coarse grit diamond burs with air-turbine handpiece on natural tooth. Materials and methods: Four groups of coarse grit diamond bur were selected: Komet (A), Shofu (B), Premier (C), and Mani (D). The extracted maxillary central incisors were used, and ten cuts were made on each specimen, using the rotary diamond burs. The surface of each bur was measured at the upper, middle, and bottom of the bur with confocal laser scanning microscope and imaged with SEM. The data were analyzed with one-way ANOVA and t-test at the significance level of 0.05. Results: The surface roughness was measured. At the A diamond bur, the Sa values were $52.93\;{\mu}m$, $48.32\;{\mu}m$, $46.79\;{\mu}m$, $45.06\;{\mu}m$, and $43.43\;{\mu}m$ for control, test 1, 2, 3, and 4 respectively. The Sa values were $50.68\;{\mu}m$, $45.62\;{\mu}m$, $44.41\;{\mu}m$, $44.10\;{\mu}m$, and $42.46\;{\mu}m$ for B diamond bur, $58.02\;{\mu}m$, $55.53\;{\mu}m$, $52.22\;{\mu}m$, $48.26\;{\mu}m$, and $45.36\;{\mu}m$ for C diamond bur, and $50.11\;{\mu}m$, $46.73\;{\mu}m$, $45.46\;{\mu}m$, $42.58\;{\mu}m$, and $41.80\;{\mu}m$ for D diamond bur. Surface roughness after each bur use showed significant changes, but no significant difference was found in surface roughness change between bur systems. Conclusions: Surface roughness in the same bur system showed significant differences after each tooth preparation. However no statistically significant differences were found in surface roughness between bur systems. The SEM images between control and test 4 showed the abraded particles.

The remineralization effect of topical fluoride agents using confocal laser scanning microscope on artificial enamel caries aspects of convergence observation (공초점 레이저 주사 현미경을 이용한 우치 인공우식법랑질에서 불소도포 전·후의 재광화 효과에 대한 융합적 관찰)

  • Lee, Min-Sun;Kim, Hyo-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.6
    • /
    • pp.139-145
    • /
    • 2017
  • The aim of this study was to measure the remineralization effect of APF gel and fluride varnish on artificial enamel caries using CLSM in vitro. The samples were divided into 3 groups: control, 1.23% APF gel, 5% NaF varnish. The specimen surfaces were observed by CLSM and measured average fluorescence of the lesion(AFL). The results were analyzed using one-way ANOVA and Pearson's correlation analysis at a significance level off 0.05(PSWA 18.0, SPSS Inc., USA). There were significant differences between AFL at baseline and 1 day after fluoride application(p<0.05) but there are no significant differences between ${\Delta}$ AFL of all groups (p=0.222). Result of Pearson's correlation analysis, there are no significant correlation between VHN and AFL, but there were significant correlation between AFL at baseline and 1 day after fluoride application(r=0.811, p<0.001). Although AFL decreased after fluoride application, but there was no difference between the groups. In the future, it is necessary to test the oral environment model or in situ experiment supplemented the limitations of this study.

AN EVALUATION OF CHEMICAL DEGRADATION OF LIGHT-CURED RESTORATIVE COMPOSITES (광중합 복합레진의 화학적 분해 평가)

  • Yang, Kuy-Ho;Kim, Hun-Ju;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.530-539
    • /
    • 2003
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Charisma, Filtek P 60, Palpique Estelite, and Spectrum. Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 2 weeks they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth(${\mu}m$) - measured SEM and CLSM from polished circular sections of exposed specimens. The results were as follows: 1. The sequence of mass loss was in descending order by Palpique Estelite, Filtek P 60, Charisma, and Spectrum. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek P 60, Charisma, Palpique Estelita, and Spectrum. 3. The sequence of the Si loss was in descending order by Chrisma, Spectrum, Palpique Estelite, and Filtek P 60. 4. The correlation coefficient between mass loss and degradation layer depth was relatively high(r=0.704, p<0.05). 5. When observed with SEM, destruction of bonding was observed between resin matrix and filler. 6. When observed with CLSM, degradation layer depth of composite resin surface was observed.

  • PDF

Study of Applicability for Removing Contaminants on Surface of Color Pigment Using the Laser Cleaning Technique -Focus on Analysis Method of Confocal Laser Scanning Microscope- (채색 안료 층의 표면오염물에 대한 레이저클리닝기법의 적용성 평가 연구 -공초점레이저주사현미경(CLSM)을 통한 분석평가 중심으로-)

  • Kim, Jin-Hyoung
    • Journal of Conservation Science
    • /
    • v.30 no.2
    • /
    • pp.123-136
    • /
    • 2014
  • Considering that decision in conservation treatment for damaged objects should consider not only various options of methodology of intervention but also possible consequences of different types of intervention, it is a difficult task to decide and propose clear and safest solution of preserving an object. In addition, it should be constantly challenged by conservators even if it is proved technique or methodology in a past treatment. Therefore, there is no absolute solution which can be applied to all practice but each decision can be different case by case. It is not possible to estimate the way how the present condition of material and environmental aspects would affect to the condition of an object in future. However if conservators keep trying to set out various ways of analysing pro and against effect of past treatments, it would be able to provide useful logics of proving efficiency and appropriateness of a certain treatment. Understanding that the advantage of laser technique is to adopt a way of cleaning an object without making a direct contact, which is different from other techniques, this paper aims at securing stability of laser techniques, although it remains a limitation in the compatibility to all other materials. This study has examined reacting process on the painted pigments against laser beam by using CLSM in order for it to display both the problems from such reacting process and the efficiency of it as a cleaning methodology. It has intended to estimate the result of laser techniques and propose the range of applicability.