• Title/Summary/Keyword: 공진 시험

Search Result 348, Processing Time 0.026 seconds

Nondestructive Interfacial Evaluation and Cure Monitoring of Carbon Fiber/Epoxyacrylate Composite with UV and Thermal Curing Using Electro-Micromechanical Technique (Electro-Micromechanical 시험법을 이용한 탄소 섬유 강화 에폭시아크릴레이트 복합재료의 자외선과 열경화에 따른 경화 모니터링 및 비파괴적 계면 평가)

  • 박종만;공진우;김대식;이재락
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.189-194
    • /
    • 2003
  • Interfacial evaluation, damage sensing and cure monitoring of single carbon fiber/thermo setting composite with different curing processes were investigated using electro-micromechanical test. After curing, the residual stress was monitored by measurement of electrical resistance and then compared to various curing processes. In thermal curing case, matrix tensile strength, modulus and interfacial shear strength were higher than those of ultraviolet curing case. The shrinkage measured during thermal curing occurred significantly by matrix shrinkage and residual stress due to the difference in thermal expansion coefficient. The apparent modulus measured in the thermal curing indicated that mechanical and interfacial properties were highly improved. The reaching time to the same stress of thermal curing was faster than that of UV curing case.

Application Study of Structural Strength Estimation by Measuring Velocity of Shear Wave (전단파 속도계측에 의한 구조물 강도추정 실용화 연구)

  • Park, Eunchurn;Choi, Jun-Seong;Lee, Han-Gu;Yoon, Jong-Ku
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.162-162
    • /
    • 2011
  • 표면파 속도 측정은 근래 토목분야에서는 비파괴 지반조사기법으로 활용되고 있다. 최근에는 디지털 신호처리기술의 발달과 함께, 더욱 정확해진 자료분석 알고리즘을 통하여 표면파 탐사관련 기술이 향상되어 3차원의 공간연속적인 시험이 가능해졌다. 본 연구는 표면파의 분산 특성을 이용하여 콘크리트 구조물의 깊이별 강성평가를 하는 SASW(Spectral Analysis of Surface Waves)기법과 STFT(Short time Fourier Transform)과 HWT(Harmonic Wavelet Transform)를 이용한 주파수영역에서의 공진주파수를 통한 부재평가 기법인 IE(Impact Echo)기법을 이용하여 대상부재의 강도평가를 수행하기 위한 시제품 개발을 수행하였다. 시제품은 메인프레임과 2개의 센서로 이루어져 측정을 수행하며 측정장치와 DAQ장치 및 S/W로 구성되어 있다. 메인프레임의 진동특성영향을 제거하기 위하여 2개의 센서는 프레임과 띄움구조로 설계하였고 센싱하는 위치는 대상 재료의 밀착되어 계측할 수 있도록 설계하였다. 탄성파를 계측하여 대상 재료의 깊이별 측정된 표면파의 속도를 계측하며 개발된 시제품의 구조물별 적용성 평가를 위한 실험을 수행하였고 평균 표면파 속도를 통해 추정한 콘크리트 두께와 결함 및 강도 추정의 적용성을 평가하였다. 시제품을 이용해 시험콘크리트 표면파를 측정한 결과 SASW기법을 이용하여 깊이에 대한 위상속도 분포와 IE기법의 결과로 개발된 시제품의 합리적 적용성이 평가되었다. 그러나 재료의 강도추정에 있어서는 각각 알고리즘의 주파수분석 요소들에 의해 변동되는 경향을 보여 추후 많은 테스트를 통해 속도-강도 추정의 회귀곡선식을 S/W에 탑재시키고 다양한 방법으로 조합하는 알고리즘으로 신뢰성있는 강도추정을 위한 알고리즘을 개발하여야 한다.

  • PDF

트랜스포머 열화 인자 도출 및 전원회로 영향성에 관한 연구

  • Lee, Yeong-Ju;Im, Hong-U;Han, Ji-Hun;Lee, Mu-Seok
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.61-70
    • /
    • 2011
  • 본 논문에서는 전원회로에 사용되는 주요 부품인 트랜스포머에 대한 주요한 고장모드, 고장메커니즘, 스트레스 인자들을 규정하고 그에 따른 가속열화시험을 실시하여 가장 유효한 스트레스 인자를 도출하고 트랜스포머의 열화가 전원회로에 미치는 영향을 분석에 대한 연구를 진행하였다. 전원회로의 고장분석에서, 트랜스포머의 일시적인 특성변화 또는 고장현상(Bunt, Short, Open 등) 발생으로 인한 전류의 급증, 공진주파수 부조화, Spike 발생 등으로 인한 주변부품 또는 구성회로에 미치는 영향을 정확하게 분석하는 것이 어렵다는 점과 비교적 단순한 구조와 강한 내성으로 뚜렷한 고장모드를 보이지 않는 특징으로 인해 전원회로의 고장원인이 트랜스포머 외의 반도체 소자, 저항, 커패시터 등에 의한 것으로 분석되는 것이 일반적이다. 유효한 스트레스 인자별 가속열화시험을 통한 성능평가에서는 절연저항을 제외한 특성에서는 뚜렷한 변화(열화)를 보이지 않았고, 고온고습에 의한 스트레스에서 가장 절연저항의 급격한 열화를 확인할 수 있었다. 또한 열화 각각의 스트레스 인자에 따라 열화시킨 트랜스포머를 실장하여 평가하는 실증적인 방법을 통해 분석한 결과 트랜스포머의 열화는 스위칭소자를 비롯한 주변부품에 스트레스를 가중시켜 발열로 대변되는 현상을 유발하고 트랜스포머 입출력 양단간의 위상편차는 심화시키는 것으로 나타났으며, 스트레스 인자 중 온습도에 의한 영향이 가장 유효하다는 것으로 확인할 수 있었다.

  • PDF

Performance Evaluation of Seismic Isolation using Ball Bearing (볼 베이링을 이용한 면진장치의 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok;Lee, Young-Seok;Yeo, Sang-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.71-74
    • /
    • 2011
  • 최근 국제적으로 지진 발생 규모가 증대하고 있으며, 우리나라를 비롯한 많은 나라에서 구조물 및 주요 시설물에 대한 내진설계에 관심이 증대되고 있다. 지진방재는 건물자체의 안전성뿐만 아니라 내부설비 및 소장품에 대한 안전성까지 종합적으로 검토되어야 하며 이를 위한 대책이 필요한 실정이다. 본 연구의 주요목적은 예측 불가한 자연재해인 지진에 대해 일반적인 면진성능을 갖는 기초격리장치로서의 기능을 충실히 수행할 수 있는지를 확인하기 위하여 면진장치를 사용한 구조물의 면진효과를 검증하는 것이다. 또한 설계된 스프링의 탄성계수에 따른 실제 지진 시 응답의 차이를 알아보기 위하여 공진실험 및 진동대 실험을 실시하여 면진테이블 시스템의 면진성능을 평가하였다. 진동대 실험은 미국 "NEBS Requirements"에서 규정하는 요구응답스펙트럼에 상응하는 임의 지진파를 적용하였고 각각 x축과 z축 가진 후, x-y-z 축을 동시에 가진하여 수행하였다. 시험응답스펙트럼(Test Response Spectrum)은 요구응답스펙트럼(RRS)에 포락하도록 시험하여 최대가속도는 x축 방향 가진 시 90%의 감쇠효과가 나타났으며, 3축 방향 가진 시 x축 방향은 58%, y축 방향은 31%의 감쇠효과가 나타났다. 최대상대변위는 설계스트로크 140mm에 대하여 최대 85.54mm의 변위가 발생하여 안정적인 거동을 나타내었다. 본 연구에서 제안한 면진테이블 시스템은 중요 첨단장비 및 문화재 등의 전도 및 파괴를 방지하는 데 효과적일 것으로 판단된다.

  • PDF

Experimental Study on the Effect of Particle Size Distribution of Soil on the Liquefaction Resistance Strength (입도분포가 액상화 저항강도에 미치는 영향에 관한 실험적 연구)

  • Seo Kyung-Bum;Choi Mun-Gyu;Kim Soo-Il;Park Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.7
    • /
    • pp.13-20
    • /
    • 2005
  • For experimental study on the effect of particle size distribution on the liquefaction resistance strength, particle size distribution curves of the dredged soil were investigated. In this process, four mean particle sizes and three uniformity coefficients were defined representatively and twelve representative particle size distribution curves which have different mean particle size and uniformity coefficient, were defined and manufactured by using the real dredged river soil. Cyclic triaxial tests and resonant column tests were carried out to analyze the effect of mean particle size and uniformity coefficient on the liquefaction resistance strength and dynamic characteristics.

Optimized Synthetic Making Test Facilities for Estimating the Making Performance of Circuit Breaker (차단기의 투입성능 평가를 위한 최적 합성투입시험설비)

  • Suh Yoon-Taek;Kim Maeng-Hvun;Song Won-Pyo;Koh Hee-Seog;Park Seung-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.284-292
    • /
    • 2005
  • Because all of the short-circuit testing laboratories have the limitation of test facilities, the synthetic making test methods have been used to estimate the short-circuit making performance of the ultra high-voltage circuit breaker as the alternative to direct test methods. So, KERI(Korea Eelctrotechnology Research institute) has completed the construction of the synthetic making test facilities using the low capacity step-up transformer method which fulfill the requirements specified in newly revised IEC 62271-100 Edition 1.1(2003) and have the testing capability up to 550kV, 63kA full-pole circuit breaker. The test facilities using the low capacity step-up transformer method presented in this paper are made up of the unit equipments such as HCS(High-speed Closing Switch), ITMC(Initial Transient Making Current) circuit and UP TR(low capacity step-up transformer) and have the operating range of 17.6$^{\circ}$ $\~$ 145.1$^{\circ}$ for testing the circuit breaker rated on up to 50kA and 43.1$^{\circ}$ $\~$ 119.6$^{\circ}$ for more than 50kA.

FDTD Analysis of the Mutual Coupling Between Closely Placed IFAs (근접한 IFA 사이의 신호결합에 대한 FDTD 해석)

  • Ji, Ki-Man;Lee, Soo-Jin;Chung, Eui-Seung
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.106-115
    • /
    • 2010
  • Because of space limitations, interferences between antennas of the KSLV-I communication systems occur and their effects become worse during all sorts of tests such as the flight test using a light plane. In this paper, coupled signal magnitude is calculated using the FDTD method. The theory of the FDTD, absorbing boundary condition, source input technique, and post processing of data are explained. The calculated coupling factor between two IFAs, which have 2 GHz resonance frequency and placed 5 cm apart, is -12.7 dB. Applied coupling calculation method can be effectively used for KSLV-I performance analysis, subsystem design, antenna arrangement, and communication link budget for the next space launch vehicle.

A study on the Structural Stability about the Fan Blade by the Air Excited Forces. (공기 가진력에 의한 팬 블레이드 구조 안정성 평가에 관한 연구)

  • 정규강;김경희;조생현
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.93-101
    • /
    • 2000
  • In a gas-turbine engine, fan blades in flow path are confronted with many kinds of loading. The study of the excited force by the wake of struts has proposed and the possibility of fatigue failure about rotating fan blades by the excited force at the steady state is evaluated. Equations of the excited force of wakes has been derived at the steady state and the maximum pressure distributions measured at the transient state are proposed. Dynamic characteristics and the fatigue strength of fan blades by experimental test were obtained. To evaluate HCF(High Cycle Fatigue) damage of fan blades, FEM analysis was performed with a steady state harmonic response, which was followed by high cycle fatigue damage factor from goodman diagram.

  • PDF

Nonlinear Dynamic Properties of Fiber Reinforced Soils (섬유혼합토의 비선형 동적물성치)

  • 박철수;황선근;목영진
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.189-197
    • /
    • 2003
  • In this paper, deformation characteristics of fiber-mixed-soils were studied at small strain range(0.0001%~1%) using resonant column test and triaxial test, and reinforcement effect was evaluated by the measure of maximum shear moduli. The effects of the major parameters such as fiber content, aspect ratio and fiber type on reinforcement were comparatively assessed. The specimens were remolded from Jumunjin Sand randomly mixed with discrete polypropylene staple fibers. Maximum shear moduli of fiber-mixed-soils increased by up to 30% and modulus reduction was also restrained in nonlinear range. Shear moduli increased as the aspect ratio increases. The reinforcement was more effective with fibrillated fiber than with monofilament fiber. The most effective reinforcement was achieved with the specimen of 0.3 % fiber content.

Curing Characteristics of Controlled Low Strength Material Made with Coal Ashes (석탄회를 사용한 저강도 고유동화재의 경화 특성 분석)

  • Kim, Juhyong;Cho, Samdeok;Kong, Jinyoung;Jung, Hyuksang;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.11
    • /
    • pp.77-85
    • /
    • 2010
  • Unconfined compressive strength tests were performed to evaluate curing characteristics of controlled low strength material(CLSM) made with coal ashes. It is found that unconfined compressive strength normalized by curing times, increases as decreasing the water contents of CLSM particularly during first three days. Dynamic cone penetrometer tests were also carried out to evaluate cost-effective CLSM lump strength characteristics with time. It takes around 10 days to reach target strength, 500kPa (penetration rate, 20mm/blow). Curing rate significantly decreases after 10 days elapsed regardless of CLSM formulation.